F-Term-List

5G016 Patch boards
H02B1/00 -1/38@Z;1/46-7/08
H02B1/00-1/38;1/46-1/56 AA AA00
TYPES
AA01 AA02 AA03 AA04 AA06 AA07 AA09
. Distribution boards and unit boards . . Open boards (e.g., racks) . . Boards that form box units (e.g., one face of the storage unit forms an exterior wall) . . . Closed boards (e.g., doors on the board side) . Aggregate boards . . Compound boards that are installed side by side . Instruments, or composite bodies composed of instruments and boards
H02B1/54 BA BA00
ANTI-SEISMIC STRUCTURES
BA01 BA02 BA04 BA05 BA06 BA08
. Structure of the interior board (e.g., wall sections) . . Use of reinforcing materials . Exterior board structures . . Addition of reinforcement materials . . . Affixing of reinforcement materials to floors, walls, or the like . Others
H02B1/01@B BB BB00
BASES OF PATCH BOARDS
BB01 BB03 BB05 BB07
. Buried types . Half-buried types . Floor types . Others
H02B1/30@A;1/30@B;1/30@Z CA CA00
STRUCTURE OF PATCH BOARDS PRODUCED BY COMBINING FRAMEWORKS AND PLATES
CA01 CA02 CA03 CA05 CA06 CA07 CA09 CA10
. Framework . . Connection units (e.g., shape or fixing means) . . . Use of connection elements (e.g., corner members) . Framework and plates . . Connection units (e.g., shape or fixing means) . . . Use of connection elements (e.g., corner members) . Plates . . Special structures (e.g., double plates or nonmetal plates)
CA11 CA12 CA13 CA15
. . Connection units (e.g., shape or fixing means) . . . Use of connection elements . . . Fixing means other than bolts and nuts (e.g., welding or engaging) . Standardization
H02B1/30@C;1/30@F;1/30@Z CB CB00
OVERALL STRUCTURES OF PATCH BOARDS (I.E., FINISHED PRODUCTS)
CB01 CB03 CB05 CB07 CB09
. Special structures and roofs for board units . Materials and characteristics thereof . Wall plates that are removable (e.g., for inspection or adjustment) . Secondary wall plates (e.g., decorative plates or covers) . Attachment to structures such as walls (i.e., excluding bases)
H02B1/28@B;1/28@G;1/38@A;1/38@B;1/38@D;1/38@Z CC CC00
DOORS
CC01 CC02 CC03 CC04 CC05 CC07 CC08 CC09 CC10
. Shapes, structures, and mechanisms for opening and closing . . Sealed types (e.g., use of packing materials) . . Means for tightening or holding the doors closed . . Doors that open both to the left and right . . Mechanisms for opening and closing other than double doors . Support units . . Hinges . . Pins . . Removable sections
CC11 CC13 CC15 CC17 CC19 CC20
. . Telescopically adjustable units . Stoppers or guides (e.g., between adjacent doors) . Operating units . Pressure-release mechanisms . Locking . . Interlocking
CC21 CC22 CC23 CC24
. . . Interlocking between the disconnectors and switches . . . . Mechanical means (e.g., linking mechanisms) . . . . Electrical means (e.g., circuit constructions) . . . Use of handles or operating units
H02B1/04@A;1/04@C;1/04@E;1/04@Z;1/044-1/056;1/32@A;1/32@Z;1/36 CD CD00
MOUNTING OF ELECTRICAL DEVICES
CD01 CD02 CD03 CD04 CD05 CD06 CD07 CD08 CD10
. Component units (e.g., switches) . . Mounting of units on circuit boards . . . Pass-through support . . . . Clamp support . . . . Elastic support . . . . Passing through parts of terminals or operating units . . Mounting on supports or frames . . Mounting on bases other than plates or supports . . Mounting of covers, decorative plates, or the like
CD12 CD14 CD16
. . Mounting using stud-like terminals (e.g., circuit breakers) . . Mounting in buried boxes . . Optimal arrangements (e.g., on boards or inside units)
CD21 CD22 CD23 CD24 CD25 CD26 CD27
. Units, panel plates, or large instruments . . Form of mounting . . . Fixed types . . . . Mounting on frames or frameworks . . . . Mounting means . . . Movable types (e.g., drawer types) . . . . Guide or fastening means
CD32 CD33 CD34 CD35 CD36 CD37 CD38
. . Mounting location . . . Front of boards . . . Middle of boards . . . Rear of boards or perimeter walls . . . Bottom of boards . . . Shelf units . . . Optimum arrangements (i.e., layout)
H02B1/16@A;1/16@Z CE CE00
GROUNDING DEVICES
CE01 CE02 CE03 CE04 CE05 CE06 CE07 CE08 CE10
. Grounding devices inside the boards . . Grounding using drawer devices . . . Dual use as a bus-line or as a load . . . Use of moving terminals . . Grounding using built-in equipment . . . Built-in equipment that interlocks with housing equipment . . . Use of manual operation . . Locking (e.g., interlocking) . Outside of boards or equipment other than boards
H02B1/14@A;1/14@Z;1/20@B;1/38@D CF CF00
SAFETY DEVICES, PROTECTION DEVICES, OPERATING MECHANISMS, AND PREVENTION OF ELECTRIC SHOCK
CF01 CF02 CF03 CF05 CF07
