4C601 | Ultra sonic daignosis equipment | |
A61B8/00 -8/15 |
A61B8/00-8/15 | BB | BB00 SCANNING SYSTEMS |
BB01 | BB02 | BB03 | BB05 | BB06 | BB07 | BB08 | BB09 | BB10 | |
. Image pick-up spaces being one-dimensional | . Image pick-up spaces being two-dimensional | . Image pick-up spaces being three-dimensional | . Ultrasonic beam deflection systems | . . Electronic scanning | . . . Deflecting by variable delays | . . . Deflecting by selection of oscillators | . . Mechanical scanning (manual, or automatic) | . . . Acoustic mirror movement | ||||
BB11 | BB12 | BB13 | BB14 | BB15 | BB16 | BB17 | ||||||
. . . Oscillator movement | . . . Movement modes | . . . . Linear movement (linear) | . . . . Rotary movement (radial) | . . . . Oscillating movement (sector) | . . Combination of electronic type and mechanical type | . . Particularly manual scanning (freehand) | ||||||
BB21 | BB22 | BB23 | BB24 | BB25 | BB26 | BB27 | BB30 | |||||
. Linear | . Convex | . Sector | . Radial | . Arc | . Spiral | . Complex scanning | . Others | |||||
DD | DD00 MEASURING OBJECTS |
DD01 | DD02 | DD03 | DD04 | DD05 | DD06 | DD07 | DD08 | DD09 | DD10 | |
. Thickness, width, or length | . . Body fat layer thickness, or body fat amount | . Blood flow | . . Blood flow amount | . . Pulsation | . Blood pressure | . Pulses, or heart rates | . Mamma | . Fetus | . Bone | |||
DD11 | DD12 | DD13 | DD14 | DD15 | DD18 | DD19 | DD20 | |||||
. Head | . Teeth, or gums | . Eyes | . Blood vessel walls | . Heart | . Tissue parameters | . . Tissue elasticity (distortion distribution) | . . Speeds of sound | |||||
DD21 | DD22 | DD23 | DD26 | DD27 | DD30 | |||||||
. . Attenuation | . . Temperature | . . Excitation, or pressurization | . Bodily function measuring (measuring software) | . . Cardiac performance | . Others | |||||||
DE | DE00 SPECIAL TECHNOLOGY |
DE01 | DE02 | DE03 | DE04 | DE05 | DE06 | DE07 | DE08 | DE09 | DE10 | |
. Doppler | . . Continuous waves (CW) | . . Pulses (PW) | . . Color Doppler (CDI, CFM) | . . Power Doppler | . Photography using contrast preparations (including syringes). | . . Material | . Harmonic imaging | . . Tissue harmonic imaging | . . Contrast harmonic imaging | |||
DE11 | DE12 | DE13 | DE14 | DE15 | DE16 | DE17 | DE18 | DE20 | ||||
. . . TIC (time intensity curves) | . . Extraction of harmonic components | . . . Filters | . . . Phase inversion | . . . Sound pressure change | . Optoacoustics | . Transmission type | . . Performing CT reconstruction | . Others | ||||
EE | EE00 PURPOSE |
EE01 | EE02 | EE03 | EE04 | EE05 | EE06 | EE07 | EE08 | EE09 | EE10 | |
. Resolution improvement | . Noise reduction (electromagnetic) | . Sensibility improvement | . Image quality improvement (speckle, or clutter reduction) | . Expansion of the visual field | . Expansion of measuring ranges | . High-speed | . Frame rate improvement | . Accuracy improvement | . Reliability improvement | |||
EE11 | EE12 | EE13 | EE14 | EE15 | EE16 | EE17 | EE18 | EE19 | EE20 | |||
. Operability improvement | . Structure simplification | . Downsizing | . Cost reduction | . Power consumption reduction | . Safety improvement | . . Measures for pollution control | . . Insulation measures | . . Prevention of burns | . Patient pain alleviation | |||
EE21 | EE22 | EE23 | EE24 | EE30 | ||||||||
. Maintenance improvement | . Parameter optimization | . Environmental measures (e.g. recycling) | . Compliance with standards | . Others | ||||||||
