ReturnTo Theme-Group-Choice | Onelevelup |
(Not Translated)
3K068 | FEEDING AND CONTROLLING FUEL | |
F23K5/00 -5/22;F23N1/00-1/00,117@Z;5/26-5/26,101@Z |
F23K5/00-5/22 | AA | AA00 FUEL TYPE |
AA01 | AA02 | AA03 | AA04 | AA05 | |||||
. Gaseous fuels | . . Liquefied gases | . . Methane gas | . . Acetylene gas | . . Hydrogen | ||||||||
AA11 | AA12 | AA13 | AA14 | AA15 | AA16 | AA18 | AA19 | |||||
. Liquid fuels | . . Heavy oils e.g. pitch or tar | . . . Heavy oils | . . Light oils | . . . Kerosene | . . . Gasoline | . . Alcohol | . . Waste oils or waste liquids | |||||
AB | AB00 FUEL PREPARATION |
AB01 | AB02 | AB03 | AB04 | AB05 | AB06 | AB07 | AB08 | AB10 | ||
. Mixing | . . Mixing of multiple fuels | . . Mixing of liquids e.g. emulsion fuels | . . Mixing of gases | . . Addition of modifiers | . . . Pollution-control agents | . . . Corrosion inhibitors | . . . Slagging-preventing agents | . . using ultrasonic waves | ||||
AB11 | AB12 | AB13 | AB14 | AB15 | AB16 | AB19 | AB20 | |||||
. Separation | . . Separation of liquids | . . . by absorbents | . . Separation of gases | . . Separation of solids | . . . Screens or filters | . Heating | . . Electric heaters | |||||
AB21 | AB22 | AB23 | AB24 | AB27 | AB28 | AB29 | ||||||
. . Combustion heat | . . Steam | . . Vaporisation | . . . using reboilers | . Cooling | . . Air cooling | . . Liquefaction or solidification | ||||||
AB31 | AB32 | AB35 | AB36 | AB37 | AB38 | |||||||
. Cutting or crushing | . . Atomisation | . Other modifications | . . using catalysts | . . by electricity or magnetism | . . . using permanent magnets | |||||||
BA | BA00 SUPPLY FORM |
BA01 | BA02 | BA03 | BA06 | BA07 | BA08 | BA09 | ||||
. Supply to multiple burners | . . to pilot burners | . Supply of multiple fuels | . Supply under special loads | . . during start-up periods | . . . for ignition | . . for extinguishing fire | ||||||
BB | BB00 REGULATION OF SUPPLY |
BB01 | BB02 | BB03 | BB04 | BB05 | ||||||
. Flow regulation | . Pressure regulation | . Temperature regulation | . Compensation | . Distributing or switching | ||||||||
BB11 | BB12 | BB13 | BB14 | BB15 | BB16 | BB17 | BB18 | BB19 | BB20 | |||
. Regulating means | . . Valves | . . . Lift valves | . . . . Solenoid valves | . . . Ball valves | . . Orifices or throttles | . . Constant oil gauges | . . Accumulators | . . Fluid elements | . . Valve operation mechanisms or operation circuits | |||
BB21 | BB22 | BB23 | BB24 | BB25 | BB26 | |||||||
. Control | . . Detection | . . . Flow detection | . . . Pressure detection | . . . Temperature detection | . . . Calorie detection | |||||||
CA | CA00 SUPPLY SYSTEM |
CA01 | CA04 | CA05 | CA06 | CA07 | ||||||
. Gas generators | . Piping | . . Pipes or hoses | . . Joints | . . Sealing devices | ||||||||
CA11 | CA12 | CA13 | CA14 | CA15 | CA16 | CA17 | CA18 | CA19 | CA20 | |||
. Pumping devices | . . Rotary pumps | . . . Gear pumps | . . . Screw pumps | . . Reciprocating pumps | . . . Electrodynamic pumps | . . . Diaphragm pumps | . . Air pumps | . . . Ejector pumps | . . Heat pumps | |||
CA21 | CA24 | CA25 | CA26 | CA27 | CA28 | CA29 | ||||||
. . Mounting devices of pumps | . Conduit systems | . . for vaporising burners | . . for spraying burners | . . having bypass conduits | . . having return conduits | . . having overflow conduits | ||||||
CB | CB00 FUEL TANK |
CB01 | CB02 | CB03 | CB04 | CB06 | CB07 | CB08 | CB10 | |||
. Independent tanks | . . Supply tanks | . . . Cartridge tanks | . . . . Disposable types | . Tanks integrated with combustion units | . . Pressurisation types e.g. for torch burners | . . having cartridge-tank receptacles | . having multiple tanks inside | |||||
