OVERALL CONFIGURATIONS
AA01 AA02 AA03 AA04
. Water supply types . . Storage types . . Continuous flow types . . Type that is the storage type and the continuous flow type at the same time
AA11 AA12 AA13 AA14
. Heat sources . . Multiple . . . Serial arrangement . . . Parallel arrangement
AA22 AA23 AA24 AA25 AA26 AA27 AA28 AA29
. . Main heat sources . . . Heat pumps . . . Solar heat (including waste heat from solar cells) . . . Geothermal heat . . . Waste heat . . . . CGS . . . . . Fuel cells . . . . . Engines
AA33 AA34
. . . Heaters . . . Combustion types
AA42 AA43 AA44 AA45 AA46 AA47 AA48 AA49 AA50
. . Auxiliary heat sources . . . Same as AA23-AA29 . . . Same as AA23-AA29 . . . Same as AA23-AA29 . . . Same as AA23-AA29 . . . . Same as AA23-AA29 . . . . . Same as AA23-AA29 . . . . . Same as AA23-AA29 . . . . Bathtubs
AA53 AA54
. . . Same as AA33-AA34 . . . Same as AA33-AA34
AA61 AA62 AA63 AA64 AA65 AA66
. Heat load . . Heating . . Filling the bathtub with hot water . . Bath reheating . . Shower/mist . . Load across multiple homes
AA71 AA72 AA73 AA74 AA75 AA76 AA77 AA78
. Auxiliary installations . . . Means of electricity storage . . Means of power generation . . Means of water treatment . . Means for washing piping or the like . . Means for preventing freezing . . . Using heaters . . . Using hot water
AB AB00
CONSTRUCTION OF HOT WATER STORAGE SECTIONS
AB01 AB02 AB03
. Multiple . . Serial arrangement . . Parallel arrangement
AB11 AB12
. Types of hot water tank . . Open type
AB21 AB22 AB23 AB24 AB25 AB26 AB27 AB29 AB30
. Types of heating . . Externally circulated heating type . . . Characterized by the channel from tank to tank through a heat source . . . . Switching channels . . . . Characterized by return position/exit position with respect to the tank . . . . . Multiple/variable return position/exit position with respect to the tank . . . . Bypassing the tank . . Externally directly heated type . . Internally heated type
AB32 AB33 AB34
. . Position of the auxiliary heat source . . . Hot water supply circuits . . . Heating circulating circuits
AB41 AB42 AB43 AB44 AB45 AB46 AB47
. Heat load heat exchanger inside the tank . Heat load heat exchanger outside the tank . . Characterized by the channel from tank to tank through a heat load heat exchanger . . . Switching channels . . . Characterized by return position/exit position with respect to the tank . . . . Characterized by return position/exit position with respect to the tank . . . With bypasses
AB51 AB52 AB53 AB54 AB56 AB57 AB58 AB59 AB60
. Characterized by a hot water exit position with respect to the hot water supply channel . . Switching channels . . Characterized by the exit position from the tank . . . Multiple/variable exit positions from the tank . Details . . Structures of water supply units . . Structures of water intake units . . Means for separating hot from cold water . . Means for retaining heat/preventing heat release
AB62 AB63 AB64 AB65 AB66 AB67 AB68
. . Venting means . . Safety valves . . Draining means . . Stirring means . . Partitioned tank interior . . Means for preventing corrosion . . Heat storage elements in the tank
AC AC00
CONSTRUCTION OF HEAT PUMPS
AC01
. Heat pumps provided in multiple steps
AC11 AC12 AC13 AC14 AC15 AC16 AC17 AC18
. Heat sources for heat pumps (heat sources other than air) . . Solar heat (including waste heat from solar cells) . . Geothermal heat . . Waste heat . . . CGS . . . . Fuel cells . . . . Engines . . . Bathtubs
AC21 AC22 AC23 AC24 AC25 AC26 AC27 AC28
. Characteristics of heat pump cycles . . With bypass channels . . With ejectors . . With auxiliary means for cooling/heating refrigerant . . . Heat exchange between refrigerants . . . Heat exchange with hot or cold water at other than condensers . . Air conditioning using refrigerant . . Multiple condensers
AC32 AC33 AC34 AC35 AC36 AC37
. . Defrosting . . . Reverse cycle . . . Hot-gas bypass . . . Increasing the opening of expansion means . . . With heating means for defrosting . . . . Using stored hot water as a heat source
AC41 AC42 AC43 AC44
. Details . . Heat insulating structures . . Noise control structures . . Arrangement inside casings
AD AD00
CONSTRUCTION OF CGS
AD01 AD04 AD05 AD06
. Connections with commercial power supplies . Incidental equipment . . Means for consuming excess electric power (e.g. heaters) . . Means for releasing heat (e.g. radiators)
BA BA00
DETECTION INFORMATION (OVERALL, ENVIRONMENTAL)
BA01 BA02 BA03 BA04
. Water supply system information . . Temperature of supplied water . . Water supply pressure . . Flow rate of water supply
BA11 BA12 BA13 BA14 BA15 BA17 BA18
. Hot water supply system information . . Hot water temperature at the entrance of mixing means . . Hot water temperature at the exit of mixing means . . Flow rate of hot water supply . . Mixing means (mixing valve opening or the like) . Heat sources . . Output of heat sources
