3L260 | AIR CONDITIONING CONTROL DEVICE | |
F24F11/00 -11/89 |
F24F11/00;F24F11/30-11/89 | AA | AA00 PLACES WHERE AIR-CONDITIONING EQUIPMENT IS APPLIED |
AA01 | AA02 | AA03 | AA04 | AA05 | AA06 | AA08 | AA09 | ||
. In residential rooms | . Bathrooms, toilets, sanitary | . Kitchens | . Offices, meeting rooms | . Factories | . . Clean rooms, clean booths | . Stores (supermarkets, convenience stores) | . Buildings with multiple tenants | |||||
AA11 | AA12 | AA13 | AA14 | AA15 | AA16 | AA20 | ||||||
. Computer rooms | . Constant temperature and constant humidity tanks/equipment | . Accommodation (hotels) | . Outdoor facilities (including semi-open space such as stations or the like) | . Greenhouses | . Hospitals, clinics | . Others | ||||||
AB | AB00 TYPE OF AIR CONDITIONERS |
AB01 | AB02 | AB03 | AB04 | AB05 | AB06 | AB07 | AB08 | AB09 | ||
. Compression type refrigeration cycle (except for dehumidifiers) | . . Separate type | . . . Having multiple indoor machines | . . . Having multiple outdoor machines/ compressors | . . Integrated type, self-contained type | . Cold and hot water type air conditioning | . Central type air conditioning | . Natural circulation cycle | . Using natural energy/water vaporization heat | ||||
AB11 | AB12 | AB13 | AB14 | AB15 | AB16 | AB17 | AB18 | AB20 | ||||
. Dehumidifiers | . . Using adsorbents / desiccants | . . Cool and condense objects | . Humidifying objects | . Ventilators | . . Range hoods | . . Heat exchange ventilators | . Air cleaners | . Others | ||||
BA | BA00 PURPOSES, EFFECTS |
BA01 | BA02 | BA03 | BA04 | BA05 | BA06 | BA07 | BA08 | BA09 | BA10 | |
. Improvement of amenity | . . Improvement of temperature control performance | . . . Improvement of heating performance | . . . Improvement of cooling performance | . . Dehumidification | . . Humidification | . . Adjustment of air volume/wind speed | . . Adjustment of wind direction | . . Air purification, dust collection of air, deodorization of air, odor removing from air | . . Addition to air (scent, ion, oxygen or the like) | |||
BA12 | BA13 | BA14 | BA15 | BA16 | BA17 | BA18 | BA19 | BA20 | ||||
. . Ventilation | . . . Introduction of outside air | . . Simultaneous air conditioning for cooling and heating | . . Low noise, muffling, vibration control | . . Improvement of indoor hygiene (mold protection, sterilization) | . . Stratified air conditioning, replacement air conditioning | . . . Perimeter air conditioning | . . Local / spot air conditioning | . . Radiant air conditioning | ||||
BA22 | BA23 | BA24 | BA25 | BA26 | BA27 | |||||||
. . Improvement of startup performance at the time of startup | . . Response to situation changes (season, day and night) inside and outside rooms | . . Countermeasures for dew condensation | . . Health/physical condition management, consideration of individual differences | . . . Suitable for sleeping | . . Equalization of temperature, elimination of unevenness | |||||||
BA31 | BA32 | BA33 | BA34 | BA35 | BA36 | BA37 | BA38 | |||||
. Maintenance of functions | . . Protection of equipment/parts, improvement of durability, extension of life-span | . . Prevention of erroneous operations/ erroneous inputs, child lock | . . Improvement of hygiene inside air conditioners (mold protection, sterilization) | . . Drain treatment | . . Defrost, frost prevention / anti-freeze | . . Test operations, demonstration operations | . . Improvement/calibration of sensor accuracy and prevention of erroneous detection | |||||
BA41 | BA42 | BA43 | BA44 | BA45 | BA46 | BA47 | BA48 | BA49 | BA50 | |||
. Energy saving / resource saving | . . Power supply, demand control, power saving | . . . Power distribution | . . Schedule management | . . Thermal storage, cold storage | . . Effective use of natural energy | . . Recycle oriented | . . Utilization of multiple energy sources (electricity, gas or the like) | . . Manufacturing cost, reduction of number of parts/number of equipment | . . . Utilization of existing facilities | |||