FE | FE00 BODY CAVITY PROBES (OF BODY CAVITIES TO BE IMPARTED WITHOUT FAIL) |
FE01 | FE02 | FE03 | FE04 | FE05 | FE06 | FE07 | FE08 | FE09 | FE10 | |
. Ultrasonic endoscopes | . . Combination with optical endoscopes | . Body cavity catheters (forceps channels) | . Blood vessel catheters | . . Guide wires | . For oral cavity (dental use) | . Rectal, or vaginal insertion use | . Fixing means inside of the body | . Biplanes | . Multiplanes | |||
FF | FF00 SPECIAL APPLICATION |
FF01 | FF02 | FF03 | FF04 | FF05 | FF06 | FF08 | ||||
. Monitor for long time | . Probes during surgery | . Puncture | . . Removable puncturing instruments | . . Probe structures for puncture | . . Puncturing needles | . Biological signal synchronization | ||||||
FF11 | FF12 | FF13 | FF14 | FF15 | FF16 | FF20 | ||||||
. Combination with therapeutic instruments | . . Ultrasonic shock waves | . . Hyperthermia, or heating | . . Hot knives | . . Providing targets of energy irradiation | . . Observation of treated areas | . Others | ||||||
GA | GA00 CHARACTERIZED BY PROBES |
GA01 | GA02 | GA03 | GA04 | GA05 | GA06 | GA07 | GA08 | GA09 | ||
. Structures of cases | . . Drawing cables | . . Mounting oscillators and the like | . . Shielding, or grounding | . . . Shielding by conductive layers | . . Mounting markers, or indicators | . . Materials | . . Insulation | . Sterilizing, or disinfecting | ||||
GA11 | GA12 | GA13 | GA14 | GA15 | GA17 | GA18 | GA19 | GA20 | ||||
. Drive force transmission mechanisms | . . Directly driving with motors | . . Belts, or gears | . . Wires, or flexible joints | . . Magnetic means (except motors) | . Detection of probe information | . . Position detection of probes on body surfaces | . . Position detection of probes inside of the body | . . Position detection of inserted articles (e.g. catheter) inside of the body | ||||
GA21 | GA22 | GA23 | GA24 | GA25 | GA26 | GA27 | GA28 | GA29 | GA30 | |||
. . Position or angle detection | . . . Arm joints | . . . Potentiometers | . . . Acceleration sensors | . . . Magnetic sensors | . . . Echo uses | . . . . Using ultrasonic reflectors | . . . Mounting oscillators | . . . Detection of rotational positions of oscillators | . . . . Rotary encoders | |||
GA31 | GA32 | GA33 | GA40 | |||||||||
. . . . . Optical reflection, or transmission | . . . . . Optical electric resistances | . . Identification of probe information | . Others | |||||||||
GB | GB00 OSCILLATOR AND THE CIRCUMFERENCE STRUCTURES |
GB01 | GB02 | GB03 | GB04 | GB05 | GB06 | GB07 | GB08 | GB09 | GB10 | |
. Oscillators | . . Characterized by materials | . . Arrays | . . . One-dimensional arrays | . . . . Ring shapes | . . . Two-dimensional arrays | . . . . Beam controls in slicing directions | . . . . . Opening control only | . . . . Curved surfaces (including flexible) | . . . . . Cylinders | |||
GB11 | GB12 | GB13 | GB14 | GB15 | GB16 | GB17 | GB18 | GB19 | GB20 | |||
. . . . Sparse arrays | . . . Oscillation surface division drive type | . . . Ring or annular arrays | . . Other than arrays or oscillator elements in arrays | . . . Providing multiple layers of oscillators | . . . Making one oscillator by compound materials | . . . Curved surfaces | . Probe built-in circuits | . . Electrodes | . . Wiring and printed circuit boards | |||
GB21 | GB22 | GB24 | GB25 | GB26 | GB27 | GB28 | GB29 | GB30 | ||||
