ReturnTo Theme-Group-Choice | Onelevelup |
(Not Translated)
5K048 | Selective calling equipment (for remote control and measurement) | |
H03J9/00 -9/06;H04Q9/00-9/16 |
H03J9/00-9/06;H04Q9/00-9/16 | AA | AA00 PURPOSE |
AA01 | AA02 | AA03 | AA04 | AA05 | AA06 | AA07 | AA08 | AA09 | AA10 |
. Concentration of wiring | . Standardization; Sharing of standards | . Downsizing of apparatuses | . Improvement of operability | . Automation | . Improvement of reliability | . . Redundancy | . Speed increase | . Malfunction prevention | . Improvement of beauties or designs | |||
AA11 | AA12 | AA13 | AA14 | AA15 | AA16 | |||||||
. Facilitating manufacture | . Loss prevention of remote-control transmitters | . Sharing operation parts (1:N structures) | . Multifunctional structures, consolidation with functions other than remote-control | . Improvement of security | . Power saving | |||||||
BA | BA00 APPLICATION |
BA01 | BA02 | BA03 | BA04 | BA05 | BA06 | BA07 | BA08 | BA09 | BA10 | |
. Devices for household use | . . Audio, video devices | . . . Television, video cassette recorders | . . . . Advance remote recording | . . . Radios | . . . Composite apparatuses (component stereophones, stereophones) | . . Lightening apparatuses | . . Air conditioners | . . Toys | . . Optical instruments, cameras | |||
BA11 | BA12 | BA13 | BA14 | |||||||||
. . Timepieces | . . Home automation | . . Remote-control by telephones | . . Baths, boilers | |||||||||
BA21 | BA22 | BA23 | BA24 | BA25 | BA26 | BA27 | BA28 | BA29 | BA30 | |||
. Industrial apparatuses | . . For power stations, substations | . . For plants | . . . Data loggers | . . For machine tools | . . For physical distribution machines | . . For traffic control | . . . Railways | . . . Roads | . . For controlling the volumes of water, the levels of water | |||
BA31 | BA32 | BA34 | BA35 | BA36 | BA37 | |||||||
. . For communication facilities | . . Devices for power distribution | . Data collection | . Telemetry, telemeters | . . Remote meter inspection for home use | . . Remote meter inspection for industrial use | |||||||
BA41 | BA42 | BA43 | BA44 | BA45 | BA46 | BA47 | BA48 | |||||
. Moving bodies | . . Automobiles | . . Electric trains | . . Ships | . . Airplanes | . . For spacecrafts | . . Elevators | . . Unmanned vehicles | |||||
BA51 | BA52 | BA53 | BA54 | BA55 | ||||||||
. Building maintenance apparatuses | . Keys | . . Passwords | . . Unauthorized use prevention apparatuses | . . Room access control | ||||||||
CA | CA00 SELECTION SYSTEMS |
CA01 | CA02 | CA03 | CA04 | CA05 | CA06 | CA07 | CA08 | |||
. Cyclic system | . Random systems | . Polling | . Interruption | . Priority transmission | . General calling | . Group calling | . Program calling | |||||
CA11 | CA12 | CA13 | CA14 | CA15 | CA16 | |||||||
. Magnitude of voltage or current | . Polarity discrimination | . Frequencies | . . Multifrequencies in series | . . Multifrequencies in parallel | . No address | |||||||
CB | CB00 MULTIPLEX SYSTEMS |
CB01 | CB02 | CB03 | ||||||||
. Time-division multiplexing | . Frequency-division multiplexing | . Composites | ||||||||||
DA | DA00 SYSTEM STRUCTURES |
DA01 | DA02 | DA03 | DA05 | DA06 | DA07 | DA08 | DA09 | |||
. 1:1 | . 1:N | . M:N | . Buses (multi-drops) | . Loops | . Hierarchical systems | . Group structures | . Series (subordinates) | |||||
DB | DB00 TRANSMISSION MEDIA |
DB01 | DB02 | DB03 | DB04 | DB05 | DB06 | DB07 | ||||
. Radio waves | . Light | . . Visible light | . . Infra-red radiation | . Sound waves | . . Ultrasonic waves | . Compound | ||||||
DC | DC00 TRANSMISSION PATHS |
DC01 | DC02 | DC03 | DC04 | DC05 | DC06 | DC07 | DC08 | |||
. Wireless | . . Artificial satellites | . Lines | . . Exclusive signal lines | . . Coaxial cables | . . Power lines | . . Telephone lines | . . Optical fibers | |||||
EA | EA00 MODES OF SIGNALS |
EA01 | EA02 | EA03 | EA04 | EA05 | EA06 | |||||
. Pulse signals | . . Pulse frequencies | . . Pulse width | . . Pulse phases | . . Number of pulses | . . Positions and intervals of pulses | |||||||
EA11 | EA12 | EA13 | EA14 | EA15 | EA16 | EA17 | EA18 | |||||
. Code signals | . . Production of code signals | . . Decoding of code signals | . . Transmission formats of code signals | . . Parallel transmission of code signals | . . Coincidence detection of code signals | . Bar code signals | . PCM | |||||
