3L260 AIR CONDITIONING CONTROL DEVICE
F24F11/00 -11/89
F24F11/00;F24F11/30-11/89 AA AA00
PLACES WHERE AIR-CONDITIONING EQUIPMENT IS APPLIED
AA01 AA02 AA03 AA04 AA05 AA06 AA08 AA09
. In residential rooms . Bathrooms, toilets, sanitary . Kitchens . Offices, meeting rooms . Factories . . Clean rooms, clean booths . Stores (supermarkets, convenience stores) . Buildings with multiple tenants
AA11 AA12 AA13 AA14 AA15 AA16 AA20
. Computer rooms . Constant temperature and constant humidity tanks/equipment . Accommodation (hotels) . Outdoor facilities (including semi-open space such as stations or the like) . Greenhouses . Hospitals, clinics . Others
AB AB00
TYPE OF AIR CONDITIONERS
AB01 AB02 AB03 AB04 AB05 AB06 AB07 AB08 AB09
. Compression type refrigeration cycle (except for dehumidifiers) . . Separate type . . . Having multiple indoor machines . . . Having multiple outdoor machines/ compressors . . Integrated type, self-contained type . Cold and hot water type air conditioning . Central type air conditioning . Natural circulation cycle . Using natural energy/water vaporization heat
AB11 AB12 AB13 AB14 AB15 AB16 AB17 AB18 AB20
. Dehumidifiers . . Using adsorbents / desiccants . . Cool and condense objects . Humidifying objects . Ventilators . . Range hoods . . Heat exchange ventilators . Air cleaners . Others
BA BA00
PURPOSES, EFFECTS
BA01 BA02 BA03 BA04 BA05 BA06 BA07 BA08 BA09 BA10
. Improvement of amenity . . Improvement of temperature control performance . . . Improvement of heating performance . . . Improvement of cooling performance . . Dehumidification . . Humidification . . Adjustment of air volume/wind speed . . Adjustment of wind direction . . Air purification, dust collection of air, deodorization of air, odor removing from air . . Addition to air (scent, ion, oxygen or the like)
BA12 BA13 BA14 BA15 BA16 BA17 BA18 BA19 BA20
. . Ventilation . . . Introduction of outside air . . Simultaneous air conditioning for cooling and heating . . Low noise, muffling, vibration control . . Improvement of indoor hygiene (mold protection, sterilization) . . Stratified air conditioning, replacement air conditioning . . . Perimeter air conditioning . . Local / spot air conditioning . . Radiant air conditioning
BA22 BA23 BA24 BA25 BA26 BA27
. . Improvement of startup performance at the time of startup . . Response to situation changes (season, day and night) inside and outside rooms . . Countermeasures for dew condensation . . Health/physical condition management, consideration of individual differences . . . Suitable for sleeping . . Equalization of temperature, elimination of unevenness
BA31 BA32 BA33 BA34 BA35 BA36 BA37 BA38
. Maintenance of functions . . Protection of equipment/parts, improvement of durability, extension of life-span . . Prevention of erroneous operations/ erroneous inputs, child lock . . Improvement of hygiene inside air conditioners (mold protection, sterilization) . . Drain treatment . . Defrost, frost prevention / anti-freeze . . Test operations, demonstration operations . . Improvement/calibration of sensor accuracy and prevention of erroneous detection
BA41 BA42 BA43 BA44 BA45 BA46 BA47 BA48 BA49 BA50
. Energy saving / resource saving . . Power supply, demand control, power saving . . . Power distribution . . Schedule management . . Thermal storage, cold storage . . Effective use of natural energy . . Recycle oriented . . Utilization of multiple energy sources (electricity, gas or the like) . . Manufacturing cost, reduction of number of parts/number of equipment . . . Utilization of existing facilities
BA51 BA52 BA53 BA54 BA55 BA56 BA57
. Safety, countermeasures against abnormalities, redundancy . . Leakage of refrigerants / cold and hot water . . Blackout . . Failure of devices/parts . . . Failure of sensors . . Communication error . . Self-diagnosis
BA61 BA62 BA64 BA65 BA66
. Improvement of maintenance ability . . Maintenance of filters . Remote controls / monitoring systems, networks . . Address setting . . Improvement of communication performance
BA71 BA72 BA73 BA74 BA75 BA80
. Versatility among models, expansion / introduction / exchange of new models . Air treatment for food / goods or the like . Improvement of operability/view easiness of display unit . Cooperation with other apparatuses (illumination, hot water supply, and the like) . Simulation, numerical analysis, and design technique . Others
