This page displays all 「FI」 in main group G01F1/00. |
HB:Handbook | ||||
CC:Concordance |
|
Measuring the volume flow or mass flow of fluid or fluent solid material wherein the fluid passes through a meter in a continuous flow (measuring a proportion of the volume flow G01F 5/00) [1, 2, 2006.01, 2022.01] | HB | CC | 2F030 | |
|
Special flow meters | HB | CC | 2F030 | |
|
Characterised by detecting methods | HB | CC | 2F030 | |
|
.Methods for estimating flow e.g. from water levels | HB | CC | 2F030 | |
|
Calculating flow using of special detecting devices e.g. light | HB | CC | 2F030 | |
|
Consider flow velocity distribution | HB | CC | 2F030 | |
|
Applying to special fluids | HB | CC | 2F030 | |
|
.Special gases | HB | CC | 2F030 | |
|
.Special fluids, e.g. clay | HB | CC | 2F030 | |
|
..For nuclear reactors, e.g. Na, H | HB | CC | 2F030 | |
|
..Fr blast furnaces, e.g. Fe, Ne | HB | CC | 2F030 | |
|
..For medical, e.g. blood, humors | HB | CC | 2F030 | |
|
Items common to flow meters | HB | CC | 2F030 | |
|
characterised by detecting units e.g. sensors | HB | CC | 2F030 | |
|
.Using of supplemental tubes, e.g. side tubes, bypass tubes | HB | CC | 2F030 | |
|
.Detecting leakage, detecting shutoff, detecting abnormalities, safety devices | HB | CC | 2F030 | |
|
.Galvanometers (galvanometers per se G01P13/00) | HB | CC | 2F030 | |
|
Switching flow meters, e.g. different types, switching ranges (compound meters G01F7/00) | HB | CC | 2F030 | |
|
Calculating flow, e.g. calculating circuits | HB | CC | 2F030 | |
|
Compensating instrument errors, e.g. temperature, pressure compensations | HB | CC | 2F030 | |
|
Regulating flow | HB | CC | 2F030 | |
|
Indicating, e.g. remote indicating | HB | CC | 2F030 | |
|
characterised by accessory or mounting members e.g. filters | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
.wherein the flow is in an open channel [2022.01] | HB | CC | 2F030 | |
|
.by using mechanical effects [2, 2006.01] | HB | CC | 2F030 | |
|
..using rotating vanes with tangential admission [2] | HB | CC | 2F030 | |
|
Single-box water meters | HB | CC | 2F030 | |
|
Multi-box water meters | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
...with mechanical coupling to the indicating device [2] | HB | CC | 2F030 | |
|
...with magnetic or electromagnetic coupling to the indicating device [2] | HB | CC | 2F030 | |
|
...Adjusting, correcting, or compensating means therefor [2] | HB | CC | 2F030 | |
|
..using rotating vanes with axial admission [2] | HB | CC | 2F030 | |
|
...with mechanical coupling to the indicating device [2] | HB | CC | 2F030 | |
|
...with magnetic or electromagnetic coupling to the indicating device [2] | HB | CC | 2F030 | |
|
...Adjusting, correcting, or compensating means therefor | HB | CC | 2F030 | |
|
..by detection of dynamic effects of theflow [2, 2006.01] | HB | CC | 2F030 | |
|
Detecting dynamic effects in general | HB | CC | 2F030 | |
|
.detecting sphere movements | HB | CC | 2F030 | |
|
.detecting vane movements, vane flow meters | HB | CC | 2F030 | |
|
.detecting vibrations of members (swirl flowmeter G01F1/32) | HB | CC | 2F030 | |
|
.fluidic flow meter | HB | CC | 2F030 | |
|
.detecting falling profiles, positions of a flow | HB | CC | 2F030 | |
|
.counting droplets, minute flow meters | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
...by variable-area meters [2] | HB | CC | 2F030 | |
|
using of tapered tubes | HB | CC | 2F030 | |
|
Displacing floats, pressure receiving plates by spring | HB | CC | 2F030 | |
|
characterised by structure of floats, pressure receiving plates | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
....with magnetic or electric coupling to the indicating device [2] | HB | CC | 2F030 | |
|
....of the valve type [2] | HB | CC | 2F030 | |
|
...by drag-force, e.g. vane type or impact flowmeter [2] | HB | CC | 2F030 | |
|
Rotating pressure receiving plates | HB | CC | 2F030 | |
|
Pressure receiving plates moving back and forth | HB | CC | 2F030 | |
|
Elastically deforming pressure receiving plates | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
....for fluent solid material [2] | HB | CC | 2F030 | |
|
...using swirl flowmeters [2, 2006.01, 2022.01] | HB | CC | 2F004 | |
|
Karman types in general | HB | CC | 2F004 | |
|
.profiles of vortex generator | HB | CC | 2F004 | |
|
.supplemental bodies for generating vortices, e.g. characterised by passages | HB | CC | 2F004 | |
|
.Signal processing circuits | HB | CC | 2F004 | |
