This page displays all 「FI」 in main group G01R33/00. |
HB:Handbook | ||||
CC:Concordance |
|
Arrangements or instruments for measuring magnetic variables | HB | CC | 2G017 | |
|
.Measuring direction or magnitude of magnetic fields or magnetic flux (G01R33/20 takes precedence) [4] | HB | CC | 2G017 | |
|
Characterised by detecting means | HB | CC | 2G017 | |
|
.by electromagnetic induction e.g. search coils (G01R33/02C to E take precedence) | HB | CC | 2G017 | |
|
.Wiegund wires | HB | CC | 2G017 | |
|
.by changes in inductance (G01R33/04 and G01R33/02E take precedence) | HB | CC | 2G017 | |
|
.by parametric oscillating (G01R33/04 takes precedence) | HB | CC | 2G017 | |
|
.by magnetic force, e.g. lead switches (G01R33/038 and G01R33/02G, H take precedence) | HB | CC | 2G017 | |
|
.using of magnet powders (for plotting field distribution, see G01R33/10) | HB | CC | 2G017 | |
|
.By magnetic strain | HB | CC | 2G017 | |
|
Characterised by amounts or object detected | HB | CC | 2G017 | |
|
.Detecting orientation, e.g. detection of magnetic field vector (G01R33/02M takes precedence) | HB | CC | 2G017 | |
|
.Detecting polarity | HB | CC | 2G017 | |
|
.Detecting rotating magnetic fields (G01R33/02P takes precedence) | HB | CC | 2G017 | |
|
.Detecting magnetic field of rotating electrical machines | HB | CC | 2G017 | |
|
.Detecting or searching moving objects (G01V takes precedence.) | HB | CC | 2G017 | |
|
.Biomagnetism (G01R33/035 takes precedence) | HB | CC | 2G017 | |
|
Casings, supporting devices | HB | CC | 2G017 | |
|
Magnetic flux guidance, magnetic flux focussing | HB | CC | 2G017 | |
|
Shields | HB | CC | 2G017 | |
|
Calibrating, compensating (see G01R35/00M) | HB | CC | 2G017 | |
|
Others | HB | CC | 2G017 | |
|
..Measuring gradient [3] | HB | CC | 2G017 | |
|
..Compensating stray fields [3] | HB | CC | 2G017 | |
|
..Electrodynamic magnetometers [3] | HB | CC | 2G017 | |
|
..using magneto-optic devices, e.g. Faraday [3] | HB | CC | 2G017 | |
|
..using superconductive devices [3] | HB | CC | 2G017 | |
|
..using permanent magnets, e.g. balances, torsion devices [3] | HB | CC | 2G017 | |
|
..using the flux-gate principle | HB | CC | 2G017 | |
|
...in thin-film element [3] | HB | CC | 2G017 | |
|
..using galvano-magnetic devices | HB | CC | 2G017 | |
|
...Hall-effect devices [6] | HB | CC | 2G017 | |
|
...Magneto-resistive devices [6] | HB | CC | 2G017 | |
|
..Plotting field distribution | HB | CC | 2G017 | |
|
.Measuring magnetic properties of articles or specimens of solids or fluids (involving magnetic resonance G01R33/20) [4] | HB | CC | 2G017 | |
|
Measuring magnets | HB | CC | 2G017 | |
|
Others | HB | CC | 2G017 | |
|
..Measuring or plotting hysteresis curves | HB | CC | 2G017 | |
|
..Measuring susceptibility | HB | CC | 2G017 | |
|
..Measuring magnetostrictive properties | HB | CC | 2G017 | |
|
.involving magnetic resonance (medical aspects A61B5/055;magnetic resonance gyrometers G01C19/60) [4, 5] | HB | CC | 2G017 | |
|
..Details, e.g. generation, homogenisation or stabilisation of magnetic fields (regulating magnetic variables in general G05F 7/00; electromagnets in general H01F 7/06) | HB | CC | 2G017 | |
|
..for measuring direction or magnitude of magnetic fields or magnetic flux [4] | HB | CC | 2G017 | |
|
