F-Term-List

3L092 Compression-type refrigeration machines with reversible cycles
F25B13/00 -13/00,371
F25B13/00@A-13/00@Z;13/00,103;13/00,311-13/00,331;13/00,361;13/00,371 AA AA00
PURPOSE
AA01 AA02 AA03 AA04 AA05 AA06 AA07 AA08 AA09 AA10
. Maintenances or improvement of capabilities . Improvement of efficiency or energy saving . Improvement of comfort . . during rising up . Protection of compressors . . Prevention of overloads . . Prevention of liquid compression . . securing lubrication oils . Prevention of frosting or freezing . Prevention of noise
AA11 AA12 AA13 AA14
. Measures against abnormalities or operation errors . Lifetime extension . Regulation of cooling and heating refrigerant amounts . Others *
BA BA00
CHARACTERISTIC FEATURES IN THE CONSTRUCTION OR ARRANGEMENTS *
BA01 BA02 BA03 BA04 BA05 BA06 BA08
. Refrigerant circuits . . Injection circuits . . . Gas injection circuits . . . Liquid injection circuits . . By-pass circuits . . Combinations with other cycles . Compressors
BA11 BA12 BA13 BA14 BA15 BA16 BA17 BA18 BA19
. Heat exchangers . . Indoor heat exchangers . . . Multiple . . . . Dehumidification . . Outdoor heat exchangers . . Auxiliary heat exchangers . . . Heat accumulators . . . Supercoolers . . . Superheaters
BA21 BA23 BA25 BA26 BA27 BA28 BA30
. Refrigerant containers . Pressure-reducing means or expansion valves . Valves . . Switching valves or four-way valves . . Open and close valves or by-pass valves . . Flow regulating valves . Fans
CA CA00
SPECIAL HEAT SOURCES DURING HEATING *
CA01 CA02 CA03 CA04
. Combustion devices . Electric heaters . Solar heat . Use of waste heat
DA DA00
CONTROL TIMING *
DA01 DA02 DA03 DA04 DA06 DA07 DA08 DA10
. during heating . during defrosting . during cooling . during dehumidifying . during starting cycles . . before starting . . after starting . during cycle stops
DA11 DA12 DA14 DA15 DA16 DA17 DA19
. . before stopping . . after stopping . during cycle operations . . during load varying . . during overload . . during low load . during cycle switching
EA EA00
DETECTED OBJECTS *
EA01 EA02 EA03 EA04 EA05 EA06 EA07 EA09 EA10
. Refrigerants . . Temperature pressure or heat exchanger temperature . . . High-pressure sides . . . . Rate of supercooling . . . Low-pressure sides . . . . Rate of superheating . . Liquid levels . Compressors . . Temperature
EA11 EA14 EA15 EA16 EA18 EA20
. . Currents voltages or revolutions . Atmospheric temperature humidity water temperature or brine temperature . . Indoor sides . . Outdoor sides . Time . Operation modes
FA FA00
CONTROLLED OBJECTS *
FA01 FA02 FA03 FA04 FA05 FA06 FA07 FA08 FA09 FA10
. Compressors . . Starting and stopping . . Capabilities . . . Revolutions . . . . Inverters . . . . Pole changing . . . . Voltages or currents . . . Release . . . Bidirectional revolutions . . Multiple compressors or multiple cylinders
FA11 FA12 FA13 FA15 FA16 FA17 FA19 FA20
. Indoor heat exchangers . . Heat-transfer area . . Cooling water or brine flow . Outdoor heat exchangers . . Heat-transfer area . . Cooling water or brine flow . Indoor fans . Outdoor fans
FA21 FA22 FA23 FA24 FA26 FA27 FA28 FA30
. Valves . . Switching valves four-way valves . . Open and close valves or by-pass valves . . Flow regulating valves . Pressure-reducing means or expansion valves . . Motor driven expansion valves . . Bidirectional expansion valves . Injection
FA31 FA32 FA34 FA36
. . Gas injection . . Liquid injection . Refrigerant compositions . Operating sequences
F25B13/00,104 GA GA00
PURPOSE
GA01 GA02 GA03 GA04 GA05 GA06 GA07 GA08 GA09 GA10