|
.characterized by cleaning | HB | CC | 2F004 | |
|
.characterized by mounting | HB | CC | 2F004 | |
|
Swirl types | HB | CC | 2F004 | |
|
Others | HB | CC | 2F004 | |
|
....Means for detecting quantities used as proxy variables for swirl [2022.01] | HB | CC | 2F004 | |
|
having members for detection on the side | HB | CC | 2F004 | |
|
with pressure guide holes | HB | CC | 2F004 | |
|
.characterised by diaphragms | HB | CC | 2F004 | |
|
.using temperature-sensitive elements | HB | CC | 2F004 | |
|
.using light | HB | CC | 2F004 | |
|
.using magnetic force | HB | CC | 2F004 | |
|
Distortion of vibrating members disposed in a flow path, e.g. distortion of vortex generators per se | HB | CC | 2F004 | |
|
.with pressure-sensitive elements, e.g. strain gauges | HB | CC | 2F004 | |
|
.using light | HB | CC | 2F004 | |
|
.Detecting changes in magnetic forces | HB | CC | 2F004 | |
|
.Detecting changes in capacitance | HB | CC | 2F004 | |
|
.Detection with tuning forks | HB | CC | 2F004 | |
|
Detecting vortexes per se, e.g. ultrasonic waves | HB | CC | 2F004 | |
|
Others | HB | CC | 2F004 | |
|
..by measuring pressure or differential pressure [2] | HB | CC | 2F030 | |
|
By single pressure measurement | HB | CC | 2F030 | |
|
Bent tube flow meters | HB | CC | 2F030 | |
|
Sonic nozzle flow meters | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
...the pressure or differential pressure being created by the use of flow constriction [2] | HB | CC | 2F030 | |
|
....the pressure or differential pressure being measured by means of communicating tubes or reservoirs with movable fluid levels, e.g. by U-tubes [2] | HB | CC | 2F030 | |
|
....the pressure or differential pressure being measured by means of a movable element, e.g. diaphragm, piston, Bourdon tube or flexible capsule [2] | HB | CC | 2F030 | |
|
....Details of construction of the flow constriction devices [2] | HB | CC | 2F030 | |
|
.....Orifices or nozzles [2] | HB | CC | 2F030 | |
|
Using of orifice plates | HB | CC | 2F030 | |
|
Using of nozzles | HB | CC | 2F030 | |
|
Using of variable orifices | HB | CC | 2F030 | |
|
Using of special orifices | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
.....Venturi tubes [2] | HB | CC | 2F030 | |
|
.....Pitot tubes [2] | HB | CC | 2F030 | |
|
...the pressure or differential pressure being created by a capillary element [2] | HB | CC | 2F030 | |
|
...Correcting or compensating means [2] | HB | CC | 2F030 | |
|
..by measuring the height of the fluid level due to the lifting power of the fluid flow [2] | HB | CC | 2F030 | |
|
Flume type flow meters | HB | CC | 2F030 | |
|
Weir type flow meters | HB | CC | 2F030 | |
|
Others | HB | CC | 2F030 | |
|
..by means of chains, flexible bands, or wires introduced into, and moved by, the flow [2] | HB | CC | 2F030 | |
|
.by using electric or magnetic effects (G01F 1/66 takes precedence) [2] | HB | CC | 2F035 | |
|
..by electromagnetic flowmeters [2] | HB | CC | 2F035 | |
|
Conduits I, e.g. linings | HB | CC | 2F035 | |
|
Conduits II, e.g. flanges, connections | HB | CC | 2F035 | |
|
Electrodes I, e.g. structures; cleaning | HB | CC | 2F035 | |
|
Electrodes II, e.g. multiple electrodes | HB | CC | 2F035 | |
|
Generating magnetic fields, e.g. coils, cores, magnets | HB | CC | 2F035 | |
|
.Uneven magnetic fields | HB | CC | 2F035 | |
|
.Spreading magnetic fields | HB | CC | 2F035 | |
|
Grounding | HB | CC | 2F035 | |
|
Grounding, e.g. terminal boxes, terminate plates | HB | CC | 2F035 | |
|
Detecting wear | HB | CC | 2F035 | |
|
Compensating noises | HB | CC | 2F035 | |
|
Lead wires | HB | CC | 2F035 | |
|
Detecting less-than-full water levels | HB | CC | 2F035 | |
|
Shielded drives | HB | CC | 2F035 | |
|
Calibrating | HB | CC | 2F035 | |
|
Inserted types | HB | CC | 2F035 | |
|
Immersed types | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
...Circuits therefor [2] | HB | CC | 2F035 | |
|
..by measuring electrical currents passing through the fluid flow; by measuring electrical potential generated by the fluid flow, e.g. by electrochemical, contact, or friction effects (G01F 1/58 takes precedence) [2] | HB | CC | 2F035 | |
|
.by measuring frequency, phase shift or propagation time of electromagnetic or other waves, e.g. using ultrasonic flowmeters [2, 2006.01, 2022.01] | HB | CC | 2F035 | |
|
Multiple measurement lines; averaging; open channels | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
..by measuring wave transmission time or phase difference in fluids | HB | CC | 2F035 | |