...using optical pumping [4] | HB | CC | 2G017 | |
|
..Details of apparatus provided for in groups G01R33/44-G01R33/64 [5] | HB | CC | 2G044 | |
|
...Sample handling arrangements, e.g. sample cells, spinning mechanisms [5] | HB | CC | 2G044 | |
|
....Temperature control thereof [5] | HB | CC | 2G044 | |
|
...Excitation or detection systems, e.g. using radiofrequency signals [5] | HB | CC | 2G044 | |
|
....Structural details, e.g. resonators [5] | HB | CC | 2G044 | |
|
.....comprising surface coils [6] | HB | CC | 2G044 | |
|
......comprising arrays of sub-coils [6] | HB | CC | 2G044 | |
|
.....of slotted-tube or loop-gap type [6] | HB | CC | 2G044 | |
|
.....of waveguide type (G01R33/343 takes precedence) [6] | HB | CC | 2G044 | |
|
....Electrical details, e.g. matching or coupling of the coil to the receiver [5] | HB | CC | 2G044 | |
|
...Systems for generation, homogenisation or stabilisation of the main or gradient magnetic field [5] | HB | CC | 2G044 | |
|
....using electromagnets [6] | HB | CC | 2G044 | |
|
.....with superconducting coils, e.g. power supply therefor [6] | HB | CC | 2G044 | |
|
....using permanent magnets [6] | HB | CC | 2G044 | |
|
....using gradient magnetic field coils [6] | HB | CC | 2G044 | |
|
....Compensation of inhomogeneities [6] | HB | CC | 2G044 | |
|
.....using ferromagnetic bodies [6] | HB | CC | 2G044 | |
|
.....using correction coil assemblies, e.g. active shimming [6] | HB | CC | 2G044 | |
|
....Field stabilisation [6] | HB | CC | 2G044 | |
|
...Screening [5, 6] | HB | CC | 2G044 | |
|
....of main or gradient magnetic field [6] | HB | CC | 2G044 | |
|
....of the radiofrequency field [6] | HB | CC | 2G044 | |
|
..using nuclear magnetic resonance [NMR] (G01R33/24, G01R33/62 take precedence) [5] | HB | CC | 2G044 | |
|
...NMR spectroscopy [5] | HB | CC | 2G044 | |
|
....applied to biological material, e.g. testing within glass containers, i.e. in vitro testing [6] | HB | CC | 2G044 | |
|
...NMR imaging systems [5] | HB | CC | 2G044 | |
|
....with selection of signal or spectra from particular regions of the volume, e.g. spectroscopy for living body, i.e. in vivo spectroscopy [6] | HB | CC | 2G044 | |
|
.....based on chemical shift information [6] | HB | CC | 2G044 | |
|
....based on the determination of relaxation times [5] | HB | CC | 2G044 | |
|
....Signal processing systems, e.g. using pulse sequences [5] | HB | CC | 2G044 | |
|
.....Image enhancement or correction, e.g. subtraction or averaging techniques [5] | HB | CC | 2G044 | |
|
......by reduction of the scanning time, i.e. fast acquiring systems, e.g. using echo-planar pulse sequences [6] | HB | CC | 2G044 | |
|
......of moving material, e.g. flow-contrast angiography, i.e. angiography [6] | HB | CC | 2G044 | |
|
......Correction of image distortions, e.g. due to magnetic field inhomogeneities [6] | HB | CC | 2G044 | |
|
......gated by physiological signals [6] | HB | CC | 2G044 | |
|
....Calibration of imaging systems, e.g. using test probes [5] | HB | CC | 2G044 | |
|
..using electron paramagnetic resonance (G01R33/24, G01R33/62 take precedence) [5] | HB | CC | 2G044 | |
|
..using double resonance (G01R33/24 takes precedence) [5] | HB | CC | 2G044 | |
|
..using cyclotron resonance (G01R33/24 takes precedence) [5] | HB | CC | 2G044 | |