ReturnTo Theme-Group-Choice | Onelevelup |
5H730 | DIRECT CURRENT-DIRECT CURRENT (DC-DC) CONVERTERS | |
H02M3/00 -3/44 |
H02M3/00-3/44 | AA | AA00 PURPOSE |
AA01 | AA02 | AA03 | AA04 | AA05 | AA06 | AA07 | AA08 | AA10 | |
. preventing noise | . . from generating | . . from mixing | . improving environmental resistance or precisions | . . Temperature compensation | . . by circuit configurations (AA05 takes precedence) | . . . Redundancy of elements or circuits | . . by mounting methods (AA05 takes precedence) | . improving switching speed or switching in high frequencies | ||||
AA11 | AA12 | AA13 | AA14 | AA15 | AA16 | AA17 | AA18 | AA19 | AA20 | |||
. Multi-functionalisation | . . Indication or monitoring | . . improving testing or maintenance | . improving conversion efficiency or reducing losses | . increasing capacity reducing size and weight or improving cost | . . by parallelising or dividing elements or circuits | . improving safety | . improving input power factors | . preventing biased magnetisation or saturated magnetisation of transformers or the like | . Protection of circuits or elements | |||
AS | AS00 APPLICATION |
AS01 | AS02 | AS03 | AS04 | AS05 | AS06 | AS08 | ||||
. Constant voltage power sources | . Constant current power sources | . Constant-power power sources | . High voltage or boosting power sources | . Bucking power sources | . No voltage conversion transformers for insulating purposes | . Reversible conversion power sources | ||||||
AS11 | AS12 | AS13 | AS14 | AS15 | AS16 | AS17 | AS18 | AS19 | ||||
. for lighting | . for heating | . for driving electric motors | . for electronic tubes | . . for cathode ray tubes (CRT) | . . for X-ray tubes | . for battery charging | . for strobes | . for electronic computers | ||||
AS21 | AS22 | AS23 | ||||||||||
. Uninterruptible power sources | . . Parallel operation | . . Standby operation | ||||||||||
BB | BB00 TYPE OF MAIN CONVERSION UNIT |
BB01 | BB02 | BB03 | BB04 | BB05 | BB06 | BB08 | BB09 | |||
. Charging and discharging conversion units i.e. series parallel switching | . . Boost types | . . Buck types | . . No voltage conversion types | . . Polarity changing types | . . Bi-directional types | . . using field effect transistors (FET) for electrical storage elements | . . using reactors for electrical storage elements | |||||
BB11 | BB13 | BB14 | BB15 | BB17 | BB18 | |||||||
. Non-insulated chopper systems | . . BUCK types | . . BOOST types | . . BUCK-BOOST types | . . CUK types | . . Non-insulated SEPIC types | |||||||
BB21 | BB22 | BB23 | BB24 | BB25 | BB26 | BB27 | BB30 | |||||
. Insulated inverter systems | . . FORWARD types | . . . One element | . . . Two elements | . . . . Push-pull | . . . Half bridges or single-ended | . . . Full bridges | . . Modified FORWARD | |||||
BB32 | BB35 | BB37 | ||||||||||
. . Insulated BOOST types | . . . Centre tap types | . . . Full-bridge types | ||||||||||
BB42 | BB43 | BB44 | BB47 | BB48 | ||||||||
. . FLYBACK types | . . . One element | . . . Two elements | . . Insulated CUK types | . . SEPIC types | ||||||||
BB51 | BB52 | BB53 | BB54 | BB55 | BB57 | |||||||
. Non-resonance types | . . Self-excitation types | . . . by hysteresis | . . . by magnetic saturation of chokes | . . . by magnetic saturations of transformers | . . Separate excitation types e.g. those using oscillators | |||||||
BB61 | BB62 | BB63 | BB64 | BB65 | BB66 | BB67 | BB68 | BB70 | ||||
. Resonance types | . . Current resonance | . . . Full-wave resonance | . . . Half-wave resonance | . . . Partial resonance | . . . Series resonance | . . . Parallel resonance | . . . Series/parallel resonance | . . Multi resonance | ||||
BB72 | BB73 | BB74 | BB75 | BB76 | BB77 | BB78 | BB80 | |||||
. . Voltage resonance | . . . Full-wave resonance | . . . Half-wave resonance | . . . Partial resonance | . . . Series resonance | . . . Parallel resonance | . . . Series/parallel resonance | . . Insulated types including resonance elements also in the secondary sides | |||||
BB81 | BB82 | BB83 | BB84 | BB85 | BB86 | BB88 | BB89 | |||||
. with multiple conversion units | . . in parallel | . . . sharing conversion units partially | . . . Parallel operation of independent power sources | . . . outputs connected in series | . . in multi-stages | . . sharing control units and operation units | . . . by time division | |||||
