This page displays all 「FI」 in main group H02H7/00. |
HB:Handbook | ||||
CC:Concordance |
|
Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions [2006.01] | HB | CC | 5G053 | |
|
Power supply circuits, protecting arrangements (detecting power failures) | HB | CC | 5G053 | |
|
Protecting resistors, semiconductor elements, condensers or fuses (including those per se) | HB | CC | 5G053 | |
|
Protecting arrestors, lightening arrangements or surge absorbing elements (including those per se) | HB | CC | 5G053 | |
|
Protecting coils, solenoids or electromagnets | HB | CC | 5G053 | |
|
Protecting filters | HB | CC | 5G053 | |
|
Protecting hermetic electric instruments or cables | HB | CC | 5G053 | |
|
Protecting motors or generators (including control circuits) | HB | CC | 5G053 | |
|
Protecting reactors or transformers | HB | CC | 5G053 | |
|
Protecting heating equipment or air conditioning equipment | HB | CC | 5G053 | |
|
Protecting electric vehicles | HB | CC | 5G053 | |
|
Protections against contact melting | HB | CC | 5G053 | |
|
Others | HB | CC | 5G053 | |
|
.for transformers | HB | CC | 5G043 | |
|
for general transformers | HB | CC | 5G043 | |
|
.by detecting over-current (overloads, fuses) | HB | CC | 5G043 | |
|
.by detecting extraordinary temperatures (indicating only L) | HB | CC | 5G043 | |
|
.by detecting pressures | HB | CC | 5G043 | |
|
.by detecting leakage magnetic fluxes | HB | CC | 5G043 | |
|
.by detecting non-electric amounts such as sounds, lights or vibrations (temperatures C, pressures D) | HB | CC | 5G043 | |
|
.by indicating overloading | HB | CC | 5G043 | |
|
..Detecting and indicating overheating | HB | CC | 5G043 | |
|
for instrument transformers | HB | CC | 5G043 | |
|
for current transformers | HB | CC | 5G043 | |
|
for neon transformers | HB | CC | 5G043 | |
|
Others | HB | CC | 5G043 | |
|
..Differential protection of transformers [3] | HB | CC | 5G043 | |
|
General | HB | CC | 5G043 | |
|
Measures for rush-in current upon excitation | HB | CC | 5G043 | |
|
.Limiting or detecting harmonics | HB | CC | 5G043 | |
|
Measures for high passing currents | HB | CC | 5G043 | |
|
Combinations with other methods | HB | CC | 5G043 | |
|
Others (supervision, monitoring) | HB | CC | 5G043 | |
|
..for capacitive voltage transformers, e.g. against resonant conditions [3] | HB | CC | 5G043 | |
|
..for tapped transformers or tap-changing means thereof [3] | HB | CC | 5G043 | |
|
.for dynamo-electric generators; for synchronous capacitors | HB | CC | 5G044 | |
|
for charging generators, in-vehicle generators or self-excited generators | HB | CC | 5G044 | |
|
for speed generators | HB | CC | 5G044 | |
|
for turbine generators | HB | CC | 5G044 | |
|
for asynchronous generators (induction generators) | HB | CC | 5G044 | |
|
for DC generators | HB | CC | 5G044 | |
|
for synchronous generator fields | HB | CC | 5G044 | |
|
.for brushless fields | HB | CC | 5G044 | |
|
for failed stator (inside) of synchronous generators | HB | CC | 5G044 | |
|
for asynchronisation of synchronised generators | HB | CC | 5G044 | |
|
for cross current during parallel operation or reverse power of synchronous generators | HB | CC | 5G044 | |
|
for over-voltage or self-excitement of synchronous generators | HB | CC | 5G044 | |
|
for phase shorting or grounding of synchronous generators | HB | CC | 5G044 | |
|
Others | HB | CC | 5G044 | |
|
.for dynamo-electric motors | HB | CC | 5G044 | |
|
for starting resistances or reactors | HB | CC | 5G044 | |
|
for brushes or rectifiers | HB | CC | 5G044 | |
|
for multiple motors | HB | CC | 5G044 | |
|
for hysteresis motors | HB | CC | 5G044 | |
|
for synchronous, non-rectifier or pulse motors | HB | CC | 5G044 | |
|
.for brushless fields | HB | CC | 5G044 | |
|
.for asynchronisation | HB | CC | 5G044 | |
|
.for semiconductor controlled synchronous motors | HB | CC | 5G044 | |
|
for induction motors | HB | CC | 5G044 | |
|
.for secondary circuit faults; DC braking | HB | CC | 5G044 | |
|
.Protecting using slipping | HB | CC | 5G044 | |
|
.pole change motors | HB | CC | 5G044 | |
|
.for semiconductor controlled synchronous motors | HB | CC | 5G044 | |
|
for DC or AC rectifier motors | HB | CC | 5G044 | |
|
.for engine starting motors | HB | CC | 5G044 | |
|
.for semiconductor controlled DC motors | HB | CC | 5G044 | |
|
Others | HB | CC | 5G044 | |
|
..against excessive load | HB | CC | 5G044 | |
|
using thermal reaction switches | HB | CC | 5G044 | |
|
detecting winding temperatures by thermal sensitivity resistances | HB | CC | 5G044 | |
|
using changes in resonant frequencies or Q | HB | CC | 5G044 | |
|
detecting temperatures by measuring winding resistances | HB | CC | 5G044 | |
|
detecting temperatures | HB | CC | 5G044 | |
|
for DC or AC commutator motors | HB | CC | 5G044 | |
|
by detecting over-current (A to E take precedence.) | HB | CC | 5G044 | |
|