CB11 | CB12 | CB13 | CB14 | CB15 | CB16 | CB17 | CB18 | |||||
. Detailed structure | . . Injection units or oil-supply caps | . . . having discharge functions | . . . Cap-turning tools | . . Discharge units | . . Ventilation structures | . . Handles | . . Supporting or mounting structure | |||||
CC | CC00 DETECTION OF LIQUID LEVELS |
CC01 | CC02 | CC05 | CC06 | CC07 | CC08 | CC09 | CC10 | |||
. Oil-amount detection | . Water detection | . Detecting means | . . Detection windows | . . Gauge pipes | . . using floats | . . detecting weights | . . detecting pressure | |||||
CC11 | CC12 | CC13 | CC14 | |||||||||
. . having light projectors or light receivers | . . having electrical detecting means | . . . by switching means | . . . having computation means | |||||||||
DA | DA00 SAFETY DEVICE |
DA01 | DA02 | DA03 | DA04 | DA06 | DA08 | DA09 | DA10 | |||
. Prevention of outflow or leakage | . . after flames have gone out | . Prevention of overheating | . . having heat-shielding or cooling means | . Backfire prevention | . against overturning | . against earthquakes | . against power failures | |||||
DA11 | DA12 | DA14 | DA16 | |||||||||
. Discrimination of different types of fuels | . Prevention of incorrect operations | . Safety valves | . Alarms or warnings | |||||||||
EA | EA00 SCOPE OF CLAIMS OR OTHERS |
EA01 | EA02 | EA03 | EA06 | EA07 | EA08 | |||||
. Claimed numerical limitation | . Claimed material limitation (free word) | . Process claims | . Cleaning | . . Purging | . Silencing | |||||||
F23N1/00-1/00,117@Z | FA | FA00 TIME OF REGULATION |
FA01 | FA02 | FA03 | FA04 | FA06 | FA07 | ||||
. at the time of starting e.g. at the time of ignition | . during operation | . . during load variation | . at the time of stopping e.g. at the time of flame extinguishing | . during abnormalities | . . during power failure | |||||||
FB | FB00 REGULATING MEANS |
FB01 | FB02 | FB03 | FB04 | FB05 | FB06 | FB07 | FB08 | FB09 | FB10 | |
. Valves | . . Proportional valves | . . On/off valves | . Cocks | . Governors | . Pumps | . Orifices or small holes | . Conduits | . . Return pipes | . . Bypass pipes | |||
FB11 | FB13 | FB14 | FB15 | FB16 | ||||||||
. Oil amount regulators | . Combinations of multiple regulating means | . interlocked with thermosensitive units | . Indicating mechanisms | . Remote control | ||||||||
FC | FC00 REGULATING SYSTEM |
FC01 | FC02 | FC03 | FC05 | FC06 | ||||||
. Mechanical | . Electrical | . . involving signal processing | . Manual | . Automatic | ||||||||
FD | FD00 REGULATED AMOUNT |
FD01 | FD02 | FD03 | FD04 | FD05 | FD06 | FD07 | FD08 | FD09 | FD10 | |
. for maintaining constant fuel supply amounts | . . ensuring minimum flow rates | . . Regulation of maximum flow rates | . Varying fuel supply amounts | . . Continuous e.g. proportional | . . On-off | . . stepwise e.g. switching capacities or the number of burners | . . Small to large e.g. slow ignition | . . Large to small | . adjusting to changes of fuel types e.g. gas type conversion or calorie conversion | |||
GA | GA00 FUEL DETECTION |
GA01 | GA02 | GA03 | GA04 | GA05 | GA07 | |||||
. Temperature | . Pressure | . Amount | . . Fuel level | . Components | . Detection of objects other than fuels | |||||||
HA | HA00 USE |
HA01 | HA02 | HA03 | HA05 | HA06 | HA07 | HA08 | ||||
. for industrial use | . . Boilers | . . Furnaces e.g. incinerators | . for domestic use | . . Water heaters e.g. water boilers | . . Air heaters e.g. stoves | . . Cooking devices | ||||||