. . Element selection switches | . . Amplifiers | . Adjustment layers | . . Characteristics for materials | . . Between tested objects and oscillators | . . Between oscillators and dampers | . . Plural layers | . . Thickness of lambda/4 | . Back load materials (backing materials) | ||||
GB31 | GB32 | GB33 | GB34 | GB35 | GB36 | GB37 | GB38 | GB40 | ||||
. . Characteristics for materials | . Acoustic lenses | . . Characteristics for materials | . . Convex shape | . . Concave shape | . . Characteristics variable | . Acoustic mirrors | . . Concave shape | . Poling (polarization) | ||||
GB41 | GB42 | GB43 | GB44 | GB45 | GB46 | GB47 | GB48 | GB50 | ||||
. Characterized by preparation methods | . Materials | . . Metals | . . Ceramics | . . Polymers, or resins | . . Quartz, or glass | . . Mixed materials | . . Other materials | . Others | ||||
GC | GC00 ACOUSTIC COUPLING WITH TESTED OBJECTS |
GC01 | GC02 | GC03 | GC04 | GC05 | GC07 | GC09 | GC10 | |||
. Acoustic coupling media | . . Liquids (water, oils) | . . Gels (pads) | . . . Materials | . . Sols (pastes) | . Mounting structures between media and probes | . Media storage means | . . Liquid tanks, or chambers | |||||
GC11 | GC12 | GC13 | GC14 | GC15 | GC17 | |||||||
. . . Contact surfaces with tested objects (including acoustic windows) | . . Liquid bags (balloons) | . . . For body cavity | . . . For body surfaces | . . Having structures for diffuse reflection prevention | . Directly pressing oscillators with body cavity probes | |||||||
GC21 | GC22 | GC23 | GC24 | GC25 | GC26 | GC27 | GC28 | GC30 | ||||
. Operation to media | . . Supply or recovery of media | . . Sealing means | . . Removal of air bubbles | . . . Membranes | . . . Bubble traps | . . Temperature control | . . Pressure control | . Others | ||||
GD | GD00 SIGNAL TRANSMISSION (PROBES TO THE MAIN BODY) |
GD01 | GD02 | GD03 | GD04 | GD06 | GD09 | |||||
. Signal types | . . Other than electric signals | . . . Light | . . . Wireless | . Simultaneous use of power supplies | . Characteristics for noise control | |||||||
GD11 | GD12 | GD13 | GD14 | GD15 | GD18 | GD20 | ||||||
. Structures of transmission paths | . . Structures, or handling of cables | . . Transformer coupling | . . Relays | . . Slip rings | . . Connectors | . Others | ||||||
HH | HH00 TRANSMITTING AND RECEIVING CONTROL (BEAM FORMING) |
HH01 | HH02 | HH03 | HH04 | HH05 | HH06 | HH07 | HH08 | HH09 | HH10 | |
. Pulsers, drivers, or transmitting and receiving function switches | . Generation of transmitting waves | . . Continuous waves | . . Pulses | . . . Amplitude | . . . Frequencies | . . . Duty ratios | . . . Number of bursts | . . . Dispersion compression modes | . . . . Chirp pulses | |||
HH11 | HH12 | HH13 | HH14 | HH15 | HH16 | HH17 | ||||||
. . . . Other coded pulses | . . . Pulse generation timing | . . . . Periodic (PRF) control | . Scanning sequences | . . Scanning ranges | . . Scanning sequences (interlaced, alternate scanning) | . . Scanning line density | ||||||
HH21 | HH22 | HH23 | HH24 | HH25 | HH26 | HH27 | HH28 | HH29 | HH30 | |||
. Beam forming | . . Opening control | . . . Associated with deflection angles | . . . Associated with the depth | . . Apodization | . . Multi-beam formation | . . . Transmitting | . . . Receiving | . . Characteristic focusing | . . . Dynamic (multi-stage) focus | |||
HH31 | HH33 | HH35 | HH36 | HH38 | HH40 | |||||||
. . Characteristic beam deflection | . Correction of heterogeneity of speeds of sound | . Transmitting and receiving multiple frequencies (including broad bands) | . . Changing the transmitting frequencies according to the areas | . Opening synthesis | . Others | |||||||