CA CA00
DETECTED/INPUTTED INFORMATION REGARDING THE ENVIRONMENT
CA01 CA02 CA03 CA04 CA05 CA06 CA07 CA08
. Information regarding the person . . Position of the person . . Presence or absence of person/number of persons . . Bio-information (skin/body temperature, or pulse), or activity quantity . . Attributes (social position, age, sex, or the like) of the person . . Sound of the person . . Movement / gesture or posture of the person . . Reporting demand, desire, questionnaire result, or feeling of cool or warm
CA11 CA12 CA13 CA14 CA15 CA16 CA17 CA18 CA19 CA20
. Indoor information . . Indoor temperature, cycling air temperature, or intake temperature . . Indoor humidity, indoor wet-bulb/dew point temperature . . Indoor atmospheric pressure . . Wind velocity, wind quantity, and wind blow direction . . Intake air temperature and blow out air temperature . . Indoor cleanliness degree/gas concentration . . Indoor sound/noise . . Open and close of window/door . . Illumination degree
CA22 CA23 CA24 CA25 CA26 CA27 CA28 CA29
. . Temperature of each building part . . . Floor temperature . . . Under floor temperature . . . Ceiling temperature (including ceiling space) . . . Wall face temperature . . . Perimeter/near window temperature . . Room shape/width . . Setting position of apparatus, information of obstacle/household articles
CA31 CA32 CA33 CA34 CA35 CA36 CA37 CA38 CA39 CA40
. Outdoor information . . Outside air temperature . . Outside humidity, outdoor wet-bulb/dew point temperature . . Sun light quantity/direction . . Outer air cleanliness degree/gas concentration . . Outdoor wind flow velocity/direction . . Outdoor atmospheric pressure . . Outdoor sound/noise . . Climate/weather information . . Underground/in ground temperature
CA50
. Others
CB CB00
COLLECTED/INPUT INFORMATION ON THE EQUIPMENT
CB01 CB02 CB03 CB04 CB05 CB06 CB07 CB08 CB09
. Information on compression refrigeration cycles . . Compressors . . . Temperature of compressors . . . Revolution rate of compressors, frequency of inverters . . Indoor (user side) heat exchangers . . . Temperature of indoor (user side) heat exchangers . . Outdoor (heat source side) heat exchangers . . . Temperature of outdoor (heat source side) heat exchangers . . Air temperature before or after the air passes through the heat exchanger
CB12 CB13 CB14 CB15 CB16 CB17 CB18 CB19 CB20
. . Refrigerant paths (four-way valve, etc.) . . Temperature of refrigerants and pipes (not the temperature of heat exchangers) . . . Discharge temperature . . . Excessive heating of refrigerants before they enter a compressor . . . Excessive cooling of refrigerants, temperature of refrigerants before they enter an expansion valve . . Refrigerant pressure . . . Pressure of refrigerants after exiting a compressor . . . Pressure of refrigerants before entering a compressor . . Refrigerant flow rate
CB22 CB23 CB24 CB25 CB26
. . Conditions of fans and devices that adjust air volume . . . Indoor (user side) fans . . . Outdoor (heat source side) fans . . Liquid storing devices (receiver, etc.) . . Expansion valves, orifices, ejectors
CB31 CB32 CB33 CB34 CB35 CB36 CB37 CB38 CB39 CB40
. Information on air conditioners that use hot and cold water . . Hot and cold water pumps . . Heat exchangers . . . Indoor (user side) hear exchangers . . Hot and cold water paths (valves, etc.) . . Temperature of supply water and pipes (excluding the temperature of heat exchangers) . . . Temperature of hot/cold water . . . Temperature of cooling water . . Pressure of supply water . . Flow rate of supply water
CB42 CB43 CB44 CB45 CB46
. . Heat source machines . . . Operational capacity of heat source machines and the number of them in operation . . Indoor (user side) fans . . Cooling towers . . Cooling water pumps
CB51 CB52 CB53 CB54 CB55 CB56 CB57
. Information on ventilation equipment/air flow paths in air conditioners . . Outside air intake fans . . Exhaust fans . . Circulation fans . . Air supply/exhaust paths (damper, etc.) . . Temperature of equipment/air flow paths . . Pressure of equipment/air flow paths
CB61 CB62 CB63 CB64 CB65 CB66 CB67 CB68 CB69 CB70
. Setting information, stored information . . Operation mode . . Related to temperature . . Related to humidity . . Related to air volume and speed . . Air flow direction settings . . Related to time . . . Operation time and duration . . . Time and date, day of the week, schedule . . Past history