. Refrigerant distribution to multiple heat exchangers . Regulation of refrigerant flow in heat exchangers . Regulation of refrigerant amounts . Protection for compressors . Measures against abnormalities or prevention of operation errors . Prevention of noise . Prevention of frosting or freezing . Downsizing of devices or facilitation of installation . Improvement of comfort . Improvement of efficiency or energy saving
GA11 GA12
. Maintenance or improvement of capabilities . Others *
HA HA00
CHARACTERISTIC FEATURES IN THE CONSTRUCTION OR ARRANGEMENTS *
HA01 HA02 HA03 HA04 HA05 HA06 HA07 HA08 HA09 HA10
. Circuits simultaneously operating for cooling and heating . Heat exchangers specially adapted for heating . . Heat exchangers for supplying hot water . Pipeline connection systems for indoor and outdoor units . Heat exchanger passages . Freezing prevention circuits . Refrigerant amount regulating circuits . . Liquid accumulation prevention circuits . Injection circuits . By-pass circuits
HA11 HA12 HA13 HA14
. . High-pressure release circuits . Pressure-reducing means or expansion valves . Refrigerant distribution means . Electrical connection systems of indoor and outdoor units
JA JA00
CONTROL TIMING *
JA01 JA02 JA03 JA04 JA05 JA06 JA07 JA08 JA09 JA10
. during heating . during defrosting . during cooling . during dehumidifying . when increasing or decreasing the number of operating indoor units . . when increasing . . when decreasing . during cycle starting and stopping . . during starting . . during stopping
JA11 JA12 JA13 JA14
. when increasing or decreasing the capabilities of compressors . . when increasing . . when decreasing . during steady operations
KA KA00
DETECTED OBJECTS *
KA01 KA02 KA03 KA04 KA05 KA06 KA07 KA08 KA09 KA10
. Refrigerants . . Temperature pressure or heat exchanger temperature . . . High-pressure sides . . . . Rates of supercooling . . . Low-pressure sides . . . . Rates of superheating . . Liquid levels . Compressors . . Temperature . . Currents voltages or revolutions
KA12 KA13 KA14 KA15 KA16 KA17
. Atmospheric temperature humidity water temperature or brine temperature . . Indoor sides . . Outdoor sides . Number of operating indoor units . Time . Operation modes
LA LA00
CONTROLLED OBJECTS *
LA01 LA02 LA03 LA04 LA05 LA06 LA07 LA08
. Valves . . Switching valves or four-way valves . . Open and close valves or by-pass valves . . Flow regulating valves . Pressure-reducing means or expansion valves . . Motor-driven expansion valves . Capacities of compressors . Capacities of outdoor heat exchangers
F25B13/00,341 MA MA00
HEAT SOURCES *
MA01 MA02 MA03 MA04
. Combustion devices . Electric heaters . Solar heat . Use of waste heat
NA NA00
CHARACTERISTIC FEATURES IN THE CONSTRUCTION OR ARRANGEMENTS *
NA01 NA02 NA03
. Refrigerant circuits . . Injection circuits . . By-pass circuits
NA11 NA12 NA13 NA14 NA16
. Refrigerant heaters . . in series with outdoor heat exchangers . . . by-passing the outdoor heat exchangers . . in parallel with the outdoor heat exchangers . heating the outdoor heat exchangers
PA PA00
CONTROL *
PA01 PA03 PA05 PA07 PA09
. Capacities of compressors . Pressure-reducing means or expansion valves . Injection circuits . Refrigerant amount regulation using containers . Refrigerant recovery operations
PA11 PA13 PA15
. Heat sources . during starting and stopping . Circulation pumps
F25B13/00,351 TA TA00
PURPOSE
TA01 TA02 TA03 TA04 TA05 TA06 TA07 TA08 TA09 TA10
. Prevention of refrigerant stagnation . for only accumulating heat or cold heat . Improvement of performance of rise up operations . . during heating . . during cooling . Improvement of performances during switching operations . Maintenance or improvement of capacities . . Heating capacities . . Cooling capacities . . Defrosting capabilities
TA11 TA12 TA13 TA14 TA15 TA16 TA17 TA18 TA19 TA20
