5G365 | Installation of bus-bars | |
H02G5/00 -5/10,391 |
H02G5/00;5/02;5/06,301;5/08,301;5/10,301 | AA | AA00 BUS-BAR STRUCTURE |
AA01 | AA02 | AA03 | AA05 | AA06 | |||||
. Plate-like bus-bars | . . Bus_bars with odd_shaped cross sections (e g L_shaped U_shaped or S_shaped cross_sections) | . . Insulated bus-bars | . Pipe-like bus-bars | . Other bus-bar structures | ||||||||
AB | AB00 BUS-BAR SUPPORT APPARATUSES |
AB01 | AB02 | AB03 | AB04 | AB05 | AB06 | |||||
. Plate-like or block-like apparatuses | . Apparatuses in the form of covers or cases | . Insulators | . Filled apparatuses | . Grooves for support of bus-bars | . Other bus-bar support apparatuses | |||||||
AC | AC00 BUS-BAR CONNECTIONS |
AC01 | AC02 | AC03 | AC04 | |||||||
. Fixed connections | . Detachable connections | . Connections that branch or intersect | . Other bus-bar connections | |||||||||
AD | AD00 OTHER BUS-BAR STRUCTURES |
AD01 | AD02 | AD03 | AD05 | AD06 | AD07 | |||||
. Prevention of bus-bar vibration | . Structures for insulation | . . Insulation barriers (e.g., interphase barriers) | . Cooling or heat radiation | . Installation in power-distribution panels | . Other bus-bar structures | |||||||
H02G5/04 | BA | BA00 PARTIALLY BLOCKED DUCTS |
BA01 | BA02 | BA03 | |||||||
. Ducts that use duct hangers | . Ducts that do not use duct hangers (i.e., direct attachment) | . Other partially blocked ducts | ||||||||||
H02G5/06,311@A-5/06,311@Z;5/08,311@J-5/08,311@Z;5/10,311 | CA | CA00 MEASURES TAKEN IN BUS DUCTS |
CA01 | CA02 | CA03 | CA04 | CA05 | CA06 | CA07 | |||
. Waterproofing, rain-proofing, or moisture-proofing | . Fireproofing, fire resistance, or heat resistance | . Prevention of induction heating | . Cooling or heat radiation | . Compensation for displacement or errors | . Measures for insulation (e.g., plates or sheets that insulate) | . Other measures provided for inside bus ducts | ||||||
CB | CB00 DUCT-CASE STRUCTURE |
CB01 | CB02 | CB03 | CB04 | |||||||
. Assembly with bolts | . Assembly with means other than bolts | . Cases that have holes | . Other duct-case structures | |||||||||
CC | CC00 BUS-DUCT CONNECTIONS |
CC01 | CC02 | CC04 | CC05 | CC06 | CC07 | CC09 | ||||
. Use of connecting bolts | . . Use of batch-tightened bolts | . Units that branch (e.g., welded unit) or end units | . . Plug-in units | . . . Connections inside bus ducts | . . . . Provision of contacts for plug-in fittings | . Other bus-duct connections | ||||||
CD | CD00 OTHER STRUCTURES IN BUS DUCTS |
CD01 | CD02 | CD03 | CD04 | CD06 | CD07 | |||||
. Variants that have conductors other than bus-bars | . Mounting of bus ducts | . . Duct hangers | . . Units that pass through walls or floors | . Indication or sensing | . Other structures in bus ducts | |||||||
H02G5/06,321-5/06,396;5/08,321-5/08,396;5/10,321-5/10,391 | DA | DA00 MEASURES TAKEN IN CONDUITS |
DA01 | DA02 | DA03 | DA04 | DA05 | DA06 | DA07 | DA09 | DA10 | |
. Prevention of the generation or intrusion of foreign material | . Waterproofing, moisture-proofing, or insect-proofing | . Airtightness or prevention of gas leakage | . Prevention of induction heating (e.g., magnetic shielding) | . Cooling or heat radiation | . . Forced cooling | . . . Variants that circulate coolant | . Measures for insulation | . . Prevention of discharge (e.g., shielding to moderate electrical fields) | ||||
DA12 | DA13 | DA14 | ||||||||||
. Grounding | . Short-circuiting | . Other measures taken in conduits | ||||||||||
DB | DB00 FORMS OF CONDUITS |
DB01 | DB02 | DB03 | DB04 | DB06 | ||||||
. Single-phase variants | . Polyphase variants (e.g., polyphase batch-type variants with separate phases) | . . Variants with separate phases | . . Polyphase batch-type variants | . Other forms of conduits | ||||||||
DC | DC00 STRUCTURE OF CENTER CONDUCTORS |
DC01 | DC02 | DC03 | DC04 | DC05 | ||||||
. Flexible variants (e.g., stranded wire or coils) | . Pipe-shaped variants | . Variants that have grooves or holes | . Surface structures (e.g., coatings) | . Other structures of center conductors | ||||||||
