| 4C096 | MAGNETIC RESONANCE IMAGING APPARATUS | |
| A61B5/055 -5/055,400 | ||
| A61B5/055-5/055,400 | AA | AA00 USE |
AA01 | AA02 | AA03 | AA04 | AA05 | AA06 | AA07 | AA08 | AA09 | AA10 |
| . Topography | . . Stationary images | . . T1 images including T1-weighted images | . . T2 images including T2-weighted images | . . Images of proton densities | . . Images of chemical shifts | . . . Water-fat separated images | . . Cine images | . . . Cardiac cine images | . . Angiography | |||
| AA11 | AA12 | AA13 | AA14 | AA15 | AA17 | AA18 | AA20 | |||||
| . Photographing using contrast preparations | . Photographing fluoroscopic images | . Spectroscopy | . Spectroscopic imaging | . . of particular elements * | . Diffusion or perfusion | . combined with other apparatus * | . Others * | |||||
| AB | AB00 PURPOSE |
AB01 | AB02 | AB03 | AB04 | AB05 | AB06 | AB07 | AB08 | AB09 | ||
| . Improving image quality | . . of spatial resolution or having high definition data | . . of time resolution or having high frame rate | . . of density resolutions or contrasts | . . removing or correcting distortions | . . . caused by eddy currents | . . reducing noises and improving the signal to noise ratio | . . of sharpness | . . for uniforming quality | ||||
| AB11 | AB12 | AB13 | AB14 | AB15 | AB16 | AB17 | AB18 | AB19 | AB20 | |||
| . Removing artifacts | . . caused by body motion including respiration | . . caused by flow | . . caused by chemical shifts | . . caused by aliasing | . . . in the directions of frequencies | . . . in the directions of phases | . . caused by inhomogeneous magnetic fields | . . of truncation | . . Shading | |||
| AB22 | AB24 | AB25 | AB26 | AB27 | AB29 | |||||||
| . . of DC or low frequency noises | . Acceleration of photographing | . . of collecting data | . . of reconstruction operation | . . of image processing | . of image transfer | |||||||
| AB31 | AB32 | AB33 | AB34 | AB36 | AB37 | AB38 | AB39 | |||||
| . Improvement of magnetic field characteristics | . . of static magnetic fields | . . of gradient magnetic fields | . . of radiofrequency fields | . Improvement of operability | . . by facilitating handling of the apparatus | . . by automation | . . of photographing efficiencies or throughputs | |||||
| AB41 | AB42 | AB43 | AB44 | AB45 | AB46 | AB47 | AB48 | AB50 | ||||
| . Adding functions to the apparatus | . Miniaturising simplifying or reducing costs of the apparatus | . Energy saving | . Improving reliability | . Improving maintainability; Facilitating adjustment | . Improving safety of patients or operators | . Improving patients' environments | . Improving shielding performance | . Others * | ||||
| AC | AC00 REGION |
AC01 | AC02 | AC03 | AC04 | AC05 | AC06 | AC07 | AC08 | AC10 | ||
| . Heads including faces | . . Orbits | . Necks | . Chests or hearts | . Abdomens | . Spines or spinal cords | . Lumbar regions | . Extremities including knee joints | . Others * | ||||
| AD | AD00 CONTROLLING |
AD01 | AD02 | AD03 | AD05 | AD06 | AD07 | AD08 | AD09 | AD10 | ||
| . Types of controlling | . . of single apparatus or systems | . . of multiple apparatus or systems | . Objects to be controlled | . . Pulse sequences | . . Scanning conditions | . . Static magnetic field systems or bodies thereof | . . Gradient magnetic field systems | . . Radiofrequency transmitting and receiving systems or RF coils | ||||
| AD12 | AD13 | AD14 | AD15 | AD16 | AD17 | AD18 | AD19 | |||||