BA21 BA22 BA23 BA24 BA25 BA26 BA27
. Systems for filling baths/reheating or heating systems . . Temperature of hot water at the entrance of mixing means . . Temperature of hot water at the exit of mixing means . . Flow rate for filling baths/level of bathwater . . Mixing means (mixing valve opening or the like) . . Bathtub hot water temperature/heat radiator temperature . . Flow rate for circulating hot bathtub water/circulating pump output
BA31 BA32 BA33 BA34 BA35 BA36 BA37 BA38
. Environmental information . . Fresh air temperature . . Indoor air temperature . . Weather/Sunshine . History information . . Operation history . . History of consuming hot water/electric power or the like . . Failure information
BA41 BA42 BA43 BA44 BA45
. Failure/error information . Other information . . Stay information/bathing detection information . . Time/period (e.g. day of the week, month, season) . . Installation location information/user position information
BB BB00
DETECTION INFORMATION (HOT WATER STORAGE SECTIONS)
BB01 BB02 BB03 BB04 BB05 BB06
. Hot water tanks . . Temperature . . . Temperature distribution/amount of hot water . . . Temperature of hot water in the vicinity of internal heat exchangers for heat load . . . Amount of heat stored . . Water level (water surface level)
BB11 BB12 BB13 BB14 BB15 BB16
. External circulating heating channels . . Temperature at the exit of the hot water tank . . Temperature at the entrance of a heat source (heat exchanger) . . Temperature at the exit of a heat source (heat exchanger) (boiling temperature) . . Temperature at the entrance of the hot water tank . . Circulation flow rate/circulation pump output
BB21 BB22 BB23 BB24 BB25 BB26 BB27 BB28 BB29
. Heat load (heat exchanger) systems . . Temperature of fluid to be heated (e.g. bathtub water) at the entrance of the heat exchanger . . Temperature of fluid to be heated (e.g. bathtub water) at the exit of the heat exchanger . . Flow rate of fluid to be heated (e.g. bathtub water) . . Temperature of heating fluid (stored hot water) at the exit of a hot water tank . . Temperature of heating fluid (stored hot water) at the entrance of the heat exchanger . . Temperature of heating fluid (stored hot water) at the exit of a heat exchanger . . Temperature of heating fluid (stored hot water) returning to the hot water tank . . Circulating flow rate of heating fluid (stored hot water)/circulating pump output
BB31 BB33 BB34 BB35 BB36 BB37
. Temperature of hot water at the exit of the tank on the high temperature side . Medium temperature water supply . . Temperature of hot water supply at the entrance of mixing means . Temperature of hot water supply at the exit of mixing means . . Flow rate . . Mixing means (mixing valve opening or the like)
BC BC00
DETECTION INFORMATION (HEAT PUMPS)
BC01 BC02 BC03 BC04 BC05
. Compressors . . Rotation speed . . Compressor temperature . Expansion means (opening) . Frost detection
BC11 BC12 BC13 BC14 BC15 BC16 BC17 BC18 BC19 BC20
. Refrigerant/refrigerant lines . . Compressor exit temperature/condenser entrance temperature . . Water-refrigerant heat exchanger (condenser) temperature . . Expansion means entrance temperature/condenser exit temperature . . Air-refrigerant heat exchanger (evaporator) entrance temperature . . Temperature at the entrance of a heat exchanger (evaporator) between heat source other than air and refrigerant . . Compressor entrance temperature/evaporator exit temperature . . Compressor exit pressure/condenser entrance pressure . . Condenser exit pressure/expansion means entrance pressure . . Expansion means exit pressure/evaporator entrance pressure
BC22 BC23
. . Compressor entrance pressure/evaporator exit pressure . . Refrigerant flow rate
BC31 BC32 BC33 BC34 BC35 BC36 BC37 BC38 BC39 BC40
. Air side of the air heat exchanger . . Entrance temperature . . Exit temperature . . Heat-exchanger surface temperature . . Amount of air fed/fan output . Heat source fluids other than air (e.g. bathtub water) . . Entrance temperature . . Exit temperature . . Heat-exchanger surface temperature . . Heat source fluid flow rate/output of the pump or the like
BD BD00
DETECTION INFORMATION (CGS)
BD01 BD02 BD03 BD04 BD05
. Cooling water . . Temperature at the entrance of a waste-heat heat exchanger . . Temperature at the exit of a waste-heat heat exchanger . . Temperature of at the entrance of a waste-heat heat exchanger . . Temperature at the exit of the waste heat source
BD11 BD12 BD13 BD14 BD15
. Electric power . . Power generated . . Power consumed . . Power purchased . . Power sold
CA CA00
DETECTION/CONTROL PERIOD
CA01 CA02 CA03 CA04 CA05 CA06
. During start . During stop . During load fluctuation . Under overload . During error/failure . During installation/test runs/maintenance
CA11 CA12 CA13 CA14 CA15 CA16
. During stop/standby . . During extended periods of not being used due to the absence of the user or the like . Specific time of the day/season . . Night time zone . . During power peaks . Upon user commands
