H01B17/00-17/54@Z AA AA00
TYPES AND SHAPES OF INSULATORS
AA01 AA02 AA03 AA04 AA05 AA06 AA07 AA08
. Suspended insulators . Strain insulators . Long-rod insulators . Pin insulators . Line-post insulators . Support insulators . Insulating tubes . . Bushings
BA BA00
ELECTRICAL CONDITIONS REQUIRING INSULATION
BA01 BA02 BA03 BA04 BA05 BA06 BA07
. Flashover (i.e., breakdown of insulation) . . Flashover during specific malfunctions . . . Flashover during times of electrical abnormalities (e.g., lightning) . . . Flashover during mechanical abnormalities . Corona . . Noise . Electrical leaks or ground faults
BB BB00
MECHANICAL PURPOSES
BB01 BB02 BB03 BB04 BB05 BB06 BB07
. Mechanical strength in general . . Tension . . Compression . . Bending . . Torsion . . Impact . . Internal pressure
BB11 BB12 BB13 BB14 BB15 BB16 BB17
. Mechanical strength (i.e., during abnormalities) . . Tension . . Compression . . Bending . . Torsion . . Impact . . Internal pressure
BB21 BB22 BB24 BB25 BB26 BB27 BB28 BB29 BB30
. Protection from oscillation . Aerodynamic qualities . Change of shape (i.e., expansion) . Radiation of heat . Heat resistance . Arc resistance . Impulse resistance . Deterioration resistance . Resistance to chemical changes (e.g., electrolytic corrosion or rust)
BB31 BB32 BB33
. Ease of manufacturing . Use in factories or devices (i.e., installation and safety measures) . . Fastening or fixing
BC BC00
ENVIRONMENTAL CONDITIONS REQUIRING INSULATION
BC01 BC02 BC03 BC04 BC05 BC06 BC07 BC08 BC09
. Environment (weather) . . Temperature . . Humidity . . Water . . . Rain . . Wind . . Snow . . Lightning . . Dirt
BC11 BC12 BC13 BC14 BC15 BC16 BC17 BC18 BC19 BC20
. Humans . Animals . Plants . Generation of heat . Electrical discharges . . Flashovers and arcs . . Corona . Potential defects . Deterioration (BC20 takes precedence) . Chemical changes (e.g., electrolytic corrosion or rust)
CA CA00
CHARACTERISTIC MATERIAL OF THE MAIN ELEMENTS
CA01 CA02 CA03 CA04 CA05 CA06
. Ceramics . . Porcelain . . Glass . Resins . Rubber . Compound materials (e.g., fiber-reinforced plastics)
CB CB00
CHARACTERISTIC MATERIALS OF MEMBERS OTHER THAN THE MAIN ELEMENTS
CB01 CB02 CB03 CB04 CB05 CB06 CB07 CB08
. Cement . Resins . Oil . Gas . Specific organic substances . Specific inorganic substances . Specific conductors . Specific insulators
CC CC00
MATERIAL QUALITIES OF SURFACE ELEMENTS
CC01 CC02
. Surface treatments . . Glazing
DA DA00
APPLICATIONS TO SYSTEMS AND EQUIPMENT
DA01 DA02 DA03 DA04 DA05
. Application for electrical power systems . . Application for power-transmission systems . . Application for power-distribution systems . Application for equipment . Application to buildings other than those assigned in DA01 to DA04 (e.g., houses)
EA EA00
BASIC COMPONENTS OF INSULATOR DEVICES
EA01 EA02 EA03 EA04 EA05 EA06 EA07 EA08 EA09 EA10
. Steel towers and electric poles (i.e., including support arms) . Members between insulators and steel towers or between insulators and electric poles . . Fastening or fixing of insulators . . Moveable insulators . . . Insulators mounted axially along the lines . . . Insulators mounted orthogonally along the line . Insulators and insulator strings . . Multiple insulators or multiple insulator strings . . . Mutual arrangements . . . . Horizontal arrangements
EA11 EA12 EA13 EA14 EA15 EA16 EA17 EA18 EA19 EA20
. . . . Vertical arrangements . . . . Parallel arrangements . . . . V-shaped arrangements . . . . Inverted-V-shaped arrangements . Members that are between insulators . Members that are between the insulators and the lines . Lines . . Bare wires . . Insulated wires . . Jumper wires
EB EB00
ACCESSORY COMPONENTS FOR INSULATOR DEVICES
EB01 EB02 EB03 EB04 EB05 EB06 EB07 EB09 EB10
. Electrical discharge devices . . Arc horns . Devices for protection against lightning . . Use of gaps . . Use of protective elements or members . . . Lightning-protection elements that are built into the insulators . . . Lightning-protection elements that are attached to the exterior of the line . Devices for adjustment of the electrical field . . Rings
EB11 EB12 EB13 EB14 EB15 EB16 EB17 EB18 EB19 EB20
. Conductive devices . . Conduction by gaps . . Conduction by conductive bodies . Water-draining or water-diverting devices . . Umbrellas . Devices for monitoring, testing, and measuring . . Examination, monitoring, and measurement of insulators . . Sensors . . Devices using optical fibers . Maintenance devices (e.g., cleaning)
EB21
. Shock-absorbing devices
FA FA00
BASIC COMPONENTS OF INSULATING TUBES
FA01 FA02 FA03 FA04 FA06 FA08 FA09 FA10
. Bases and equipment shells . Members that are between the insulating tubes and the bases or between the insulating tubes and the equipment shells . Insulating tubes and bushings . . Multiple insulating tubes and multiple bushings . . Shapes . Members that are between the insulating tubes and the lines . Lines . Conductors that are inside insulating tubes
FB FB00
ACCESSORY COMPONENTS OF INSULATING TUBES
FB01 FB02 FB03 FB04 FB05 FB06 FB07 FB08 FB09 FB10
. Electrical discharge devices . . Arc horns . Devices for protection from lightning . . Use of gaps . . Use of lightning-protection elements or members . . . Lightning-protection elements that are inside the insulation tubes . . . Lightning protection elements that are attached to the exterior of the insulation tube . . Use of gaps . Devices for adjustment of the electrical field . . Shield-rings
FB11 FB12 FB13 FB14 FB15 FB16 FB17 FB18 FB19 FB20
. . Gaps . Conductive devices . . Conduction by gaps . . Conduction by conductive bodies . Water-draining or water-diverting devices . . Umbrellas . Devices for monitoring, examination, and measurement . . Examination, monitoring, and measurement of the insulating tubes . Maintenance devices (e.g., cleaning) . Shock-absorbing devices
TOP