| . . Collecting processing or transmitting data | . . Reconstructing images | . . Processing images | . . Indicating or outputting images or the like | . . Recording transmitting or storing images | . . Indicating operations or conditions | . . Supporting travelling or fastening subjects | . . Accessories or facilities | |||||
| AD21 | AD22 | AD23 | AD24 | AD25 | AD26 | AD27 | AD28 | AD29 | AD30 | |||
| . Systems for producing signals for control | . . with switches or by switch operation | . . sequentially by behaviours of apparatus | . . Preset systems including memory type programmes | . . based on comparisons between signals | . . using signals of synchronising signal sources | . . . Biological signals | . . . TV synchronising signals | . . using speech signals | . Others * | |||
| BA | BA00 PULSE SEQUENCE |
BA01 | BA02 | BA03 | BA04 | BA05 | BA06 | BA07 | BA08 | BA09 | BA10 | |
| . Flip angles of 90 degrees | . Flip angles of less than 90 degrees | . Using FID signals | . Using echo signals | . . by 180 degree pulses | . . by gradient magnetic fields | . . Multiple echo signals | . . Timing of generating echo signals | . . . Half-echoes | . . encoding echo signals | |||
| BA12 | BA13 | BA15 | BA16 | BA18 | BA19 | BA20 | ||||||
| . . . Half-encoding | . . . Encoding orders | . Multiple slice scanning | . . Multiple-angle scanning | . 3D scanning | . Inverting spins before excitation | . Presaturation | ||||||
| BA21 | BA22 | BA23 | BA24 | BA25 | BA26 | BA27 | ||||||
| . Flow compensation | . Body motion compensation | . Forced recovery | . Steady-state scanning | . Using spoiler pulses | . Rewinding warp gradients in single TR | . Cancelling all gradient magnetic fields in single TR | ||||||
| BA31 | BA32 | BA33 | BA34 | BA36 | BA37 | BA38 | ||||||
| . Selecting regions | . . in the biaxial directions | . . in the triaxial directions | . . . of volumes | . Flow imaging or angiographies | . . Time-of-flight methods | . . Phase contrast methods | ||||||
| BA41 | BA42 | BA50 | ||||||||||
| . High speed scanning | . Very high speed scanning e.g. echo-planar imaging | . Others * | ||||||||||
| BB | BB00 SCANNING CONDITION |
BB01 | BB02 | BB03 | BB05 | BB06 | BB07 | BB08 | BB10 | |||
| . Pulse waveforms | . . to gradient pulses | . . of RF pulses | . Time constants | . . TR | . . TE | . . TI | . Flip angles | |||||
| BB11 | BB12 | BB13 | BB14 | BB15 | BB16 | BB18 | BB19 | |||||
| . Number of echoes | . Slice constants | . . Number of slices | . . Thicknesses of slices | . . Intervals of slices | . . Angles of slices | . Fields of views or FOV | . . Thicknesses of slabs | |||||
| BB21 | BB22 | BB23 | BB24 | BB25 | BB27 | BB28 | BB29 | BB30 | ||||
| . Scan planes | . . Axial imaging | . . Sagittal imaging | . . Coronal imaging | . . Oblique imaging | . Average number | . Image matrices | . . Number of views | . . Number of samples | ||||
| BB31 | BB32 | BB40 | ||||||||||
| . Automatic setting | . . by test scanning before main scanning | . Others * | ||||||||||
| CA | CA00 STATIC MAGNETIC FIELD SYSTEM OR BODY THEREOF |
CA01 | CA02 | CA03 | CA04 | CA05 | CA06 | CA07 | CA08 | CA09 | CA10 | |
| . Magnets | . . Superconducting magnets | . . Resistive electromagnets or electromagnets | . . . Air-core magnets | . . Permanent magnets | . . . Magnets per se | . . . Pole pieces | . . . Yokes | . . . . in the shape of C | . . . . in the shape of H | |||
