ReturnTo Theme-Group-Choice | Onelevelup |
5G052 | SWITCH CASES, INDICATION, AND LOCKING | |
H01H9/00 -9/28;89/00-89/10 |
H01H9/00-9/28;89/00-89/10 | AA | AA00 PURPOSE |
AA01 | AA02 | AA03 | AA04 | AA05 | AA06 | AA07 | AA08 | AA09 | AA10 |
. Durability or reliability | . . Vibration resistance or shock resistance | . . Heat resistance or fire resistance | . . . Arc resistance | . . Waterproofing, drip-proofing, moisture-proofing | . . . Drainage | . . Dust-proofing | . . Pressure resistance | . . Explosion resistance | . . Insulating ability | |||
AA11 | AA12 | AA13 | AA14 | AA15 | AA16 | AA17 | AA18 | AA19 | ||||
. Switch assembly | . Switch mounting | . Replacement | . Combinations of multiple switches | . Incorporation of accessory parts | . . Fuses | . . Discharge means | . . Resistors | . . Indicating elements | ||||
AA21 | AA22 | AA23 | AA24 | AA25 | AA27 | AA28 | AA29 | AA30 | ||||
. Indication or warning | . . Indication of position where located | . . Indication of functions | . . Indication of whether on or off | . . Indication of abnormal operation | . Preventing malfunctions | . . Locking | . . . Vibration-proof locking | . . . Prevention of simultaneous closing | ||||
AA31 | AA32 | AA33 | AA34 | AA35 | AA36 | AA37 | AA40 | |||||
. Provision of greater capacity | . Standardization | . Adjustment | . Grounding | . Operability | . Testing or inspection | . . Tesing useful life | . Other purposes | |||||
BB | BB00 TYPES OF SWITCHES |
BB01 | BB02 | BB03 | BB04 | BB05 | BB06 | BB07 | BB08 | BB10 | ||
. Push-button switches | . Rotary switches | . Tumbler switches | . Slide switches | . Dual in-line package (DIP) switches | . Electromagnetic switches | . Circuit breakers or disconnectors | . Pull-out switches | . Other switches | ||||
H01H9/02-9/08;89/00-89/10 | HA | HA00 COMPONENT MEMBERS OF HOUSING MECHANISMS |
HA01 | HA02 | HA05 | HA06 | HA07 | HA08 | HA09 | |||
. Bases or cases | . . Terminal sections or wire lead sections | . Sealing members | . . Rings | . . Bellows | . . Diaphragms | . . Molded resin | ||||||
HA11 | HA12 | HA13 | HA14 | HA18 | ||||||||
. Protective covers | . . Covers for terminal sections | . . Covers for operating sections | . . Covers for the entire switch unit | . Flash plates | ||||||||
HA21 | HA22 | HA24 | HA30 | |||||||||
. Adapters for mounting | . . Variants that can be detached with a touch | . Instrument cases | . Other members | |||||||||
HB | HB00 ASSEMBLY AND MOUNTING MEANS FOR HOUSING MECHANISMS |
HB01 | HB02 | HB03 | HB04 | HB05 | HB06 | HB07 | HB08 | HB09 | HB10 | |
. Means for tightening screws | . . Nuts and bolts | . Means other than screws | . . Force fitting | . . . Elastic force fitting | . . Caulking | . . Welding or adhering | . . . Soldering | . . . Ultrasonic welding | . . Molding | |||
HC | HC00 LOCATIONS WHERE HOUSINGS ARE MOUNTED |
HC01 | HC03 | HC04 | HC06 | HC08 | HC10 | |||||
. Mounting on the fronts of equipment cases | . Mounting on mounting boards | . . Mounting on printed circuit boards | . Mounting on handles | . Mounting on wall | . Other places where mounted | |||||||
HD | HD00 MODES OF MOUNTING HOUSINGS |
HD01 | HD02 | HD03 | HD04 | HD10 | ||||||
. Mounting to be movable | . . Mounting to be able to retract and advance | . . . Turning | . . Rail-type movement | . Other modes of mounting | ||||||||
H01H9/16-9/18;89/00-89/10 | JA | JA00 POSITION OR ARRANGEMENT OF INDICATING MECHANISMS |
JA01 | JA02 | JA03 | JA06 | JA07 | JA08 | JA09 | |||
. Position of indication | . . Operating sections | . . Equipment cases | . Arrangement of indicating elements | . . Switch sections | . . . Operating sections | . . Equipment cases | ||||||
JB | JB00 TYPES OF INDICATING UNITS |
JB01 | JB02 | JB03 | JB04 | JB05 | JB06 | JB07 | JB08 | JB09 | JB10 | |
. Visual indication | . . Electrical variants | . . . Incandescent bulbs | . . . . Multi-lamp types | . . . LEDs (i.e., light-emitting diodes) | . . . . Segment or dot types | . . . LCD (liquid crystal display) | . . . Electroluminescence | . . . Cathode-ray tubes (CRT) | . . . Neon lamps | |||
JB11 | JB12 | JB13 | JB14 | JB15 | JB18 | JB19 | JB20 | |||||
. . Non-electrical variants | . . . Marks | . . . . Indicating sheets | . . . Indicating members that project | . . . Pointers | . Indication that is other than visual | . . Auditory variants | . . Tactile variants | |||||
JC | JC00 COMPONENT MEMBERS OF INDICATING MECHANISMS |
JC01 | JC02 | JC04 | JC05 | JC06 | JC07 | JC08 | JC09 | JC10 | ||
. Shutters | . . Rotary types | . Light-guide members | . . Prisms | . . Lenses | . . Optical fibers | . . Guide frames | . . Filters | . Reflecting plates | ||||
JC11 | JC12 | JC13 | JC14 | JC15 | JC16 | JC17 | JC18 | JC20 | ||||
. Means for moving indicating units | . . Rectilinear movement | . . Rotary movement | . Lamp holders | . . Elastic holding | . Power feed members | . . Contact springs | . . Coil springs | . Other compoment members | ||||
H01H9/20-9/28;89/00-89/10 | LA | LA00 TYPES OF LOCKING MECHANISMS |
LA01 | LA02 | LA03 | LA04 | LA07 | LA08 | ||||
. Mechanical locking | . . Locking of operating sections | . . Locking of power transmission sections | . . Locking of contact sections | . Electrical locking | . . Control of coil excitation | |||||||
LB | LB00 LOCKING MEANS |
LB01 | LB02 | LB03 | LB04 | LB05 | LB07 | LB10 | ||||
. Variants that use keys | . . Padlocks | . Variants that use rod members | . . Electromagnetic plungers | . Variants that use caps or covers | . Variants that use cams | . Other means | ||||||
LC | LC00 NUMBER OF SWITCHES IN LOCKING MECHANISMS |
LC01 | LC02 | LC03 | LC04 | |||||||
. One switch | . Two switches | . Three switches | . Four switches |