BA51 | BA52 | BA53 | BA54 | BA55 | BA56 | BA57 | ||||||
. Safety, countermeasures against abnormalities, redundancy | . . Leakage of refrigerants / cold and hot water | . . Blackout | . . Failure of devices/parts | . . . Failure of sensors | . . Communication error | . . Self-diagnosis | ||||||
BA61 | BA62 | BA64 | BA65 | BA66 | ||||||||
. Improvement of maintenance ability | . . Maintenance of filters | . Remote controls / monitoring systems, networks | . . Address setting | . . Improvement of communication performance | ||||||||
BA71 | BA72 | BA73 | BA74 | BA75 | BA80 | |||||||
. Versatility among models, expansion / introduction / exchange of new models | . Air treatment for food / goods or the like | . Improvement of operability/view easiness of display unit | . Cooperation with other apparatuses (illumination, hot water supply, and the like) | . Simulation, numerical analysis, and design technique | . Others | |||||||
CA | CA00 DETECTED/INPUTTED INFORMATION REGARDING THE ENVIRONMENT |
CA01 | CA02 | CA03 | CA04 | CA05 | CA06 | CA07 | CA08 | |||
. Information regarding the person | . . Position of the person | . . Presence or absence of person/number of persons | . . Bio-information (skin/body temperature, or pulse), or activity quantity | . . Attributes (social position, age, sex, or the like) of the person | . . Sound of the person | . . Movement / gesture or posture of the person | . . Reporting demand, desire, questionnaire result, or feeling of cool or warm | |||||
CA11 | CA12 | CA13 | CA14 | CA15 | CA16 | CA17 | CA18 | CA19 | CA20 | |||
. Indoor information | . . Indoor temperature, cycling air temperature, or intake temperature | . . Indoor humidity, indoor wet-bulb/dew point temperature | . . Indoor atmospheric pressure | . . Wind velocity, wind quantity, and wind blow direction | . . Intake air temperature and blow out air temperature | . . Indoor cleanliness degree/gas concentration | . . Indoor sound/noise | . . Open and close of window/door | . . Illumination degree | |||
CA22 | CA23 | CA24 | CA25 | CA26 | CA27 | CA28 | CA29 | |||||
. . Temperature of each building part | . . . Floor temperature | . . . Under floor temperature | . . . Ceiling temperature (including ceiling space) | . . . Wall face temperature | . . . Perimeter/near window temperature | . . Room shape/width | . . Setting position of apparatus, information of obstacle/household articles | |||||
CA31 | CA32 | CA33 | CA34 | CA35 | CA36 | CA37 | CA38 | CA39 | CA40 | |||
. Outdoor information | . . Outside air temperature | . . Outside humidity, outdoor wet-bulb/dew point temperature | . . Sun light quantity/direction | . . Outer air cleanliness degree/gas concentration | . . Outdoor wind flow velocity/direction | . . Outdoor atmospheric pressure | . . Outdoor sound/noise | . . Climate/weather information | . . Underground/in ground temperature | |||
CA50 | ||||||||||||
. Others | ||||||||||||
CB | CB00 COLLECTED/INPUT INFORMATION ON THE EQUIPMENT |
CB01 | CB02 | CB03 | CB04 | CB05 | CB06 | CB07 | CB08 | CB09 | ||
. Information on compression refrigeration cycles | . . Compressors | . . . Temperature of compressors | . . . Revolution rate of compressors, frequency of inverters | . . Indoor (user side) heat exchangers | . . . Temperature of indoor (user side) heat exchangers | . . Outdoor (heat source side) heat exchangers | . . . Temperature of outdoor (heat source side) heat exchangers | . . Air temperature before or after the air passes through the heat exchanger | ||||
CB12 | CB13 | CB14 | CB15 | CB16 | CB17 | CB18 | CB19 | CB20 | ||||
. . Refrigerant paths (four-way valve, etc.) | . . Temperature of refrigerants and pipes (not the temperature of heat exchangers) | . . . Discharge temperature | . . . Excessive heating of refrigerants before they enter a compressor | . . . Excessive cooling of refrigerants, temperature of refrigerants before they enter an expansion valve | . . Refrigerant pressure | . . . Pressure of refrigerants after exiting a compressor | . . . Pressure of refrigerants before entering a compressor | . . Refrigerant flow rate | ||||