|
...by sing-around method | HB | CC | 2F035 | |
|
..using light [2022.01] | HB | CC | 2F035 | |
|
..by measuring Doppler frequency shift [2022.01] | HB | CC | 2F035 | |
|
..Arrangements of transducers for ultrasonicflowmeters; Circuits for operating ultrasonicflowmeters [2022.01] | HB | CC | 2F035 | |
|
Arrangement and attachment of the oscillators of ultrasonic flowmeters | HB | CC | 2F035 | |
|
Structures of the oscillators of ultrasonic flowmeters | HB | CC | 2F035 | |
|
Circuits to make ultrasonic flowmeters operative | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
.by using thermal effects [2] | HB | CC | 2F035 | |
|
Characteristic having measurement of suction air amount of car engine | HB | CC | 2F035 | |
|
Detection of failure and trouble | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
..Structural arrangements; Mounting of elements, e.g. in relation to fluid flow [6] | HB | CC | 2F035 | |
|
Main body of sensor | HB | CC | 2F035 | |
|
Flow path | HB | CC | 2F035 | |
|
Rectification member | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
...using a particular type of heating, cooling or sensing element [6] | HB | CC | 2F035 | |
|
....of resistive type [6] | HB | CC | 2F035 | |
|
Characteristic having shape | HB | CC | 2F035 | |
|
Characteristic having material | HB | CC | 2F035 | |
|
Characteristic having manufacturing process | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
.....Thin-film arrangements [6] | HB | CC | 2F035 | |
|
Characteristic having shape | HB | CC | 2F035 | |
|
Characteristic having material | HB | CC | 2F035 | |
|
Characteristic having manufacturing process | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
..Circuits therefor, e.g. constant-current flow meters [6] | HB | CC | 2F035 | |
|
Characteristic having sensor element (construction G01F1/684) | HB | CC | 2F035 | |
|
Characteristic having differential amplifier | HB | CC | 2F035 | |
|
Characteristic having drive power source | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
...Feedback or rebalancing circuits, e.g. self heated constant temperature flowmeters [6] | HB | CC | 2F035 | |
|
Characteristic having sensor element (construction G01F1/684) | HB | CC | 2F035 | |
|
Characteristic having differential amplifier | HB | CC | 2F035 | |
|
Characteristic having drive power source | HB | CC | 2F035 | |
|
Others | HB | CC | 2F035 | |
|
....by control of a separate heating or cooling element [6] | HB | CC | 2F035 | |
|
.using marked regions or existing inhomogeneities within the fluid stream, e.g. statistically occurring variations in a fluid parameter (G01F 1/76,G01F 25/00 take precedence) [4, 2006.01] | HB | CC | 2F035 | |
|
..Measuring the time taken to traverse a fixed distance [4, 2006.01, 2022.01] | HB | CC | 2F035 | |
|
...using acoustic detecting arrangements [2022.01] | HB | CC | 2F035 | |
|
...using thermal detecting arrangements [2022.01] | HB | CC | 2F035 | |
|
...using optical detecting arrangements [2022.01] | HB | CC | 2F035 | |
|
...using electrically charged particles astracers [2022.01] | HB | CC | 2F035 | |
|
...using auto-correlation or cross-correlation detection means [4, 2006.01] | HB | CC | 2F035 | |
|
...using electron paramagnetic resonance [EPR] or nuclear magnetic resonance [NMR] [2006.01] | HB | CC | 2F035 | |
|
.Devices for measuring pulsing fluid flows [2] | HB | CC | 2F035 | |
|
.Devices for measuring flow of a fluid or flow of a fluent solid material in suspension in another fluid [2] | HB | CC | 2F035 | |
|
.Devices for measuring mass flow of a fluid or a fluent solid material [2] | HB | CC | 2F035 | |
|
..Direct mass flowmeters [2] | HB | CC | 2F035 | |
|
...operating by measuring pressure, force, momentum, or frequency of a fluid flow to which a rotational movement has been imparted [2] | HB | CC | 2F035 | |
|
....using a driven wheel as impeller and one or more other wheels or moving elements which are angularly restrained by a resilient member, e.g. spring member, as the measuring device [2] | HB | CC | 2F035 | |
|
....Coriolis or gyroscopic mass flowmeters [2] | HB | CC | 2F035 | |
|
..Indirect mass flowmeters, e.g. measuring volume flow and density, temperature, or pressure [2] | HB | CC | 2F035 | |
|
...with differential-pressure measurement to determine the volume flow [2] | HB | CC | 2F035 | |
|
...with positive-displacement meter or turbine meter to determine the volume flow [2] | HB | CC | 2F035 | |