BB91 | BB92 | BB94 | BB95 | BB96 | BB98 | |||||||
. making control other than switching inside conversion units | . . Bias of switching elements | . . Variable reactors | . . Third winding in main transformers | . . Series droppers excluding those of input circuits or output circuits | . . Switching of terminals or elements | |||||||
CC | CC00 INPUT UNIT |
CC01 | CC02 | CC03 | CC04 | CC05 | CC07 | CC10 | ||||
. rectifying ac currents | . . Three-phase ac | . . with special filters including active circuits | . . with means of improving power factors | . . . by switching control | . . obtaining synchronising signals from input ac | . Constant current sources | ||||||
CC11 | CC12 | CC13 | CC14 | CC16 | CC17 | |||||||
. with multiple input sources | . . selecting inputs by switching | . . . carrying out automatic switching | . . simultaneously input | . . with different voltages in input sources | . . with different types of input sources | |||||||
CC21 | CC22 | CC25 | CC26 | CC28 | ||||||||
. with means for stabilising voltages | . . by dropper control | . . by switching control | . . . synchronised with main conversion units | . . feedbacking output values of main conversion units | ||||||||
DD | DD00 SWITCHING UNIT IN MAIN CONVERSION UNIT |
DD01 | DD02 | DD03 | DD04 | DD05 | DD06 | DD07 | DD08 | DD09 | DD10 | |
. Kinds of switching elements | . . Transistors | . . . Insulated gate bipolar transistors (IGBT) | . . . Field effect transistors (FET) | . . Thyristors (SCR) | . . . Gate turn-off thyristors (GTO) | . . . Bidirectional triode thyristors | . . . Electrostatic induction thyristors | . . Electronic tubes | . . Mechanical contacts or relays | |||
DD11 | DD12 | DD13 | DD14 | DD15 | DD16 | DD17 | ||||||
. Connection modes of switching elements | . . Series connections | . . Parallel connections | . . Antiparallel connections | . . Darlington connections | . . Bridge connections | . . combining different elements | ||||||
DD21 | DD22 | DD23 | DD26 | DD27 | DD28 | |||||||
. driving switching elements | . . using drive transformers | . . . with third wiring in drive transformers | . . using drive transistors | . . . One element | . . . Two or more elements | |||||||
DD31 | DD32 | DD33 | DD34 | DD35 | ||||||||
. Drive waveforms | . . Rectangular waves | . . Trapezoidal waves | . . Triangular waves or sawtooth waves | . . Sinusoidal waves including partial sinusoidal waves | ||||||||
DD41 | DD42 | DD43 | ||||||||||
. with snubber circuits | . . Energy regeneration to input sides | . . Energy regeneration to output sides | ||||||||||
EE | EE00 OUTPUT UNIT |
EE01 | EE02 | EE03 | EE04 | EE05 | EE06 | EE07 | EE08 | EE10 | ||
. with rectifier circuits | . . Half-wave rectifier circuits | . . with centre taps | . . Bridge rectifier circuits | . . Hybrid bridge rectifier circuits | . . Voltage multiplier rectifier circuits | . . C output | . . L output | . . with flywheel diodes | ||||
EE12 | EE13 | EE14 | EE16 | EE17 | EE18 | EE19 | ||||||
. . Rectifier elements with control terminals | . . . output not being controlled e.g. synchronous rectification | . . . . Transistors | . . . with output control | . . . . Thyristors | . . . . Transistors | . . . . Field-effect transistors (FET) | ||||||
EE21 | EE22 | EE23 | EE24 | EE25 | EE27 | EE28 | EE30 | |||||
. for controlling or stabilising outputs excluding dummies | . . by using non-insulated choppers | . . . BUCK types | . . . BOOST types | . . . BUCK-BOOST types | . . . CUK types | . . . Non-insulated SEPIC types | . . . Resonance types | |||||
EE33 | EE34 | EE35 | EE36 | EE37 | EE38 | EE39 | ||||||
. . . Non-resonance types | . . . . Self-excitation types | . . . . by using hysteresis | . . . . by using magnetic saturation of chokes | . . . . Separate excitation types | . . . . . with independent oscillators | . . . . . synchronising with main conversion units | ||||||
EE42 | EE43 | EE44 | EE45 | EE46 | EE47 | EE48 | EE49 | |||||
. . by using means other than switching control | . . . Series droppers | . . . using variable reactors | . . . using saturable reactors | . . . . using magnetic amplifiers | . . . using ferroresonance circuits | . . . using piezo-electric transformers | . . . using special filters | |||||