CB22 | CB23 | CB24 | CB25 | CB26 | ||||||||
. . Conditions of fans and devices that adjust air volume | . . . Indoor (user side) fans | . . . Outdoor (heat source side) fans | . . Liquid storing devices (receiver, etc.) | . . Expansion valves, orifices, ejectors | ||||||||
CB31 | CB32 | CB33 | CB34 | CB35 | CB36 | CB37 | CB38 | CB39 | CB40 | |||
. Information on air conditioners that use hot and cold water | . . Hot and cold water pumps | . . Heat exchangers | . . . Indoor (user side) hear exchangers | . . Hot and cold water paths (valves, etc.) | . . Temperature of supply water and pipes (excluding the temperature of heat exchangers) | . . . Temperature of hot/cold water | . . . Temperature of cooling water | . . Pressure of supply water | . . Flow rate of supply water | |||
CB42 | CB43 | CB44 | CB45 | CB46 | ||||||||
. . Heat source machines | . . . Operational capacity of heat source machines and the number of them in operation | . . Indoor (user side) fans | . . Cooling towers | . . Cooling water pumps | ||||||||
CB51 | CB52 | CB53 | CB54 | CB55 | CB56 | CB57 | ||||||
. Information on ventilation equipment/air flow paths in air conditioners | . . Outside air intake fans | . . Exhaust fans | . . Circulation fans | . . Air supply/exhaust paths (damper, etc.) | . . Temperature of equipment/air flow paths | . . Pressure of equipment/air flow paths | ||||||
CB61 | CB62 | CB63 | CB64 | CB65 | CB66 | CB67 | CB68 | CB69 | CB70 | |||
. Setting information, stored information | . . Operation mode | . . Related to temperature | . . Related to humidity | . . Related to air volume and speed | . . Air flow direction settings | . . Related to time | . . . Operation time and duration | . . . Time and date, day of the week, schedule | . . Past history | |||
CB71 | CB72 | CB74 | CB75 | CB77 | CB78 | CB79 | ||||||
. Dehumidifier | . . Tanks, drain pans | . Humidifiers | . . Tanks | . Power supplies | . . Electric power | . . Electric current/voltage | ||||||
CB81 | CB82 | CB83 | CB84 | CB85 | CB86 | CB87 | CB90 | |||||
. Temperature of heat/cold storage units, heat storage capacity | . Temperature of computers/servers | . Condition of filters | . Lighting equipment | . Communication devices (speed and conditions of communication) | . Information on devices in the system | . Information on casing peripheral equipment (raising and lowering devices, etc.) | . Others | |||||
DA | DA00 TIMING OF SENSING/CONTROLLING |
DA01 | DA02 | DA03 | DA04 | DA05 | DA06 | DA07 | DA08 | DA09 | DA10 | |
. Operational conditions of air conditioners | . . Before air conditioning begins | . . Immediately after air conditioning begins (at startup) | . . Before air conditioning stops | . . After air conditioning stops | . . In standby state | . . When air flow speed/direction changes | . . When air conditioning load changes, when approaching target conditions | . . When defrosting | . . When abnormal events occur | |||
DA11 | DA12 | DA13 | DA15 | DA20 | ||||||||
. Preset time | . . When power usage peaks | . . At night, when electricity is inexpensive | . During installation, maintenance | . Others | ||||||||
EA | EA00 CHARACTERISTICS OF CALCULATIONS/PROCESSING |
EA01 | EA02 | EA03 | EA04 | EA06 | EA07 | EA08 | EA09 | |||
. Prediction/estimation based on data | . . Comfort index (PMV), feeling cool | . . Inference of currently unknown values | . . Prediction of future values | . Comparison of data | . . Comparison of input/computed values with reference values | . . Comparison between simultaneously obtained input and computed values | . . Comparison between different times | |||||
EA11 | EA12 | EA13 | EA14 | EA17 | EA18 | EA19 | ||||||
. Control mode | . . On/off control | . . Capability control | . . . Duty ratio control | . Reset data | . Maintaining output for a certain duration/delaying output | . Use of maps/tables | ||||||
