This page displays all 「FI」 in main group G01R23/00. |
HB:Handbook | ||||
CC:Concordance |
|
Arrangements for measuring frequencies; Arrangements for analysing frequency spectra | HB | CC | 2G029 | |
|
.Arrangements for measuring frequency, e.g. pulse repetition rate; Arrangements for measuring period of current or voltage | HB | CC | 2G029 | |
|
..adapted for measuring in circuits having distributed constants | HB | CC | 2G029 | |
|
Hollow resonator type frequency meters | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
..by converting frequency into an amplitude of current or voltage | HB | CC | 2G029 | |
|
Converting and smoothening input signal into signals with a certain width | HB | CC | 2G029 | |
|
.Using of monostable multi vibrators | HB | CC | 2G029 | |
|
.Using of saturable reactors | HB | CC | 2G029 | |
|
.Using of counters | HB | CC | 2G029 | |
|
.Using of charging and discharging circuits | HB | CC | 2G029 | |
|
.With hysteresis characteristics, circuits for adjusting time constants, frequenfy multiplier circuits, range switching circuits, bias application circuits, ripple removing characteristics (range switching in general 15/08) | HB | CC | 2G029 | |
|
Using of counting circuits, shift resisters or PLL | HB | CC | 2G029 | |
|
Characterised by meter driving circuits | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
...using response of circuits tuned on resonance, e.g. grid-drip meter [2] | HB | CC | 2G029 | |
|
...using response of circuits tuned off resonance | HB | CC | 2G029 | |
|
...using analogue integrators, e.g. capacitors establishing a mean value by balance of input signals and defined discharge signals or leakage [2] | HB | CC | 2G029 | |
|
Smoothening charging and discharging current of condensers | HB | CC | 2G029 | |
|
Sampling and holding integrated outputs of condensers | HB | CC | 2G029 | |
|
Smoothening integrated outputs of condensers | HB | CC | 2G029 | |
|
Integrating differences from datum frequencies; obtaining frequency differences | HB | CC | 2G029 | |
|
With function generators, converting circuits for integrated outputs or control circuits for integrating circuits | HB | CC | 2G029 | |
|
With multiple integrating circuits | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
..by converting frequency into a train of pulses, which are then counted | HB | CC | 2G029 | |
|
Measuring frequencies | HB | CC | 2G029 | |
|
Measuring frequencies; with circuits for converting from period to frequency and vise versa | HB | CC | 2G029 | |
|
Correcting quantisation errors | HB | CC | 2G029 | |
|
Synchronising input signals and gate pulses | HB | CC | 2G029 | |
|
Range switching circuits; switching period and frequency measurements (range switching in general 15/08) | HB | CC | 2G029 | |
|
With delay circuits, shift resistors | HB | CC | 2G029 | |
|
Characterised by frequency multiplication or division circuits | HB | CC | 2G029 | |
|
Measuring frequency deviations, ratios or changes | HB | CC | 2G029 | |
|
Measuring received frequencies | HB | CC | 2G029 | |
|
With structures for preventing blurring of indications or testing (testing, calibrating 35/00) | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
..by converting frequency into phase shift | HB | CC | 2G029 | |
|
..by heterodyning; by beat-frequency comparison [2] | HB | CC | 2G029 | |
|
Measuring frequencies of outputs after converting frequencies | HB | CC | 2G029 | |
|
.With sweep frequency local resonators | HB | CC | 2G029 | |
|
.With circuits for controlling local resonators | HB | CC | 2G029 | |
|
Detecting specific frequency constituents contained in outputs after converting frequencies | HB | CC | 2G029 | |
|
Detecting zero beating | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
..Indicating that frequency of pulses is either above or below a predetermined value or within or outside a predetermined range of values, by making use of non-linear or digital elements [3] | HB | CC | 2G029 | |
|
Using of integrating circuits | HB | CC | 2G029 | |
|
Using of counters | HB | CC | 2G029 | |
|
.Counting frequencies | HB | CC | 2G029 | |
|
.Counting periods | HB | CC | 2G029 | |
|
.With hysteresis characteristics; testing judging arrangements, monitoring abnormalities | HB | CC | 2G029 | |
|
.Comparing multiple input signals | HB | CC | 2G029 | |
|
Using of monostable circuits | HB | CC | 2G029 | |
|
.Detecting outputs from monostable circuits | HB | CC | 2G029 | |
|
.Comparing periods subject to measurements and outputs of monostable circuits | HB | CC | 2G029 | |
|
.With hysteresis characteristics; monitoring abnormalities | HB | CC | 2G029 | |
|
Using of filters | HB | CC | 2G029 | |
|
Comparing F-V converted outputs with datum values | HB | CC | 2G029 | |
|
Comparing multiple input signals | HB | CC | 2G029 | |
|
.Using of shift resistors | HB | CC | 2G029 | |
|
.Using of bistable circuits | HB | CC | 2G029 | |
|
Determining by computers | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
.Spectrum analysis; Fourier analysis | HB | CC | 2G029 | |
|
Using of Fourier transformations | HB | CC | 2G029 | |
|
.Using of FFT, Haar transformations | HB | CC | 2G029 | |
|
Using of correlating, auto-regressive models, frequency dispersions, litharge, synchronous detection or digital differentiating analyses | HB | CC | 2G029 | |
|
Characterised by pre-processing of analysed signals or processing of analytical results | HB | CC | 2G029 | |
|
Characterised by indications | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
..adapted for measuring in circuits having distributed constants [3] | HB | CC | 2G029 | |
|
..using filters [3] | HB | CC | 2G029 | |
|
Using single filters only | HB | CC | 2G029 | |
|
Using multiple filters | HB | CC | 2G029 | |
|
.Characterised by indicating units | HB | CC | 2G029 | |
|
.Indicating whole band widths | HB | CC | 2G029 | |
|
Using of comb filters; calibrating, testing | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
...with digital filters [3] | HB | CC | 2G029 | |
|
..with optical auxiliary devices [3] | HB | CC | 2G029 | |
|
..Wobbulating devices similar to swept panoramic receivers [3] | HB | CC | 2G029 | |
|
Switching or magnifying sweep ranges or switching ranges | HB | CC | 2G029 | |
|
Characterised by local resonators; with tracking signal generators | HB | CC | 2G029 | |
|
Indicating markers | HB | CC | 2G029 | |
|
Calibrating; correcting errors; removing images; protecting circuits | HB | CC | 2G029 | |
|
Measuring phase of analysed outputs also | HB | CC | 2G029 | |
|
Measuring frequencies of particular analyses positions | HB | CC | 2G029 | |
|
Selection level meters | HB | CC | 2G029 | |
|
Monitoring and analysing radio waves | HB | CC | 2G029 | |
|
Characterised by processing, memorizing or indicating of analysed outputs | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |
|
..by delay means, e.g. tapped delay lines [3] | HB | CC | 2G029 | |
|
..Analysis of very low frequencies [3] | HB | CC | 2G029 | |
|
..with provision for recording frequency spectrum | HB | CC | 2G029 | |
|
..Measurement of non-linear distortion | HB | CC | 2G029 | |
|
Measurement of strain ratios | HB | CC | 2G029 | |
|
.Characterised by circuits for removing fundamental waves | HB | CC | 2G029 | |
|
Measurement of respective harmonic compositions | HB | CC | 2G029 | |
|
Measurement of modulation strain | HB | CC | 2G029 | |
|
Measurement of strain for circuits to be measured | HB | CC | 2G029 | |
|
Others | HB | CC | 2G029 | |