EE51 | EE52 | EE53 | EE54 | EE56 | EE57 | EE58 | EE59 | EE60 | ||||
. with dummy loads | . . being controlled | . . . by dropper control | . . . by switching control | . Methods of controlling or stabilising outputs | . . by input voltage or current values of input units | . . by signals from main conversion units or main operation units | . . by feedback of output values | . . switching terminals or elements | ||||
EE61 | EE62 | EE63 | EE65 | EE66 | ||||||||
. with multiple outputs | . . with correlations between outputs | . . . adjusting balances of positive and negative outputs | . . by branching outputs halfway | . . . by using choke transformers | ||||||||
EE72 | EE73 | EE74 | EE75 | EE76 | EE77 | EE78 | EE79 | EE80 | ||||
. . with multiple windings in transformers | . . . Multi outputs | . . . . Positive and negative outputs | . . . Parallel connections | . . . Series connections | . . . with switching circuits | . . . having circuit types different in any kind | . . . . with ac outputs | . with input voltages or input currents | ||||
FD | FD00 SIGNAL DETECTION |
FD01 | FD02 | FD03 | FD07 | FD08 | FD09 | |||||
. of output voltages | . . Differentiated values | . . Integrated values or mean values | . . using non-resistive elements | . . . using choke coils or choke transformers | . . Detection of increases over threshold limit values by using Zener diodes | |||||||
FD11 | FD12 | FD13 | FD17 | FD18 | FD19 | |||||||
. of input voltages | . . Differentiated values | . . Integrated values or mean values | . . using non-resistive elements | . . . using choke coils or choke transformers | . . Detection of increments of threshold limit values by Zener diodes | |||||||
FD21 | FD22 | FD23 | FD24 | FD25 | FD26 | FD27 | FD28 | FD29 | FD30 | |||
. of other voltage | . . Differentiated values | . . Integrated values or mean values | . . from transformer windings | . . . of flyback voltages | . . of switching elements | . . using non-resistive elements | . . using choke coils or choke transformers | . . Detection of increments of threshold limit values by Zener diodes | . Special voltage divider circuits | |||
FD31 | FD32 | FD33 | FD37 | FD38 | ||||||||
. of output currents | . . Differentiated values | . . Integrated values or mean values | . . using non-resistive elements | . . using choke coils or choke transformers | ||||||||
FD41 | FD42 | FD43 | FD47 | FD48 | ||||||||
. of input currents | . . Differentiated values | . . Integrated values or mean values | . . using non-resistive elements | . . using choke coils or choke transformers | ||||||||
FD51 | FD52 | FD53 | FD57 | FD58 | ||||||||
. of other current | . . Differentiated values | . . Integrated values or mean values | . . using non-resistive elements | . . using choke coils or choke transformers | ||||||||
FD61 | FD62 | FD67 | FD68 | |||||||||
. other than voltages or currents | . . of frequency changes | . . using non-resistive elements | . . using choke coils or choke transformers | |||||||||
FF | FF00 COMPARISON UNIT, OPERATION UNIT OR SIGNAL TRANSMISSION UNIT |
FF01 | FF02 | FF03 | FF05 | FF06 | FF07 | FF08 | FF09 | FF10 | ||
. Analogue operations e.g. comparison operations | . . using triangle waves or sawtooth waves | . . Variable inclination of triangle waves | . . using hysteresis comparators | . making digital operations | . . using overflow pulses of counters | . . by comparing with contents of registers | . . using microcomputers or central processing units (CPU) | . using phase locked loop (PLL) circuits | ||||
FF11 | FF13 | FF15 | FF16 | FF17 | FF18 | FF19 | ||||||
. directly comparing multiple variables | . making non-linear signal processing | . characterised by transmitting signals | . . remotely | . . transmitting insulated signals | . . . using transmission transformers | . . . using photocouplers | ||||||
FG | FG00 CONTROL MODE |
FG01 | FG02 | FG03 | FG04 | FG05 | FG06 | FG07 | FG08 | FG09 | FG10 | |
. On/off control | . Pulse width control | . . On-width control with off-widths constant | . . Off-width control while making on-widths constant | . . Duty control or pulse width modulation (PWM) | . Pulse amplitude control i.e. pulse amplitude modulation (PAM) | . Frequency control i.e. pulse frequency modulation (PFM) | . Pulse number control | . Resonance frequency control | . Control by synthesising waveforms having different phases | |||