JA | JA00 SUPPLY TYPE OF LIQUID FUELS |
JA01 | JA02 | JA03 | JA04 | JA05 | JA06 | JA07 | JA09 | JA10 | ||
. Vaporisation | . . Electric heating | . Atomisation | . . Ultrasonic atomisation | . . Rotary atomisation e.g. rotary burners | . . Pressurisation atomisation e.g. gun-type burners | . . Air-flow atomisation | . adjusting to fuel viscosity | . . Preheating of fuels | ||||
F23N5/26;5/26@F-5/26@R | KA | KA00 REMOTE-CONTROL SYSTEM |
KA01 | KA02 | KA03 | KA04 | KA06 | KA08 | KA10 | |||
. Remote control by cables or chains | . Remote control by connecting rods | . Electrical remote control for bath boilers | . Electrical remote control for hot water suppliers | . Remote control by means of light | . Remote control by means of sound | . Remote control by means of fluid pressure | ||||||
F23N5/26;5/26@F-5/26@R;5/26@Z | KB | KB00 CHARACTERISTIC STRUCTURE |
KB01 | KB02 | KB03 | KB05 | ||||||
. Assembly structures or mounting structures | . . Assembling or mounting by screws | . . Adjustable assembling or adjustable mounting | . Arrangement positions or storage parts | |||||||||
F23N5/26;5/26@F-5/26@Z | LA | LA00 OPERATING SYSTEM OF OPERATING PARTS |
LA01 | LA02 | LA03 | LA05 | LA06 | |||||
. Rotating operation | . Swinging operation or lever operation | . Thrusting operation or pulling operation | . operable by multiple operating parts | . . capable of remote control in addition to direct control | ||||||||
MA | MA00 CONTROLLED OBJECT |
MA01 | MA02 | MA04 | MA05 | MA07 | ||||||
. Main valves or main cocks | . Regulating valves for fuel flow rates e.g. governors or oil amount regulators | . Igniters e.g. electric discharge igniters | . . Pilot-light burners fuse burners or pilot-flame burners | . Water-supply valves or hot-water-supply valves | ||||||||
MB | MB00 CONTROL ELEMENT |
MB01 | MB02 | MB03 | MB04 | MB05 | MB06 | MB07 | MB08 | |||
. Locking means latching means or catching means | . Sprockets or chains | . Gears racks or pinions | . Clutches | . Cams | . Timers e.g. delay elements | . Electrical switches | . Flame detectors e.g. thermocouples | |||||
F23N5/26,101;5/26,101@A-5/26,101@Z | NA | NA00 DISPLAY SYSTEM |
NA01 | NA03 | NA04 | NA05 | NA06 | NA07 | NA08 | NA09 | NA10 | |
. with display means unspecified | . Visual display | . . Light-emitting means e.g. lamps or diodes | . . . Combinations of multiple light-emitting means | . . . Intermittent light emitting or flashing of lights | . . Symbols characters or numbers | . . Indication gauges | . . . Meters | . . Display by colour changes | ||||
NA13 | NA14 | NA15 | NA17 | NA19 | ||||||||
. Audible indication | . . Buzzers or bells | . . Voices or sounds e.g. loudspeakers | . Adjustment of the intensity of indication | . Switching of indication to different types of display indications | ||||||||
F23N5/26,101;5/26,101@E | PA | PA00 INDICATION OF COMBUSTION CONDITIONS OR IGNITION CONDITIONS |
PA01 | PA03 | PA04 | |||||||
. Indication of the presence of flames e.g. ignition or flameout | . Indication of combustion conditions e.g. intensity or quality | . . Abnormal combustion e.g. oxygen-deficient combustion | ||||||||||
F23N5/26,101;5/26,101@Z | PB | PB00 OTHER INDICATION |
PB01 | PB02 | PB03 | PB04 | PB05 | PB07 | ||||
. Indication of abnormal conditions | . . Failures or equipment life | . . Abnormalities in air-supply or ventilation systems | . . Abnormalities in fire-extinguishing systems | . . Abnormalities in the indoor atmosphere e.g. oxygen deficiency or gas leakage | . Indication of multiple information |