EA21 | EA22 | EA23 | EA24 | EA26 | EA27 | EA28 | EA30 | |||||
. Algorithm | . . Control through learning | . . Control of fluctuations | . . PI/PID control | . Correction of input values | . Correction of reference/threshold values | . Correction of formulas/models | . Others | |||||
FA | FA00 CONTROL DETAILS |
FA01 | FA02 | FA03 | FA04 | FA05 | FA06 | FA07 | FA08 | FA09 | FA10 | |
. Change/resetting of set/target values | . . Operation mode | . . Target room temperature | . . Target temperature of supply/emitted air | . . Target temperature of heat exchangers | . . Target humidity and dew-point temperature | . . Air volume and speed settings | . . Set air flow direction | . . Power consumption and supply | . . Temperature of cooling/cold/hot water | |||
FA12 | FA13 | FA14 | FA15 | FA16 | FA20 | |||||||
. . Related to time | . . . Operation time | . . . Start and end times of operation | . . Priority of devices | . . Number of devices in operation | . Others | |||||||
FB | FB00 TARGETS TO BE CONTROLLED/TARGETS TO WHICH SIGNALS ARE SENT (TEMPERATURE AND HUMIDITY REGULATING DEVICES) |
FB01 | FB02 | FB03 | FB04 | FB05 | FB06 | FB07 | FB08 | FB09 | FB10 | |
. Compression refrigeration cycles | . . Compressors | . . . Crankcase heaters | . . . Inverter-equipped compressors | . . . Engine driven compressors | . . . Volume changeable compressors | . . Expansion valves, orifices, ejectors | . . Refrigerant control valves (excluding expansion valves) | . . . Four-way valves | . . . Hot gas bypass valves | |||
FB12 | FB13 | FB14 | FB15 | FB16 | FB17 | FB18 | FB19 | |||||
. . Indoor (user side) fans | . . Outdoor (heat source side) fans | . . Defrost/anti-freezing devices | . . Indoor (user side) hear exchangers | . . Outdoor (heat source side) heat exchangers | . . . Heat exchangers that exchange heat with liquids such as water | . . Devices that supplementarily cool/heat refrigerants | . . Branching units | |||||
FB21 | FB22 | FB23 | FB24 | FB25 | FB26 | FB27 | FB28 | FB29 | FB30 | |||
. Air conditioners that use hot and cold water | . . Supply water pumps | . . . Hot and cold water pumps | . . . Cooling water pumps | . . Flow rate control valves | . . . Bypassing of a heat exchanger between two headers | . . . Valve installed for each indoor heat exchanger | . . . Valve installed for each heat source machine | . . Indoor heat exchangers, fan coil units | . . Fans | |||
FB32 | FB33 | |||||||||||
. . Heat source machines | . . Cooling towers | |||||||||||
FB41 | FB42 | FB43 | FB44 | FB45 | FB47 | FB48 | ||||||
. Central air conditioners | . . Condensers | . . Heaters | . . Fans | . . Devices that draw in or condition outside air | . Radiant air conditioning systems | . . Radiant air conditioning systems that use hot and cold water | ||||||
FB51 | FB53 | FB54 | FB55 | FB57 | FB58 | FB59 | FB60 | |||||
. Auxiliary means of heating/cooling | . Special heat sources | . . Use of natural energy (solar, geothermal) | . . Waste and surplus heat | . Heat/cold storage devices | . . Ice thermal storage | . . Heat storage using hot and cold water | . . Heat storage using building frames | |||||
FB61 | FB62 | FB63 | FB64 | FB65 | FB66 | FB67 | FB68 | FB69 | FB70 | |||
. Dehumidifiers/humidifiers | . . Devices that use sorbents | . . . Devices that use rotors | . . . Batch devices | . . . Reusable heat sources | . . Devices that use water-absorbing liquids | . . Humidifiers that do use the means of adsorption or absorption | . . . Ultrasonic devices | . . . Devices that heat humidifying parts (excluding reusable heat sources) | . . . Amount of water entering humidifiers/amount of mist | |||
FB72 | FB73 | FB80 | ||||||||||
. . Fans | . . Water draining devices | . Others | ||||||||||
FC | FC00 TARGETS TO BE CONTROLLED/TARGETS TO WHICH SIGNALS ARE SENT (AIR FLOW PATHS, PERIPHERAL EQUIPMENT) |
FC01 | FC02 | FC03 | FC04 | FC05 | FC06 | FC07 | FC08 | |||