FG11 | FG12 | FG15 | FG16 | FG17 | FG18 | |||||||
. Sampling control | . Programme control | . Synchronous control | . . of multiple conversion units | . . of multiple power sources | . . with other apparatus e.g. televisions or computers | |||||||
FG21 | FG22 | FG23 | FG24 | FG25 | FG26 | FG30 | ||||||
. Control accompanied by mode changes | . . of control methods (FG01-FG12) | . . of conversion modes e.g. from dropper to switching | . . of applications e.g. from constant voltage to constant current and vice versa | . . of reference values or feedback values | . . by input voltage or input current | . without stabilisation control | ||||||
FV | FV00 MANUAL SETTING OR CHANGE |
FV01 | FV02 | FV03 | FV04 | FV05 | FV07 | FV08 | FV09 | |||
. Contents of changes | . . of control methods (FG01-FG12) | . . of conversion modes e.g. from droppers to switching | . . of applications e.g. from constant voltage to constant current and vice versa | . . of reference values or feedback values | . Setting means | . . by using voltage dividers or variable resistors | . . by using digital values | |||||
VV | VV00 AUXILIARY POWER SOURCE |
VV01 | VV02 | VV03 | VV06 | |||||||
. having another power source for control units | . . of non-insulated chopper systems | . . of insulated inverter systems | . having another power source for starting | |||||||||
XC | XC00 STARTING OR STOPPING |
XC01 | XC02 | XC03 | XC04 | XC05 | XC06 | XC07 | XC09 | |||
. Starting | . . of the entire power source | . . . Quick starts | . . . Soft starts | . . . . by using timers | . . . . making sequential starting | . . . . . relating to other apparatus | . . . . with means to prevent rush currents | |||||
XC12 | XC13 | XC14 | XC16 | XC17 | XC19 | XC20 | ||||||
. . of drive units or conversion units | . . . Quick starts | . . . Soft starts | . . . Pulse width control | . . . by the PFM control | . Manual stopping | . by remote control | ||||||
XX | XX00 PROTECTION OR PREVENTION |
XX01 | XX02 | XX03 | XX04 | XX05 | XX06 | XX09 | ||||
. Abnormal regions | . . Input or input units | . . Output or output units | . . Conversion units i.e. switching units | . . . Simultaneous conducting | . . . Commutation failure | . . Control units or feedback units | ||||||
XX11 | XX12 | XX13 | XX14 | XX15 | XX16 | XX18 | XX19 | |||||
. Contents of abnormalities | . . Overvoltages | . . Voltage drops | . . . Power failure or no outputs | . . Overcurrents | . . Overpower or overloads | . . Current unbalances or voltage unbalances | . . Heat generation | |||||
XX21 | XX22 | XX23 | XX24 | XX25 | XX26 | XX27 | XX28 | XX29 | XX30 | |||
. Abnormality detection regions | . . Inputs or input units | . . Outputs or output units | . . Conversion units | . . . Switching circuits | . . . . Switching elements | . . . Main transformers | . . . . Detection windings | . . Control units or feedback units | . . . Main control signals per se | |||
XX31 | XX32 | XX33 | XX35 | XX36 | XX37 | XX38 | XX40 | |||||
. Contents of detection | . . Overvoltage | . . Voltage drops | . . Current | . . Pulse duty | . . Frequencies | . . Temperatures | . . taking account of time or frequencies of abnormalities | |||||
XX41 | XX42 | XX43 | XX44 | XX45 | XX46 | XX47 | XX48 | XX49 | XX50 | |||
. Protection means | . . by stopping | . . . of switching elements directly | . . . of control circuits | . . . taking account of resetting or restarting | . . . by breaking elements | . . by droop control | . . . half recovery | . . . half recovery | . . warning or indicating | |||
ZZ | ZZ00 MECHANICAL STRUCTURE OR MATERIAL QUALITY |
ZZ01 | ZZ04 | ZZ05 | ZZ07 | ZZ09 | ||||||
. Housings or whole structure | . Wiring structures | . . Connectors or terminals | . Cooling structures | . Shield structures | ||||||||
ZZ11 | ZZ12 | ZZ13 | ZZ15 | ZZ16 | ZZ17 | ZZ18 | ZZ19 | |||||
. Arrangements of elements or parts | . Mounting structures of elements or parts | . . of switching elements | . Structures material qualities or materials of elements or parts per se | . . of main transformers | . . of reactors | . . . of saturable reactors | . . of piezo-electric transformers |