FI (list display)

  • H02B1/00
  • Frames, boards, plates, desks, cases; details of substations or switchgears [5] HB CC 5G016
  • H02B1/01
  • .Frameworks [5] HB CC 5G016
  • H02B1/01@A
  • related to structure and combination of frames, e.g. connection between boards HB CC 5G016
  • H02B1/01@B
  • related to a channel base HB CC 5G016
  • H02B1/01@Z
  • Others HB CC 5G016
  • H02B1/015
  • .Boards, panels, desks; parts thereof or accessories therefor [5] HB CC 5G016
  • H02B1/015@A
  • related to the material, e.g. foamed resin or composite plate HB CC 5G016
  • H02B1/015@Z
  • Others HB CC 5G016
  • H02B1/03
  • ..for energy meters [5] HB CC 5G016
  • H02B1/04
  • ..Mounting thereon of switches or of other devices in general, the switch or device having, or being without, casing HB CC 5G016
  • H02B1/04@A
  • related to mounting of members such as switches, e.g. related metal pieces (fuses H02B 1/18, current transformers H02B 1/04F) HB CC 5G016
  • H02B1/04@C
  • related to mounting bodies or unit panels with multiple different switches HB CC 5G016
  • H02B1/04@D
  • related to mounting on mosaic panels (H02B 15/04 takes precedence) HB CC 5G016
  • H02B1/04@E
  • characterised by mounting metal pieces (H02B 1/04A, C take precedence) HB CC 5G016
  • H02B1/04@F
  • related to instrument transformers HB CC 5G016
  • H02B1/04@Z
  • Others HB CC 5G016
  • H02B1/044
  • ...Mounting through openings [5] HB CC 5G016
  • H02B1/048
  • ....Snap mounting [5] HB CC 5G016
  • H02B1/052
  • ...Mounting on rails [5] HB CC 5G016
  • H02B1/056
  • ...Mounting on plug boards [5] HB CC 5G016
  • H02B1/06
  • ..having associated enclosures, e.g. for preventing access to live parts [1, 2006.01] HB CC 5G016
  • H02B1/14
  • .Shutters or guards for preventing access to contacts (shielding of isolating-contacts in withdrawable switchgear H02B 11/24) HB CC 5G016
  • H02B1/14@A
  • related to external switching operations such as by breakers or fuses HB CC 5G016
  • H02B1/14@Z
  • Others HB CC 5G016
  • H02B1/16
  • .Earthing arrangements (earthing arrangements for substations H02B 5/01; earthing arrangements for switchgear H02B 11/28, H02B 13/075) [1, 5, 2006.01] HB CC 5G016
  • H02B1/16@A
  • related to drawer type grounding arrangements HB CC 5G016
  • H02B1/16@B
  • related to gas insulating switches (H 02B 13/00 to 13/06 take precedence) HB CC 5G016
  • H02B1/16@Z
  • Others HB CC 5G016
  • H02B1/18
  • .Disposition or arrangement of fuses (for a switchgear having a withdrawable cart H02B 11/24) HB CC 5G016
  • H02B1/18@B
  • related to fuses HB CC 5G016
  • H02B1/18@C
  • related to gas insulating switches (H02B 13/00 to 13/08 take precedence) HB CC 5G016
  • H02B1/18@Z
  • Others HB CC 5G016
  • H02B1/20
  • .Bus-bar or other wiring layouts, e.g. in cubicles, in switchyards (installations of bus-bars H02G 5/00) HB CC 5G016
  • H02B1/20@A
  • related to bus or cable layouts HB CC 5G016
  • H02B1/20@B
  • .Units engaging vertical bus (H02B 1/14 takes precedence for shutters.) HB CC 5G016
  • H02B1/20@C
  • .related to insulating structures, e.g. including insulation supports or barriers (H02B 1/20G takes precedence) HB CC 5G016
  • H02B1/20@D