| CA12 | CA14 | CA15 | CA16 | CA17 | CA18 | |||||||
| . . Hybrid magnets | . Directions of magnetic fields | . . horizontal | . . vertical | . . parallel to the axes of subjects | . . crossing the axes of subjects | |||||||
| CA21 | CA22 | CA23 | CA24 | CA25 | CA26 | CA27 | CA29 | |||||
| . Adjusting homogeneities of magnetic fields | . . by superconducting coils | . . by resistive coils | . . by permanent magnets | . . by steel pieces | . . CSI shimming | . . automatically | . Detecting magnetic fields | |||||
| CA31 | CA32 | CA33 | CA34 | CA35 | CA36 | CA38 | CA39 | CA40 | ||||
| . Structures or arrangement of coils | . . of static magnetic fields | . . . Solenoid types | . . . Double Helmholtz types | . . Shim coils | . . Supporting or attaching coils | . Magnetic shields | . . Active types | . . . by superconducting coils | ||||
| CA42 | CA43 | CA44 | CA47 | CA48 | CA49 | |||||||
| . . Passive types | . . . by yokes for self-shielding | . . . by cages | . Power supplies or circuits for magnetisation | . . of superconducting magnets | . . of constant currents for resistive electromagnets | |||||||
| CA51 | CA52 | CA53 | CA54 | CA55 | CA56 | CA58 | CA59 | CA60 | ||||
| . Isothermal apparatus e.g. for temperature control | . . Cryostats | . . . heat shielding | . . . freezing cryostats | . . involving resistive electromagnets | . . involving permanent magnets | . Structures of bodies | . . Frames | . . Covers | ||||
| CA62 | CA63 | CA64 | CA65 | CA66 | CA67 | CA68 | CA70 | |||||
| . . RF shields | . . Environments of patient receiving spaces | . . . Lighting | . . . Fields of vision | . . . Sounds | . . . . Insulation of sounds | . . . Air conditioning | . Others * | |||||
| CB | CB00 GRADIENT MAGNETIC FIELD SYSTEM |
CB01 | CB02 | CB03 | CB04 | CB05 | CB06 | CB07 | CB08 | CB09 | CB10 | |
| . Structures or arrangement of gradient coils | . . Helmholtz types | . . Saddle types | . . Spiral types | . . Types for cancelling external magnetic fields | . . Resonance types | . . Supporting or attaching coils | . Generating gradient pulse waveforms | . . analogue | . . digital | |||
| CB11 | CB12 | CB13 | CB16 | CB17 | CB19 | CB20 | ||||||
| . Gradient power supplies | . . Power amplifiers | . . . Switching systems | . Correcting eddy currents | . . by waveforms of gradient pulses | . Suppressing coil vibration sounds | . Others * | ||||||
| CC | CC00 RADIOFREQUENCY TRANSMITTING SYSTEM OR RF COIL |
CC01 | CC02 | CC03 | CC04 | CC05 | CC06 | CC07 | CC08 | CC09 | CC10 | |
| . Structures or arrangement of RF coils | . . Saddle types | . . Solenoid types | . . Slot resonator types | . . Bird cage types | . . Phased array type | . . Quadrature types | . . Surface coils | . . . for specific regions * | . . . inserted into body cavities | |||
| CC12 | CC13 | CC14 | CC15 | CC16 | CC17 | CC18 | CC19 | CC20 | ||||
| . . Supporting or attaching coils | . . for managing coil cables | . Circuits of RF coils | . . Tuning or synchronising | . . Decoupling | . . Connecting or switching coils | . Baluns | . Generating RF signals | . . Reference oscillators | ||||
| CC22 | CC23 | CC24 | CC26 | CC27 | CC29 | CC30 | ||||||
| . . Synthesisers | . . Mixers | . . Band limiting | . Generating waveforms of excitation pulses | . . Digital systems | . Pulse modulations | . Gates | ||||||
| CC31 | CC32 | CC33 | CC34 | CC37 | CC38 | CC40 | ||||||
