F-Term-List

5G027 Arc-extinguishing devices that are switches
H01H9/30 -9/52;33/00-33/26
H01H9/30;9/34-9/48;33/00-33/04;33/08-33/20;33/24 AA AA00
PURPOSE
AA01 AA02 AA03 AA04 AA06 AA08 AA09 AA10
. Switch performance . . Breaking performance . . . Arc-extinguishing . . . Suppressing restriking-voltage . . Power-on performance . . Insulation breakdown voltage . . . Electrical field buffering . . . Lightning surge countermeasures
AA11 AA13 AA14 AA15 AA17 AA18 AA19
. . . Waterproofing or moisture-proofing . . Durability . . . Heat resistance (i.e., including heat radiation and cooling) . . . Shock resistance or vibration resistance . Indication . . Indication of power on or off . . Indication of abnormalities
AA21 AA22 AA23 AA24 AA26 AA28 AA30
. Testing, inspection, or sensing . . Measurement of operations . . Measurement of the degree of contact wear . . Arc detection . Miniaturization, reduction of weight, or simplification . Working properties when assembling or mounting . Other purposes
H01H9/30;9/34;9/36;9/44-9/46;33/04;33/08;33/10;33/18-33/20 BA BA00
TYPES OF ARC-EXTINGUISHING
BA01 BA02 BA03 BA05 BA07 BA09 BA10
. Rotary arc types . . Movable contactors that are driven in a straight line . . . Use with gas blowing . Solenarc types . Attracting types . Forcing into narrow gaps . Other types
BB BB00
ARC DRIVING SOURCES
BB01 BB03 BB05 BB07 BB09 BB10
. Variants that use electromagnetic coils . Variants that use permanent magnets . Variants that use the action of the arc itself . Variants that use the action of a magnetic grid plate . Variants that use the action of current flowing through contactors and the like . Other driving sources
BC BC00
ARC-EXTINGUISHING DEVICE STRUCTURES
BC01 BC02 BC03 BC04 BC05 BC06 BC07 BC09
. Insulated arc-extinguishing gutters or tubes . . Insulated arc-extinguishing plates . Magnetic grid plates . . Sections where magnetic grid plates are fixed . Horn pieces . Iron cores or magnetic pole plates . Arcing horns or arc runners . Commutating plates
BC11 BC12 BC13 BC14 BC16 BC18 BC20
. Arc gas cooling or discharge means . Means for preventing arc gas jetting . Fluid spray means . Means for generating arc-extinguishing gas . Heat-shield plates . Means of attaching or supporting arc-extinguishing chambers . Other structures
H01H9/38-9/42;33/12-33/16 CA CA00
CONTACT SECTION STRUCTURES
CA01 CA02 CA03 CA05 CA06 CA07 CA08 CA09 CA10
. Main contact sections . . Types that are divided up . . With parallel capacitors . Auxiliary contact sections . . Resistor contact sections . . . Multistage switching . . . Resistor structure or installation . . Arc contact sections . Other contact section structures
H01H9/48;33/24 DA DA00
DISCHARGE PREVENTION DEVICES
DA01 DA02 DA04 DA06 DA08 DA10
. Shields . . Shields for contact sections . Capacitors or dielectrics . Insulators . Countermeasures for conductive impurities . Other discharge prevention devices
TOP