JB | JB00 SIGNAL PROCESSING CIRCUITS |
JB01 | JB02 | JB03 | JB04 | JB05 | JB06 | JB07 | JB08 | JB09 | JB10 | |
. Delay circuits (including transmitting and receiving) | . . Analog beam formers | . . Digital beam formers | . . . Characterized by sampling (e.g. dithering) | . . . Characteristics for delay, or phase rotation | . . . Coupling with analog delay elements | . . Sharing among multiple of modes | . . Delay by dividing to multiple stages | . . Series and parallel connections of beam formers | . . Connections of multiple of signals (signal bundling) | |||
JB11 | JB12 | JB13 | JB14 | JB15 | JB16 | JB17 | JB18 | JB19 | JB20 | |||
. Signal amplification | . . AGC | . . TGC, or STC | . . . Amplification characteristic curves variable | . . Associated with deflection angles | . Gates | . . Automatically moving | . . Multiple gates | . Characterized by A/D conversion circuits | . . Effective uses of dynamic ranges | |||
JB21 | JB22 | JB23 | JB24 | JB25 | JB26 | JB28 | JB29 | JB30 | ||||
. Detection | . . Envelope detection | . . Phase detection | . . . Orthogonal detection | . . Reference frequencies variable | . . Multiple reference waves | . Filtering | . . Dynamic filters (associated with the depth) | . . MTI (Mobile object detection) | ||||
JB31 | JB32 | JB33 | JB34 | JB35 | JB36 | JB37 | JB38 | JB39 | JB40 | |||
. . LPF, BPF, or HPF | . . FIR, or IIR | . . Other filter characteristics variable | . Signal operation | . . Signal comparison | . . . Comparison of amplitude | . . . Comparison of phases | . . . Comparison of time | . . . Comparison of signals transmitted and received in different frequencies | . . . Comparison with reference signals | |||
JB41 | JB42 | JB43 | JB44 | JB45 | JB46 | JB47 | JB48 | JB49 | JB50 | |||
. . Taking correlations | . . . Echo uses | . . . . Doppler | . . . . Dispersion compression modes | . . Addition, subtraction, or synthesis (except phase regularization addition) | . . Differential, integration, or cumulative addition | . . Multiplication | . . Average | . . Fourier transformation | . . Peak value detection | |||
JB51 | JB52 | JB53 | JB54 | JB55 | JB56 | JB57 | JB60 | |||||
. . Correction of signals | . . . Correction of temperatures | . . . Optimization of parameters | . . . Correction of angles | . Scanning conversion in DSC | . . Addresses | . . Interpolation | . Others | |||||
JC | JC00 IMAGE PROCESSING |
JC01 | JC02 | JC03 | JC04 | JC05 | JC06 | JC07 | JC08 | JC09 | JC10 | |
. Interpolation | . . Spatial interpolation | . . Time base interpolation | . Averaging, or smoothing | . Lesion extraction | . Extraction of characteristic numbers | . . By concentration statistic values | . . By shape characteristics | . Contour extraction | . Edge enhancement | |||
JC11 | JC12 | JC13 | JC15 | JC16 | JC17 | JC18 | JC19 | JC20 | ||||
. Threshold processing | . Binarization, or ternarization | . Lesion diagnosis (degree of lesion) | . Processing between multiple images | . . Processing for time series images | . . . Weighting addition (Frame correlations) | . . . Time series differential images | . . Differentials (other than time series) | . . Image synthesis | ||||
JC21 | JC22 | JC23 | JC25 | JC26 | JC27 | JC28 | JC29 | JC30 | ||||
. . . Diagnosis images with each other | . . . . Coupling between adjacent images | . . Calculation of correlation coefficients | . Three-dimensional image processing | . . Rendering processing | . . . Surfaces | . . . . Shadows | . . . Solids | . . . . MIP, or MinIP | ||||