  • .related to engagements or couplings between freely attached or detached buses, bus and equipment, e.g. coupling between facing parts (engagements with fuses H02B 1/18) HB CC 5G016
  • H02B1/20@E
  • .related to mechanical couplings between buses, or bus and equipment, e.g. using connecting pieces or bolts HB CC 5G016
  • H02B1/20@F
  • .related to ducts HB CC 5G016
  • H02B1/20@G
  • .related to penetrations on walls or floors (H02B 1/20D takes precedence, H02B 1/28A takes precedence for dustproof structures, H02B 1/28J takes precedence for fireproof structures) HB CC 5G016
  • H02B1/20@H
  • .related to shapes of buses or cables, or optimum arrangements thereof HB CC 5G016
  • H02B1/20@L
  • .Others HB CC 5G016
  • H02B1/20@M
  • related to layout of wiring HB CC 5G016
  • H02B1/20@N
  • .related to supporting or guiding HB CC 5G016
  • H02B1/20@P
  • ..using dusts HB CC 5G016
  • H02B1/20@Q
  • .using wiring plates (wiring methods H02B 3/00E) HB CC 5G016
  • H02B1/20@R
  • .related to jumper wires at moving portions, e.g. door hinges or flexible conductors HB CC 5G016
  • H02B1/20@S
  • .related to terminal board structures or mounting arrangements HB CC 5G016
  • H02B1/20@T
  • ..Socket terminal boards, e.g. connector terminals HB CC 5G016
  • H02B1/20@Z
  • Others HB CC 5G016
  • H02B1/21
  • ..Bus-bar arrangements for rack-mounted devices with withdrawable units [5] HB CC 5G016
  • H02B1/22
  • ..Layouts for duplicate bus-bar selection HB CC 5G016
  • H02B1/22@A
  • related to switching arrangements by mechanical operations of breakers HB CC 5G016
  • H02B1/22@B
  • related to switching arrangements by moving breakers HB CC 5G016
  • H02B1/22@Z
  • Others HB CC 5G016
  • H02B1/24
  • .Circuit arrangements for boards or switchyards [1, 2006.01] HB CC 5G016
  • H02B1/26
  • .Casings; Parts thereof or accessories therefor [5, 2006.01] HB CC 5G016
  • H02B1/28
  • ..dustproof, splashproof, drip-proof, waterproof or flameproof [5] HB CC 5G016
  • H02B1/28@A
  • related to prevention against dust, corrosion and insects HB CC 5G016
  • H02B1/28@B
  • .Sealing structure, e.g. doors provided with packing HB CC 5G016
  • H02B1/28@C
  • .using filters HB CC 5G016
  • H02B1/28@D
  • related to waterproof, damp-proofing (H02B1/28A takes precedence) HB CC 5G016
  • H02B1/28@E
  • .drip-proof structure, e.g. blind windows or eaves HB CC 5G016
  • H02B1/28@F
  • .condensation prevention structure, e.g. using heaters or dehumidifying materials HB CC 5G016
  • H02B1/28@G
  • related to pressure relief devices HB CC 5G016
  • H02B1/28@H
  • related to sound-proof devices HB CC 5G016
  • H02B1/28@J
  • related to fire protection devices HB CC 5G016
  • H02B1/28@K
  • .with digestants HB CC 5G016
  • H02B1/28@L
  • related to explosion-proof devices HB CC 5G016
  • H02B1/28@M
  • related to gas-insulated switchgear (H02B13/00 to 13/08 take precedence) HB CC 5G016
  • H02B1/28@Z
  • Others HB CC 5G016
  • H02B1/30
  • ..Cabinet-type casings; parts thereof or accessories therefor [5] HB CC 5G016
  • H02B1/30@A
  • combination and connection between framework and plates HB CC 5G016
  • H02B1/30@B
  • combination and connection between plates HB CC 5G016
  • H02B1/30@C
  • related to structure and mounting of panel sheets and ornamental panels HB CC 5G016
  • H02B1/30@D