CB71 CB72 CB74 CB75 CB77 CB78 CB79
. Dehumidifier . . Tanks, drain pans . Humidifiers . . Tanks . Power supplies . . Electric power . . Electric current/voltage
CB81 CB82 CB83 CB84 CB85 CB86 CB87 CB90
. Temperature of heat/cold storage units, heat storage capacity . Temperature of computers/servers . Condition of filters . Lighting equipment . Communication devices (speed and conditions of communication) . Information on devices in the system . Information on casing peripheral equipment (raising and lowering devices, etc.) . Others
DA DA00
TIMING OF SENSING/CONTROLLING
DA01 DA02 DA03 DA04 DA05 DA06 DA07 DA08 DA09 DA10
. Operational conditions of air conditioners . . Before air conditioning begins . . Immediately after air conditioning begins (at startup) . . Before air conditioning stops . . After air conditioning stops . . In standby state . . When air flow speed/direction changes . . When air conditioning load changes, when approaching target conditions . . When defrosting . . When abnormal events occur
DA11 DA12 DA13 DA15 DA20
. Preset time . . When power usage peaks . . At night, when electricity is inexpensive . During installation, maintenance . Others
EA EA00
CHARACTERISTICS OF CALCULATIONS/PROCESSING
EA01 EA02 EA03 EA04 EA06 EA07 EA08 EA09
. Prediction/estimation based on data . . Comfort index (PMV), feeling cool . . Inference of currently unknown values . . Prediction of future values . Comparison of data . . Comparison of input/computed values with reference values . . Comparison between simultaneously obtained input and computed values . . Comparison between different times
EA11 EA12 EA13 EA14 EA17 EA18 EA19
. Control mode . . On/off control . . Capability control . . . Duty ratio control . Reset data . Maintaining output for a certain duration/delaying output . Use of maps/tables
EA21 EA22 EA23 EA24 EA26 EA27 EA28 EA30
. Algorithm . . Control through learning . . Control of fluctuations . . PI/PID control . Correction of input values . Correction of reference/threshold values . Correction of formulas/models . Others
FA FA00
CONTROL DETAILS
FA01 FA02 FA03 FA04 FA05 FA06 FA07 FA08 FA09 FA10
. Change/resetting of set/target values . . Operation mode . . Target room temperature . . Target temperature of supply/emitted air . . Target temperature of heat exchangers . . Target humidity and dew-point temperature . . Air volume and speed settings . . Set air flow direction . . Power consumption and supply . . Temperature of cooling/cold/hot water
FA12 FA13 FA14 FA15 FA16 FA20
. . Related to time . . . Operation time . . . Start and end times of operation . . Priority of devices . . Number of devices in operation . Others
FB FB00
TARGETS TO BE CONTROLLED/TARGETS TO WHICH SIGNALS ARE SENT (TEMPERATURE AND HUMIDITY REGULATING DEVICES)
FB01 FB02 FB03 FB04 FB05 FB06 FB07 FB08 FB09 FB10
. Compression refrigeration cycles . . Compressors . . . Crankcase heaters . . . Inverter-equipped compressors . . . Engine driven compressors . . . Volume changeable compressors . . Expansion valves, orifices, ejectors . . Refrigerant control valves (excluding expansion valves) . . . Four-way valves . . . Hot gas bypass valves
FB12 FB13 FB14 FB15 FB16 FB17 FB18 FB19
. . Indoor (user side) fans . . Outdoor (heat source side) fans . . Defrost/anti-freezing devices . . Indoor (user side) hear exchangers . . Outdoor (heat source side) heat exchangers . . . Heat exchangers that exchange heat with liquids such as water . . Devices that supplementarily cool/heat refrigerants . . Branching units
FB21 FB22 FB23 FB24 FB25 FB26 FB27 FB28 FB29 FB30
. Air conditioners that use hot and cold water . . Supply water pumps . . . Hot and cold water pumps . . . Cooling water pumps . . Flow rate control valves . . . Bypassing of a heat exchanger between two headers . . . Valve installed for each indoor heat exchanger . . . Valve installed for each heat source machine . . Indoor heat exchangers, fan coil units . . Fans
FB32 FB33
. . Heat source machines . . Cooling towers
FB41 FB42 FB43 FB44 FB45 FB47 FB48
. Central air conditioners . . Condensers . . Heaters . . Fans . . Devices that draw in or condition outside air . Radiant air conditioning systems . . Radiant air conditioning systems that use hot and cold water
FB51 FB53 FB54 FB55 FB57 FB58 FB59 FB60