DA DA00
OBJECTS TO BE CONTROLLED
DA01 DA02
. Heat sources . . Auxiliary heat sources
DA11 DA12 DA13 DA14 DA15 DA16
. Hot/cold water supply sections . . Means for controlling the amount of hot water supply . . Hot/cold water mixing means . . Means for shutting off water supply . . Means for switching channels . Incidental equipment
DA21 DA22 DA23 DA24 DA25 DA26
. Heat pumps . . Compressors . . Expansion means . . Fans . . Means for switching refrigerant channels . . Means for assisting in cooling/heating refrigerant
DA31 DA32 DA33 DA34 DA35 DA36
. Hot water storage sections . . Means for switching channels from tank to tank through heat source . . Means for regulating flow rate from tank to tank through heat source (circulating pumps or the like) . . Means for switching channels from tank to tank through external load/for supplying hot water . . Means for regulating flow rate from tank to tank through external load (circulating pump or the like) . . Means for mixing medium temperature water
EA EA00
CONTENT OF CONTROL
EA01 EA02 EA03 EA04 EA05 EA06 EA07 EA08 EA09
. Control of the temperature of hot water supplied . . Stabilizing the temperature of hot water supply . Control of the amount of hot water supplied . . Control of the amount distributed to multiple locations . Control of the amount of heat . . Control of the number of heat sources . . Distributing the amount of heating to multiple heat sources . Control of connections between hot water supply units . Switching operational modes
EA11
. Control based on the quality of water supplied
EA21 EA22 EA23 EA24
. Safety control . . Preventing freezing . . Preventing discharge at high temperature . . Dealing with power outages
EA32 EA33 EA34 EA35 EA36
. . Preventing leaks/dropping . . Preventing short circuits . . Dealing with water failure . . Failure handling/diagnosis . . Venting lines
EA41 EA42 EA43 EA44 EA45 EA46 EA47 EA48 EA49 EA50
. Hot water storage type . . Setting heating schedules . . Control based on forms of power contracts . . . Control based on power discount time zone such as midnight electricity . . . Demand control . . . Preventing hot water from running out/control for additional reheating (heating during the daytime when power rate is high) . . Control of temperature inside the tank . . . Temperature distribution . . . Equalizing temperatures within the tank . . Control of the amount of stored hot water/stored heat
EA52 EA53 EA54 EA55 EA56 EA57
. . Heating temperature . . Preventing excess pressure . . Preventing heating of an empty tank . . Venting cans . . Maintaining/cleaning water quality inside the tank . . Drain control
EA61 EA62 EA63 EA64 EA65 EA66 EA67 EA68
. Heat-pump type . . Compressor protection . . Defrosting control . . Increasing the efficiency of heat pumps . . . Maintaining temperature stratification . . . Positively using medium temperature water . . . Cooling water supplied to heat pumps . . Preventing noise
EA71 EA72 EA73 EA74 EA75 EA76 EA77 EA78 EA79
. CGS . . Creating operation schedules . . Controlling cooling water temperature . . Numbers of times of operation and stop . . Operating hours . . Dealing with extra heat . . . Dealing with extra power . . . Power-first, heat-second operation . . Heat-first, power-second operation
FA FA00
OPERATION/REPORTING
FA01 FA02 FA03 FA04 FA05 FA06 FA07 FA08 FA09
. Operating units . . Remote controllers . . . Characterized by operating units/display units of remote controllers . . Mobile terminals/PC or the like (operated via the Internet) . . Surveillance centers . Content of operation . . Remotely starting or stopping equipment . . Setting amount of hot water or heat stored in the hot water tank . . Setting operation schedules
FA11 FA12 FA13
. Modes of reporting . . Sound . . Display
FA21 FA22 FA23 FA24 FA25 FA26 FA27 FA28
. Content of report/content of information . . Operation guidance/navigation guidance . . Information on running costs/amount of hot water sued . . Operating states . . . Amount of hot water/heat stored in the hot water tank . . . Operational modes . . Setting information . . Errors or dangers
FA32 FA33 FA34 FA35
. . Operating history . . Operation schedule . . Urging users to do maintenance or the like . . Failure history/failure information/failure diagnosis
GA GA00
PURPOSES/OTHERS
GA01 GA02 GA03 GA04 GA05 GA06 GA07 GA08 GA09 GA10
. Simplification or standardization of construction/control/operation . Manufacturing methods . Field construction/field assembly/methods of test runs . Methods of maintenance/dismantling . Reduction of the cost of miniaturization/facilities . Durability or reliability . Disaster readiness . Improvement of detecting accuracy . Improvement of safety . Measures against water failure
GA11 GA12
. Measures against water leaks . Reduction of standby power