. Operating mechanisms for the equipment inside the boards . . Operation from outside of boards . . . Disconnectors, switches, or fuses . . Operation from within the boards . . Locking (e.g., interlocking)
CF11 CF12 CF13 CF14 CF15
. Prevention of contact between live wires . . Use of shutters, protective plates, or shield plates . . . Paired bus lines . . . . Paired disconnectors or bushings . . . . Units for engaging vertical bus bars and drawer devices
H02B1/20@G;1/28@A-1/28@F;1/38@A;1/38@B;1/56@A-1/56@Z CG CG00
VENTILATION
CG01 CG02 CG03 CG04 CG05 CG06 CG07 CG08 CG09 CG10
. Ventilation and cooling . . Direct cooling . . . Structure of the intake units . . . . Forced-intake devices (e.g., fans) . . . . Splash-proof or drip-proof structures . . . . Dustproof structures . . . . . Filters . . . Structure of exhaust units . . . . Forced-exhaust devices (e.g., fans) . . . . Splash-proof or drip-proof structures
CG12 CG13 CG14 CG15 CG17 CG18 CG19
. . . . Dustproof structures (e.g., filters) . . . Airflow channel layout (e.g., guide plates) . . . . Multilayer distribution boards . . . . . Compartments for bus-line . . Indirect cooling . . . Use of heat pipes . . . Use of heat radiation fins
CG21 CG22 CG23 CG24 CG26
. Water-proofing, corrosion-proofing, insect-proofing, or dust-proofing . . Units for opening and closing of boards . . . Seal structures . . . . Using packing . . Parts that pass through (e.g., bus-lines, cables, or wiring)
CG31 CG32 CG33 CG34 CG36
. Prevention of condensation . . Use of heating devices . . . Use of an electric heating device (e.g., sensors) . . . Use of heated pipes . . Use of hygroscopic materials (e.g., desiccants)
H02B1/28@G;1/38@D CH CH00
PRESSURE-RELEASE APPARATUSES
CH01 CH02 CH03 CH05 CH07 CH09
. Open types . . Use of pressure-release paths inside boards . . Plates for guiding the direction of pressure release or for protection . Re-closing types . Closed types . Coordinated breakage (e.g., a part of a wall is made weak)
H02B1/14@Z;1/20@B-1/20@L;1/30@G;1/30@H DA DA00
BUS BARS, BUS LINES, AND CABLES (I.E., POWER LINES)
DA01 DA02 DA03 DA04 DA05 DA06 DA08 DA10
. Insulation and support . . Direct insulation and support of bus bars . . . Parallel arrangement of bus bars . . . . Support of bus bars by clamping . . . Connection units or branch units . . . Elements that pass through walls or the like . . Indirect insulation of the bus bar (e.g., shield plates or barriers) . . Cables
DA12
. . . Cables that pass through walls or floors
DA21 DA22 DA23 DA24 DA25 DA26 DA28 DA29 DA30
. Connection . . Mechanical connection (i.e., excluding connectors) . . . Axial connection . . . . Use of connection elements . . . Connection of branch units . . . . Connection of branch units for cabinet panels . . Connection using connectors . . . Disconnect bushings (e.g., connectors between paired instruments) . . . Connectors for parallel boards
DA31 DA32 DA34 DA35 DA37
. Connection of equipment in a direction perpendicular to the bus bars . . Engagement on one side . . Engagement on two sides . . . Use of the bus bar for engagement . . Shape of the engagement unit of the bus bar (e.g., U-shaped or stacked)
DA41 DA42 DA43 DA45
. Ducts . . Ducts between composite parallel boards . . . Gate-type boards . . Ducts between separate boards or between boards and equipment
DA51 DA52 DA54
. Optimal arrangements . . Layouts of bus bars . . Layouts of cables
H02B1/20@N;1/20@P;1/20@S;1/20@T;1/20@Z DB DB00
SUPPORT, GUIDANCE, AND OPTIMAL ARRANGEMENT OF IN-BOARD CONTROL WIRING
DB01 DB02 DB03 DB04 DB05 DB06 DB08
. Support and guidance . . Use of a tightening means (e.g., bands) . . Ducts . . . Attachment of ducts . . . Connection of ducts with other units . . . Using in-board constituent members . . Optimal arrangements (i.e., layout)
DC DC00
TERMINAL DEVICES FOR IN-BOARD CONTROL WIRING
DC01 DC02 DC03 DC04 DC06 DC07 DC08 DC10
. Terminals that are mechanically connected (i.e., excluding connectors) . . Planar arrangements . . Three-dimensional layouts . . Optimal arrangements (e.g., individual terminals or entire terminal devices) . Connections using connectors . . Terminals of modular equipment . . Intermediate terminals (e.g., socket terminals) . Standardization
H02B1/30@G;1/30@H;1/30@Z EA EA00
COMPOSITE BODIES OF PARALLEL COMPOSITE BOARDS AND OF BOARDS AND EQUIPMENT
EA01 EA02 EA03 EA04 EA05 EA07 EA08
. Boards with the same shape . . Boards without border walls . . . Structure of the connection element (e.g., joining means) . . Boards with border walls . . . Structure of the connection element (e.g., joining means) . Composite bodies composed of boards having different shapes or of boards and equipment . . Arrangements on the same base