. Improvement of recovery efficiency of accumulated heat or cold heat . Simplification or downsizing of constructions . Improvement of comfort . Protection for apparatus . . Compressors . Levelling of electric power . Measures against or prevention of abnormal conditions . Prevention of noise or vibrations . Improvement of safety . Others *
UA UA00
CONSTRUCTION OR ARRANGEMENTS *
UA01 UA02 UA03 UA04
. Heat or cold heat accumulation circuits . . common to heat recovery coils . . independent of heat recovery coils . . By-pass circuits for accumulating heat or cold heat
UA11 UA12 UA13 UA14 UA15
. Auxiliary heat sources . . Combustion devices . . Electric heaters . . Solar heat . . Use of waste heat
UA21 UA22 UA24 UA25 UA26
. Hot-water supply circuits . . Hot-water supply tanks . having a plurality of closed circuits . . One closed circuit without phase change . . A plurality of closed circuits being in parallel
UA31 UA33 UA34 UA35 UA36
. Heat accumulation tanks or vessels . Heat or cold heat accumulation materials * . . Water or ice . . Chemical agents * . . Additives *
VA VA00
HEAT OR COLD HEAT ACCUMULATION TIMING *
VA01 VA02 VA03 VA04 VA06 VA07 VA08
. Heat accumulation . . Operations specially adapted for heat accumulation . . . Hot water heating and storing . . Simultaneous operations of heat accumulation and loaded operations . Cold heat accumulation . . Operations specially adapted for cold heat accumulation . . Simultaneous operations of cold heat accumulation and loaded operations
WA WA00
ACCUMULATED HEAT OR COLD HEAT RECOVERY TIMING *
WA01 WA02 WA03 WA04 WA05 WA07 WA08
. during heating . . using outdoor heat exchangers or heating . . . Heating in series . . . heating in parallel . . Not using the outdoor heat exchangers for heating . . during rising up for heating . . during high load for heating
WA11 WA12 WA13 WA14 WA15 WA17 WA18
. during cooling operations . . using outdoor heat exchangers for cooling . . . Cooling in series . . . cooling in parallel . . not using outdoor heat exchangers for cooling . . during rising up for cooling . . during high load for cooling
WA21 WA22 WA23 WA25 WA26
. during defrosting . . Operations specially adapted for defrosting . . simultaneously performing defrosting and heating . . Defrosting by reverse the cycles . . Hot gas by-pass defrosting
XA XA00
DETECTED OBJECTS *
XA01 XA02 XA03 XA04 XA05 XA06 XA07 XA08 XA09
. Refrigerant temperatures . . Temperatures at high-pressure sides . . . Temperatures during heating . . . Temperatures during cooling . . . Temperatures during defrosting . . Temperatures at low-pressure sides . . . Temperatures during heating . . . Temperatures during cooling . . . when defrosting temperatures
XA11 XA12 XA13 XA14 XA15 XA16 XA17 XA18 XA19
. Refrigerant pressures . . Pressures at high-pressure sides . . . Pressures during heating . . . Pressures during cooling . . . Pressures during defrosting . . Pressures at low-pressure sides . . . Pressures during heating . . . Pressures during cooling . . . Pressures during defrosting
XA21 XA23 XA25 XA27 XA28 XA29
. Indoor temperatures . Outdoor temperatures . Brine temperatures . Heat accumulation tanks or vessels . . Temperatures . . Liquid levels
XA31 XA32 XA33 XA40
. Compressors . . Currents or voltages . . Number of revolutions . Time
YA YA00
CONTROLLED OBJECTS *
YA01 YA03 YA05 YA06 YA07 YA09
. Compressors . External heating and cooling sources . Heat exchangers . . indoor . . outdoor . Fans
YA11 YA12 YA13 YA14 YA16 YA18 YA20
. Valves . . Switching valves or multiple-way valves . . Open and close valves or by-pass valves . . Flow rate regulating valves . Pressure-reducing means expansion valves . Pumps . Time
TOP