DD | DD00 SHEATH STRUCTURE |
DD01 | DD02 | DD03 | DD04 | DD05 | DD06 | |||||
. Variants that have magnetic shielding | . Variants that have lids or windows | . Variants that have grooves or holes | . Surface structures (e.g., coatings) | . Support apparatuses | . Other sheath structures | |||||||
DE | DE00 FORMS OF SPACERS |
DE01 | DE02 | DE03 | DE05 | DE06 | DE08 | DE09 | DE10 | |||
. Gas-shut-off types (e.g., combinations of disks and cones) | . . Disk types | . . Cone types | . Gas-flow types (e.g., loop types) | . . Post types (e.g., single leg or multiple legs) | . Ribbed types | . Sliding types | . Other forms of spacers | |||||
DF | DF00 STRUCTURE OF SPACERS |
DF01 | DF02 | DF03 | DF04 | DF05 | DF06 | |||||
. Support structures for center conductors | . Units for mounting on sheaths | . Variants that have metal flanges | . Variants that have grooves or holes | . Surface structures (e.g., coatings) | . Other structures of spacers | |||||||
DG | DG00 SPACER SHIELDING FOR REDUCING THE INTENSITY OF ELECTRIC FIELDS |
DG01 | DG02 | DG03 | DG04 | DG06 | ||||||
. Shielding on the center conductor | . Shielding on the sheath | . Shield rings | . . Rings embedded in spacers | . Other spacer shielding for reducing the intensity of electrical fields | ||||||||
DH | DH00 CONDUIT CONNECTIONS |
DH01 | DH02 | DH03 | DH04 | DH05 | DH07 | DH08 | DH09 | DH10 | ||
. Center-conductor connections | . . Fixed connections | . . Movable connections | . . Connection with clamped spacers | . . Shielding to reduce the intensity of electrical fields (e.g., covers or rings) | . Sheath connections | . . Connection by bolts | . . Connection by welding | . . Connection with flanges | ||||
DH11 | DH13 | DH15 | DH16 | DH17 | DH18 | |||||||
. . . Connection with clamped spacers | . . Connection without flanges | . Units that branch out | . End units or terminal units | . Connection to elements other than conduits (e.g., connections to electric equipment) | . Other conduit connections | |||||||
DJ | DJ00 TELESCOPING OR FLEXIBLE CONDUIT CONNECTIONS |
DJ01 | DJ02 | DJ03 | DJ04 | DJ06 | DJ07 | DJ08 | DJ10 | |||
. Types of displacement of conduits | . . Displacement along the conduit's length | . . Displacement in the direction of the conduits' diameter | . . Displacement at an angle from the direction in which the conduit runs | . Conduit-connecting structures | . . Center-conductor-connecting structures | . . Sheath-connecting structures | . Other telescoping or flexible conduit connections | |||||
DK | DK00 DETACHABLE CONDUIT CONNECTIONS |
DK01 | DK02 | DK03 | DK04 | |||||||
. Batch detachment of conduits | . Detachment of center conductors | . Detachment of sheaths | . Other detachable conduit connections | |||||||||
DL | DL00 TRAPPING AND REMOVAL OF FOREIGN PARTICLES |
DL01 | DL02 | DL03 | DL04 | DL05 | DL06 | DL07 | DL08 | |||
. Trapping at the spacer | . Trapping at the center conductor | . Trapping at the sheath | . Removal to the exterior of the conduit | . Use of trap electrodes | . Use of adhesive substances | . Protection from foreign particles | . Other trapping and removal of foreign particles | |||||
DM | DM00 INSULATING MEDIA |
DM01 | DM02 | DM04 | DM05 | DM06 | ||||||
. Feeding and discharge of insulating gas (e.g., filling with or recovery of gas) | . . Release of pressure | . Treatment of impurities (e.g., suction) | . Use of insulating oil | . Other insulating media | ||||||||
DN | DN00 SENSING AND TESTING |
DN01 | DN02 | DN03 | DN04 | DN05 | DN06 | |||||
. Sensing of current (e.g., current transformers) | . Sensing of voltage (e.g., transformers) | . Sensing of resistance | . Sensing of discharge | . Sensing of insulating gas | . Other sensing and testing | |||||||
DP | DP00 OTHER CONDUIT STRUCTURES |
DP01 | DP02 | DP04 | ||||||||
. Manufacture, assembly, or installation | . . Tools or apparatuses | . Other conduit structures |