. Means of ventilation, air flow paths | . . Outside air intake fans | . . Exhaust fans | . . Circulation fans | . . . Electric fans, air circulators | . . Air supply/exhaust paths (damper, VAV) | . . Indoor openings (in floors, ceilings, walls) | . . Windows, doors | |||||
FC11 | FC12 | FC13 | FC14 | FC15 | FC16 | FC17 | ||||||
. Components attached to frames/casings | . . Air intakes | . . . Parts that open/close air intakes | . . Air outlets | . . . Vertical louvers | . . . Horizontal louvers | . . Raising and lowering devices | ||||||
FC21 | FC22 | FC23 | FC24 | FC25 | FC26 | FC27 | FC28 | |||||
. Devices that treat air for the purposes other than adjusting its temperature or humidity | . . Electrostatic dust collectors | . . Filters | . . . Filter cleaning devices | . . Deodorizing devices | . . Devices that add fragrance to the air | . . Devices that add oxygen to the air | . . Devices that produce ions or ozone/electrostatic atomizers | |||||
FC31 | FC32 | FC33 | FC34 | FC35 | FC36 | FC37 | FC38 | FC39 | FC40 | |||
. Power supplies | . Means of storing/backing up data | . Communication devices (networking equipment, mobile phones) | . Electricity/electronic circuits | . Peripheral equipment | . . Water heaters | . . Blinds, curtains | . . Lighting equipment | . . Showcases | . Others | |||
GA | GA00 RELATED TO OPERATION/DISPLAY |
GA01 | GA02 | GA03 | GA04 | GA05 | GA06 | |||||
. Operation units | . . Remote controls | . . . Mounting | . . . Button arrangements | . . Touch panels | . . Use of pull-down menus | |||||||
GA11 | GA12 | GA13 | GA14 | GA15 | GA16 | GA17 | GA18 | GA19 | GA20 | |||
. Output/display contents | . . Temperature | . . Humidity | . . The amount of winds, wind velocity, wind direction | . . Mode of operation and operational status | . . Electric power, electric energy, electricity bill | . . The abnormalities, alarm and advice | . . Energy-saving effect | . . Display/explanation of the control unit | . . System and the attribute/information of a unit | |||
GA22 | GA23 | GA24 | GA26 | GA27 | GA28 | GA30 | ||||||
. . History | . . Time, period, schedule | . . The quality of air, cleanliness factor and concentration | . Constitution of the display | . . Using seven segments | . . Consisting of lamp strings | . Others | ||||||
HA | HA00 DETAILS IN WHICH A CONTROL UNIT IS COMMON. |
HA01 | HA02 | HA06 | HA10 | |||||||
. A detecting element and a sensor | . . Attachment | . Timer | . Others | |||||||||
JA | JA00 A NETWORK AND A MEANS OF COMMUNICATION |
JA01 | JA02 | JA03 | JA04 | JA05 | JA06 | JA07 | JA08 | |||
. Signal transmission | . . Signal transmission between the units outside the interior of a room | . . . Multi-air-conditioner | . . Signal transmission between different construction buildings | . . The signal transmission of the main phone and a cordless handset | . . . Main phone/representation machine being exterior units | . . . Main phone/representation machine being interior units | . . A program/transmission of machine type information | |||||
JA11 | JA12 | JA13 | JA14 | JA15 | JA16 | JA17 | JA18 | JA19 | JA20 | |||
. Network | . . Having a public network/LAN between the central apparatus and air-conditioning machines | . . Public network/LAN between central apparatus and terminals | . . Repeating installation between the central apparatus and the air-conditioning machines | . . Connect with outside facilities through public network. | . . Home network | . . Network in an office/a building | . . The terminal unit is a portable device. | . . Containing peripheral equipment other than air-conditioning machine | . . Having the feature in use of cable and radio | |||
JA21 | JA22 | JA23 | JA24 | JA30 | ||||||||
. The function of a central apparatus | . . Only monitoring | . . Performing a part of air-conditioning control with a central apparatus | . . Performing all the air-conditioning control with a central apparatus | . Others |