EA21 | EA22 | EA23 | ||||||||||
. Magnitude of voltage or current, multi-value signals | . Polarity | . Frequencies | ||||||||||
EB | EB00 CONTENTS OF SIGNALS |
EB01 | EB02 | EB03 | EB04 | EB05 | EB06 | EB07 | EB08 | EB09 | EB10 | |
. Address signals | . Control signals | . Return-send signals | . Synchronization signals | . Clock signals | . Set value signals | . Indication signals | . Trouble signals | . Reset signals | . Measured value signals | |||
EB11 | EB12 | EB13 | EB14 | EB15 | ||||||||
. Time data signals | . Status signals of devices | . Status change signals | . Voice signals | . Video signals | ||||||||
FA | FA00 TRANSMISSION CONTROL |
FA01 | FA02 | FA03 | FA04 | FA05 | FA06 | FA07 | FA08 | FA09 | FA10 | |
. Send back collation | . Successive transmission collation | . Decision by majority | . Continuous repetition by N times | . Parity checks | . Testing a determined number of pulses | . Predetermined time, period tests | . Other error checks | . Error checks by noise detection | . Re-transmission requests | |||
FA11 | ||||||||||||
. Correcting errors | ||||||||||||
FB | FB00 INDICATION |
FB01 | FB02 | FB03 | FB04 | FB05 | FB06 | FB07 | FB08 | FB09 | FB10 | |
. Digital indication | . Analog indication | . Position indication | . Trouble indication | . Operation status indication | . Power supply indication | . . Indication of power supply consumption | . Data indication | . Measured value indication | . Operation guidance, instruction indication | |||
FB11 | FB12 | FB13 | FB15 | FB16 | FB18 | |||||||
. Indication by sounds | . . Voice synthesis | . . . Voice synthesis by ROM | . Indication of remote-control operation units | . Multi-colored indication | . Lightening of operation parts | |||||||
FC | FC00 CONTROL |
FC01 | FC02 | FC03 | FC04 | FC05 | ||||||
. Program control | . . Sequence programmers | . Timer control | . Feedback control | . Programming by transmitters | ||||||||
GA | GA00 IMPROVEMENT OF RELIABILITY |
GA01 | GA02 | GA03 | GA04 | GA05 | GA06 | GA07 | GA08 | GA09 | GA10 | |
. Parallel transmission of the same signals | . Redundant structures | . . Parallel operations | . . Hot reserves | . . Diversity | . . In-use, reserves | . Two-behavior operations | . Switching of remote control, direct control | . Having fail-safe functions | . Backing up of control data | |||
GA11 | GA12 | GA13 | GA14 | GA15 | ||||||||
. Objects of redundancy | . . Main stations (transmitters) | . . Substations (receivers) | . . Transmission paths | . . Transmission media | ||||||||
GB | GB00 MONITORING, TESTING, MAINTENANCE |
GB01 | GB02 | GB03 | GB04 | GB05 | GB06 | GB07 | GB08 | GB10 | ||
. Operation testing | . Indication inversion testing | . Self-diagnosis | . Simulation | . Fault detection | . . Power failure detection | . . Multiple selection detection | . . Trouble detection of apparatuses | . Initialization at the time of power restoration (turning on) | ||||
GC | GC00 OPERATIONS |
GC01 | GC02 | GC03 | GC04 | GC05 | GC06 | |||||
. Changes of data | . . Setting, changes of addresses | . . Changes of set values | . . Replacement of ROMs | . . Rewriting of memories | . . Learning functions | |||||||
HA | HA00 COMPONENTS |
HA01 | HA02 | HA03 | HA04 | HA05 | HA06 | HA07 | ||||
. Main stations | . Substations | . Relay stations | . Transmitters | . . Transmission parts, light emission parts | . Receivers | . . Receiving parts, light receiving parts | ||||||
HA11 | HA12 | HA13 | HA14 | HA15 | HA16 | HA17 | HA18 | HA19 | HA20 | |||
. Stationary shapes, structures, circuits | . . Structures for storing, attaching and detaching of remote controllers | . . Keyboards | . . . Key matrixes | . . . Diode matrixes | . . Encoders | . . Decoders | . . Selection relay | . . Integrated circuits | . . Monitor boards | |||
HA21 | HA22 | HA23 | HA24 | |||||||||
. Indication parts (indication elements) | . . CRT | . . Liquid crystals | . . Light emitting diodes | |||||||||
HA31 | HA32 | HA33 | HA34 | HA35 | HA36 | HA37 | HA38 | HA39 | ||||
. Power supplies | . . Remote supply of power supplies | . . Automatic interruption | . . Monitor parts of power supplies | . . Reserve power supplies | . . Charging types | . . . Batteries | . . . Capacitors | . . Solar cells |