| . Adjusting phases | . Power amplifying; Driving | . . Driving quadrature coils | . . Monitors of output levels | . Adjusting load impedances | . Adjusting strength of radiofrequency fields | . Others * | ||||||
| CD | CD00 RADIOFREQUENCY RECEIVING SYSTEM |
CD01 | CD02 | CD03 | CD04 | CD05 | CD06 | CD07 | CD08 | CD09 | CD10 | |
| . Amplifying | . . Pre-amplifying | . . Gain adjustment | . Gates | . Frequency conversion | . Band limiting | . Detecting phases | . . digitally | . . Quadrature detection | . Others * | |||
| DA | DA00 COLLECTING, PROCESSING, OR TRANSMITTING DATA |
DA01 | DA02 | DA03 | DA04 | DA05 | DA06 | DA08 | DA09 | |||
| . Sampling | . AD conversion | . Storing data temporarily | . Correcting | . . Offset correction | . . Phase correction | . Filtering | . . Digital filters | |||||
| DA11 | DA12 | DA13 | DA14 | DA15 | DA17 | DA18 | DA19 | DA20 | ||||
| . Mean | . Sorting | . Thinning | . Interpolation | . Weighing | . Collecting biosignals | . . Electrocardiogram signals | . . Respiratory signals | . . Peripheral or pulse wave signals | ||||
| DA21 | DA22 | DA23 | DA24 | DA30 | ||||||||
| . Transmitting data | . . optically | . . Parallel-serial conversions | . . Serial-parallel conversions | . Others * | ||||||||
| DB | DB00 IMAGE RECONSTRUCTION |
DB01 | DB02 | DB03 | DB04 | DB06 | DB07 | DB08 | DB09 | DB10 | ||
| . Reconstruction techniques | . . Two-dimensional Fourier transform methods | . . Three-dimensional Fourier transform methods | . . Projection restoration methods | . Image calculations | . Operation processing | . . of projection data | . . . making composite data or secondary data | . . Fourier transform operation | ||||
| DB12 | DB13 | DB14 | DB15 | DB16 | DB17 | DB18 | DB19 | DB20 | ||||
| . . characterised by the procedures of operation execution | . . . High-speed operation systems | . . . . Processing in parallel | . . . . Pipeline processing | . Images without aliasing | . . in the frequency directions | . . in the phase directions | . Setting fields of vision at the time of reconstructing images | . Others * | ||||
| DC | DC00 IMAGE PROCESSING |
DC01 | DC02 | DC03 | DC04 | DC05 | DC06 | DC08 | DC09 | |||
| . for correcting deterioration of image quality | . . correcting distortions | . . . of densities | . . . of phases | . . removing noises | . . restoring blurred images | . for correcting uniformities | . . Smoothing | |||||
| DC11 | DC12 | DC14 | DC15 | DC16 | DC18 | DC19 | DC20 | |||||
| . Enhancement processing including suppressing | . . Gradation conversions or greyscale conversions | . Geometrical transformation processing | . . by movements e.g. translations or rotations | . . by enlarging or reducing | . for detecting objects e.g. clipping | . . Profiles | . . Lesioned sections | |||||
| DC21 | DC22 | DC23 | DC24 | DC25 | DC27 | DC28 | DC29 | DC30 | ||||
| . for detecting characteristics | . for measuring or analysing based on images | . . Distances or lengths | . . Areas or volumes | . . Dynamic analyses | . for setting regions | . . Regions of interest (ROI) | . for density resolutions | . . Windows e.g. widths or levels | ||||
| DC31 | DC32 | DC33 | DC35 | DC36 | DC37 | DC38 | DC40 | |||||
| . for multiple images | . . Multiframes | . . between images | . for making special images | . . Three-dimensional images | . . indicating desired cross-section | . . Images composed of laminated multiple slice images | . Others * | |||||
| DD | DD00 INDICATING OR OUTPUTTING IMAGE OR THE LIKE |