. Auxiliary means of heating/cooling . Special heat sources . . Use of natural energy (solar, geothermal) . . Waste and surplus heat . Heat/cold storage devices . . Ice thermal storage . . Heat storage using hot and cold water . . Heat storage using building frames
FB61 FB62 FB63 FB64 FB65 FB66 FB67 FB68 FB69 FB70
. Dehumidifiers/humidifiers . . Devices that use sorbents . . . Devices that use rotors . . . Batch devices . . . Reusable heat sources . . Devices that use water-absorbing liquids . . Humidifiers that do use the means of adsorption or absorption . . . Ultrasonic devices . . . Devices that heat humidifying parts (excluding reusable heat sources) . . . Amount of water entering humidifiers/amount of mist
FB72 FB73 FB80
. . Fans . . Water draining devices . Others
FC FC00
TARGETS TO BE CONTROLLED/TARGETS TO WHICH SIGNALS ARE SENT (AIR FLOW PATHS, PERIPHERAL EQUIPMENT)
FC01 FC02 FC03 FC04 FC05 FC06 FC07 FC08
. Means of ventilation, air flow paths . . Outside air intake fans . . Exhaust fans . . Circulation fans . . . Electric fans, air circulators . . Air supply/exhaust paths (damper, VAV) . . Indoor openings (in floors, ceilings, walls) . . Windows, doors
FC11 FC12 FC13 FC14 FC15 FC16 FC17
. Components attached to frames/casings . . Air intakes . . . Parts that open/close air intakes . . Air outlets . . . Vertical louvers . . . Horizontal louvers . . Raising and lowering devices
FC21 FC22 FC23 FC24 FC25 FC26 FC27 FC28
. Devices that treat air for the purposes other than adjusting its temperature or humidity . . Electrostatic dust collectors . . Filters . . . Filter cleaning devices . . Deodorizing devices . . Devices that add fragrance to the air . . Devices that add oxygen to the air . . Devices that produce ions or ozone/electrostatic atomizers
FC31 FC32 FC33 FC34 FC35 FC36 FC37 FC38 FC39 FC40
. Power supplies . Means of storing/backing up data . Communication devices (networking equipment, mobile phones) . Electricity/electronic circuits . Peripheral equipment . . Water heaters . . Blinds, curtains . . Lighting equipment . . Showcases . Others
GA GA00
RELATED TO OPERATION/DISPLAY
GA01 GA02 GA03 GA04 GA05 GA06
. Operation units . . Remote controls . . . Mounting . . . Button arrangements . . Touch panels . . Use of pull-down menus
GA11 GA12 GA13 GA14 GA15 GA16 GA17 GA18 GA19 GA20
. Output/display contents . . Temperature . . Humidity . . The amount of winds, wind velocity, wind direction . . Mode of operation and operational status . . Electric power, electric energy, electricity bill . . The abnormalities, alarm and advice . . Energy-saving effect . . Display/explanation of the control unit . . System and the attribute/information of a unit
GA22 GA23 GA24 GA26 GA27 GA28 GA30
. . History . . Time, period, schedule . . The quality of air, cleanliness factor and concentration . Constitution of the display . . Using seven segments . . Consisting of lamp strings . Others
HA HA00
DETAILS IN WHICH A CONTROL UNIT IS COMMON.
HA01 HA02 HA06 HA10
. A detecting element and a sensor . . Attachment . Timer . Others
JA JA00
A NETWORK AND A MEANS OF COMMUNICATION
JA01 JA02 JA03 JA04 JA05 JA06 JA07 JA08
. Signal transmission . . Signal transmission between the units outside the interior of a room . . . Multi-air-conditioner . . Signal transmission between different construction buildings . . The signal transmission of the main phone and a cordless handset . . . Main phone/representation machine being exterior units . . . Main phone/representation machine being interior units . . A program/transmission of machine type information
JA11 JA12 JA13 JA14 JA15 JA16 JA17 JA18 JA19 JA20
. Network . . Having a public network/LAN between the central apparatus and air-conditioning machines . . Public network/LAN between central apparatus and terminals . . Repeating installation between the central apparatus and the air-conditioning machines . . Connect with outside facilities through public network. . . Home network . . Network in an office/a building . . The terminal unit is a portable device. . . Containing peripheral equipment other than air-conditioning machine . . Having the feature in use of cable and radio
JA21 JA22 JA23 JA24 JA30
. The function of a central apparatus . . Only monitoring . . Performing a part of air-conditioning control with a central apparatus . . Performing all the air-conditioning control with a central apparatus . Others