Others | HB | CC | 5G044 | |
|
..against over-voltage; against reduction of voltage; against phase interruption | HB | CC | 5G044 | |
|
for single phase or phase unbalancing | HB | CC | 5G044 | |
|
.using static relays | HB | CC | 5G044 | |
|
.directly detecting no-voltage or no-current between phases | HB | CC | 5G044 | |
|
.using differential relays; for detecting zero-phase or opposite phase component (B takes precedence.) | HB | CC | 5G044 | |
|
.using induction relays | HB | CC | 5G044 | |
|
for protecting both single phase and opposite phase | HB | CC | 5G044 | |
|
.using static relays | HB | CC | 5G044 | |
|
for over- or under-voltages | HB | CC | 5G044 | |
|
.for synchronous motors | HB | CC | 5G044 | |
|
.for multiple phase induction motors | HB | CC | 5G044 | |
|
.for single phase induction motors | HB | CC | 5G044 | |
|
.for DC or AC rectifier motors | HB | CC | 5G044 | |
|
Others | HB | CC | 5G044 | |
|
..against increase beyond, or decrease below, a predetermined level of rotational speed (centrifugal switches H01H 35/10) | HB | CC | 5G044 | |
|
for synchronous or non-rectifier motors | HB | CC | 5G044 | |
|
for three-phase induction motors | HB | CC | 5G044 | |
|
for single phase induction motors | HB | CC | 5G044 | |
|
for DC or AC non-rectifier motors | HB | CC | 5G044 | |
|
Others | HB | CC | 5G044 | |
|
..against wrong direction of rotation | HB | CC | 5G044 | |
|
for AC motors | HB | CC | 5G044 | |
|
.using vectors | HB | CC | 5G044 | |
|
.using mechanical means, rotary direction switches, speed generators or phase sequence rotary relays | HB | CC | 5G044 | |
|
for DC or non-rectifier motors | HB | CC | 5G044 | |
|
Others | HB | CC | 5G044 | |
|
.for converters; for rectifiers | HB | CC | 5G053 | |
|
..for static converters or rectifiers | HB | CC | 5G053 | |
|
for discharge tube converters | HB | CC | 5G053 | |
|
for elements or valves per se | HB | CC | 5G053 | |
|
.for GTO | HB | CC | 5G053 | |
|
.for over-voltages (C takes precedence.) | HB | CC | 5G053 | |
|
.detecting element failures (C takes precedence.) | HB | CC | 5G053 | |
|
for switching boards for feeding DC power | HB | CC | 5G053 | |
|
for DC-DC converters | HB | CC | 5G053 | |
|
for choppers | HB | CC | 5G053 | |
|
for cyclone converters | HB | CC | 5G053 | |
|
for AC phase controllers or semiconductor breakers | HB | CC | 5G053 | |
|
Others | HB | CC | 5G053 | |
|
...for inverters, i.e. dc/ac converters [2] | HB | CC | 5G053 | |
|
for parallel operation inverters | HB | CC | 5G053 | |
|
Others | HB | CC | 5G053 | |
|
...for rectifiers [2] | HB | CC | 5G053 | |
|
....having auxiliary control electrode to which blocking control voltages or currents are applied in case of emergency [2] | HB | CC | 5G053 | |
|
.for capacitors (for synchronous capacitors H02H 7/06) | HB | CC | 5G053 | |
|
responding to over-currents | HB | CC | 5G053 | |
|
responding to over-currents | HB | CC | 5G053 | |
|
.Fractional harmonics | HB | CC | 5G053 | |
|
responding to differential voltages or currents | HB | CC | 5G053 | |
|
responding to non-electrical amounts | HB | CC | 5G053 | |
|
Others | HB | CC | 5G053 | |
|
.for batteries; for accumulators | HB | CC | 5G053 | |
|
.for electronic equipment (for converters H02H 7/10; for electric measuring instruments G01R 1/36; for dc voltage or current semiconductor regulators G05F 1/569; for amplifiers H03F 1/52; for electronic switching circuits H03K 17/08) | HB | CC | 5G053 | |
|
for power supply circuits | HB | CC | 5G053 | |
|
.for constant voltage or current power supplies | HB | CC | 5G053 | |
|
for amplifier circuits | HB | CC | 5G053 | |
|
for electronic switching circuits | HB | CC | 5G053 | |
|
for communication arrangements | HB | CC | 5G053 | |
|
Protection elements accommodated in semiconductor elements | HB | CC | 5G053 | |
|
Others | HB | CC | 5G053 | |
|
.for distribution gear, e.g. bus-bar systems; for switching devices | HB | CC | 5G054 | |
|
for bus-bar systems | HB | CC | 5G054 | |
|
Others | HB | CC | 5G054 | |
|
.for spark-gap arresters | HB | CC | 5G054 | |
|
.Sectionalised protection of cable or line systems, e.g. for disconnecting a section on which a short-circuit, earth fault, or arc discharge has occurred (locating faults in cables G01R 31/08) | HB | CC | 5G054 | |
|
Shorting | HB | CC | 5G054 | |
|
Grounding | HB | CC | 5G054 | |
|
Electric leakage | HB | CC | 5G054 | |
|
Open wires | HB | CC | 5G054 | |
|
Detecting failed sections | HB | CC | 5G054 | |
|
.Indicating arrangements | HB | CC | 5G054 | |
|
Operating breakers | HB | CC | 5G054 | |
|
Operating section switches | HB | CC | 5G054 | |
|
.Fault operating arrangements | HB | CC | 5G054 | |
|
.Carrier wave devices | HB | CC | 5G054 | |
|
Digital processors | HB | CC | 5G054 | |
|
Others | HB | CC | 5G054 | |
|
..for meshed systems | HB | CC | 5G054 | |
|
..Staggered disconnection [3] | HB | CC | 5G054 | |