DD01 | DD02 | DD03 | DD04 | DD05 | DD06 | DD07 | DD08 | DD09 | DD10 | |
| . Indicating devices | . . having multiple indicating devices | . . Resolution or indication speeds | . . CRTs | . . Flat displays | . Controlling luminance | . Colour indications | . Interactive input devices e.g. light pens | . . Joysticks track balls or the like | . . Touch panels | |||
| DD11 | DD12 | DD13 | DD14 | DD15 | DD16 | DD18 | DD19 | DD20 | ||||
| . Auxiliary indications | . . of scales | . . of markers | . . of graphs | . . of biological signals | . . of numerical values or characters | . Outputting diagnostic reports | . Indications or outputs by speeches | . Others * | ||||
| DE | DE00 RECORDING, TRANSMITTING, OR STORING IMAGE |
DE01 | DE02 | DE03 | DE04 | DE05 | DE06 | DE07 | DE08 | DE09 | DE10 | |
| . Compressing or restoring data | . Temporary storages by memory | . . corresponding to additional information | . Digital records e.g. optical discs or digital disc recorders (DDR) | . Analogue records e.g. video tape recorders (VTR) | . Transmissions e.g. optical transmissions or interfaces | . Image database | . . Data accesses or retrievals | . Giving data identification information | . Others * | |||
| EA | EA00 INDICATING BEHAVIOUR OR CONDITION |
EA01 | EA02 | EA03 | EA04 | EA05 | EA06 | EA07 | EA10 | |||
| . Photographing conditions | . Identification (ID) | . Slice planes | . Travel distances | . Time | . Abnormal conditions | . . involving alarms | . Others * | |||||
| EB | EB00 SUPPORTING, MOVING OR FASTENING SUBJECT |
EB01 | EB02 | EB03 | EB04 | EB05 | EB06 | EB07 | EB08 | EB09 | EB10 | |
| . Beds or tables | . . Shapes or materials | . . Supporting mechanisms | . . Moving mechanisms | . . . for vertical movements | . . . for horizontal movements or turnings | . Appliances for supporting or fastening | . Positioning | . Anti-collision or anti-sandwiching | . Others * | |||
| FA | FA00 TESTING, MAINTENANCE, OR MANAGEMENT |
FA01 | FA02 | FA03 | FA04 | FA05 | FA06 | FA07 | ||||
| . Reference settings e.g. phantoms | . . for testing spatial resolutions | . . for testing spatial distortions | . . for testing homogeneities or signal to noise ratios | . . for slice widths | . . Structures or materials | . . Arrangements | ||||||
| FA11 | FA12 | FA13 | FA20 | |||||||||
| . Maintenances or managements | . . of cooling agents in cryostats | . . of cooling water for resistive electromagnets | . Others * | |||||||||
| FB | FB00 SAFETY OR PROTECTION |
FB01 | FB02 | FB03 | FB04 | FB05 | FB06 | FB07 | FB09 | FB10 | ||
| . against subjects' absorption of RF powers | . against heat of metals caused by RF currents | . against attraction or repulsion of magnetic materials | . against evaporation of cooling agents | . . monitoring oxygen; Warning | . . releasing evaporated gases | . . . Emergency evacuation | . of the apparatus | . Others * | ||||
| FC | FC00 ACCESSORY OR FACILITY |
FC01 | FC02 | FC03 | FC04 | FC05 | FC06 | FC07 | FC09 | FC10 | ||
| . Shielded rooms | . . Walls or ceilings | . . Openings | . . . Entrances | . . . Windows | . . Floors | . . Penetrations | . Monitoring patients | . Communication with patients | ||||
| FC11 | FC12 | FC13 | FC14 | FC16 | FC17 | FC20 | ||||||
| . Cameras for hard copies | . Automatic developing machines | . Printers | . Contrast preparations or syringes | . Operation panels | . . of arrangement or structures of operating units. | . Others * |