  • related to mounting of switches and switch covers and optimized arrangement of switches HB CC 5G016
  • H02B1/30@E
  • related to structure and mounting of protection covers, blind plates, card holders, in-board inspection windows HB CC 5G016
  • H02B1/30@F
  • characterised by structure of boxes, per se, e.g. materials, roofs, inside partitions HB CC 5G016
  • H02B1/30@G
  • related to row board structure HB CC 5G016
  • H02B1/30@H
  • related to castings in different shapes, a group of boxes and equipment and castings, connection with boxes, e.g. facilities for spot network power distribution HB CC 5G016
  • H02B1/30@J
  • related to stand type distribution boards HB CC 5G016
  • H02B1/30@K
  • related to desk type control panels HB CC 5G016
  • H02B1/30@L
  • related to underwater or in-oil distribution boards HB CC 5G016
  • H02B1/30@Z
  • Others HB CC 5G016
  • H02B1/32
  • ...Mounting of devices therein [5] HB CC 5G016
  • H02B1/32@A
  • Mounting of devices on supporting members HB CC 5G016
  • H02B1/32@B
  • .Supporting members rotating HB CC 5G016
  • H02B1/32@C
  • Arrangement or mounting of parts inside the unit case, e.g. layout of equipment, small switches in unit cases, castings HB CC 5G016
  • H02B1/32@Z
  • Others HB CC 5G016
  • H02B1/34
  • ....Racks [5] HB CC 5G016
  • H02B1/34@A
  • related to mounting of devices on shelf plates HB CC 5G016
  • H02B1/34@Z
  • Others HB CC 5G016
  • H02B1/36
  • .....with withdrawable units [5] HB CC 5G016
  • H02B1/38
  • ...Hinged covers or doors [5] HB CC 5G016
  • H02B1/38@A
  • related to doors (doors provided with packing H02B1/28B; arrangements for maintenance, inspection H02B3/00K) HB CC 5G016
  • H02B1/38@B
  • .related to supporting members, e.g. arrangements of stoppers at hinges HB CC 5G016
  • H02B1/38@C
  • .mounting of electrical parts inside HB CC 5G016
  • H02B1/38@D
  • .related to a handle or an operating rod connected to the handle, a locking device HB CC 5G016
  • H02B1/38@Z
  • Others HB CC 5G016
  • H02B1/40
  • ..Wall-mounted casings; parts thereof or accessories therefor [5] HB CC 5G211
  • H02B1/40@A
  • Distribution board HB CC 5G211
  • H02B1/40@B
  • .Castings (H02B1/40E takes precedence) HB CC 5G211
  • H02B1/40@C
  • ..Mounting to walls HB CC 5G211
  • H02B1/40@D
  • .Connection, terminal areas HB CC 5G211
  • H02B1/40@E
  • .Heat resistant distribution boards HB CC 5G211
  • H02B1/40@Z
  • Others HB CC 5G211
  • H02B1/42
  • ...Mounting of devices therein [5] HB CC 5G211
  • H02B1/44
  • ...Hinged covers or doors [5] HB CC 5G211
  • H02B1/46
  • ..Boxes; Parts thereof or accessories therefor [5] HB CC 5G016
  • H02B1/48
  • ...Mounting of devices therein [5] HB CC 5G016
  • H02B1/50
  • ..Pedestal- or pad-mounted casings; parts thereof or accessories therefor [5] HB CC 5G016
  • H02B1/52
  • ..Mobile units, e.g. for work sites [5] HB CC 5G016
  • H02B1/52@A
  • related to fully equipped transportable type HB CC 5G016
  • H02B1/52@Z
  • Others HB CC 5G016
  • H02B1/54
  • .Anti-seismic devices or installations [5, 2006.01] HB CC 5G016
  • H02B1/56
  • .Cooling; ventilation [5] HB CC 5G016
  • H02B1/56@A
  • related to cooling methods or ventilation HB CC 5G016
  • H02B1/56@B
  • .related to indirect cooling methods HB CC 5G016
  • H02B1/56@Z
  • Others HB CC 5G016
    TOP