JC31 | JC32 | JC33 | JC37 | JC40 | ||||||||
. . . Online (real-time) processing | . . Coordinate transformation (Affine transformation) | . . Arbitrary excision of cross-sections | . Setting of regions of interest (ROI) | . Others | ||||||||
KK | KK00 DISPLAY, OR INPUT |
KK01 | KK02 | KK03 | KK04 | KK05 | KK06 | KK07 | KK08 | KK09 | KK10 | |
. Freeze | . Colors | . Correction of brightness (gray levels) | . . Windows, or means | . . Gamma correction | . . Variable according to each area or image | . Histograms | . Negative and positive, or mirror reversal images | . Rotation, or movement of images | . Enlargement, or reduction | |||
KK11 | KK12 | KK13 | KK14 | KK15 | KK16 | KK17 | KK18 | KK19 | KK20 | |||
. Display modes | . . B modes | . . M modes | . . A modes | . . C modes | . . Sound indication (e.g. Doppler sounds, alarms) | . . Spectra | . . Flow mapping | . . . Color conversion | . . . Performing vector indication | |||
KK21 | KK22 | KK23 | KK24 | KK25 | KK26 | KK27 | KK28 | KK29 | KK30 | |||
. Three dimensions | . . Corporal vision | . Display of multiple images | . . Superimposing | . . Parallel | . . . Splitting a screen into arbitrary number | . . Switchover | . Length, areas, or volumes | . . Displays of scales, or grids | . . Operation from designated areas | |||
KK31 | KK32 | KK33 | KK34 | KK35 | KK36 | KK37 | KK38 | KK39 | KK40 | |||
. Cursors, markers, characters | . . Body marks | . Diagnosis information | . . Probe relations | . . Personal information, date or the like | . . Biological signals | . Display speed control | . Characterized by display arrangements | . . Providing a plurality of display arrangements | . . CRT | |||
KK41 | KK42 | KK43 | KK44 | KK45 | KK46 | KK47 | KK48 | KK49 | KK50 | |||
. . Flat panels | . Input arrangements | . . Keyboards | . . Pointing devices (Track balls) | . . . Touch panels | . Diagnosis flow | . GUI | . . Customization | . Diagnosis reports | . Others | |||
LL | LL00 RECORDING, OR MAINTENANCE |
LL01 | LL02 | LL03 | LL04 | LL05 | LL06 | LL07 | LL09 | LL10 | ||
. Memories | . . Image memories | . . . Cine-memories (before scanning conversion) | . . . Multiple images memories (before scanning conversion) | . . Other applications | . . . Line memories | . . . Stacks, or buffers | . Image recording and reproducing | . . Analog recording (e.g. VTR) | ||||
LL11 | LL12 | LL13 | LL14 | LL15 | LL16 | LL17 | LL18 | LL19 | LL20 | |||
. . Digital recording (e.g. MO) | . . Original data recording | . Compression, or expansion for data | . Image database | . . Electronic charts | . . Consolidation of image formats | . Maintenance (Abnormality detection) | . . By communication | . . Phantoms | . Communication systems (Protocol) | |||
LL21 | LL23 | LL25 | LL26 | LL27 | LL28 | LL29 | LL30 | |||||
. Function extension by communication | . Telediagnosis | . Main body structures | . . Portable | . . Substitution of units | . . Measures against noise | . . . Having shields | . . Insulation | |||||
LL31 | LL32 | LL33 | LL35 | LL36 | LL38 | LL40 | ||||||
. . Characterized by housing structures | . . . Housing of probes | . Combination with other diagnosis arrangements (e.g. CT, MR) | . Peripheral environments | . . Beds | . Inventions of programs, or information recording media | . Having features not provided for other terms |