This page displays all 「FI」 in main group F28F9/00. |
HB:Handbook | ||||
CC:Concordance |
|
Casings; Header boxes; Auxiliary supports for elements; Auxiliary members within casings | HB | CC | 3L065 | |
|
pipe vibration prevention (by supports 9/00 311) | HB | CC | 3L065 | |
|
removal of non-condensed gas (air) | HB | CC | 3L065 | |
|
mounting of shrouds | HB | CC | 3L065 | |
|
mounting of electrical parts (sensors, etc.) | HB | CC | 3L065 | |
|
grids, filters; mounting of them | HB | CC | 3L065 | |
|
Others | HB | CC | 3L065 | |
|
.installation of heat exchangers | HB | CC | 3L065 | |
|
.bodies of heat exchangers | HB | CC | 3L065 | |
|
.Auxiliary supports for elements | HB | CC | 3L065 | |
|
..for tubes or tube-assemblies | HB | CC | 3L065 | |
|
support for parallel pipe (F28F9/013J takes precedence) | HB | CC | 3L065 | |
|
.by through hole formed in support plate | HB | CC | 3L065 | |
|
..have intermediate member, e.g. sleeve, elastic body, inside support plate | HB | CC | 3L065 | |
|
.by fitting groove formed on support member | HB | CC | 3L065 | |
|
..holding pipe between support member | HB | CC | 3L065 | |
|
.holding pipe between parallel support member (F28F9/013E takes precedence) | HB | CC | 3L065 | |
|
..support member crossing, e.g. latticed | HB | CC | 3L065 | |
|
.by cylindrical spacer inserted in pipe | HB | CC | 3L065 | |
|
mutually supporting pipe by welding or bonding | HB | CC | 3L065 | |
|
peculiar to support of bend portion of pipe | HB | CC | 3L065 | |
|
Others | HB | CC | 3L065 | |
|
.Header boxes; End plates | HB | CC | 3L065 | |
|
floating pipe plates | HB | CC | 3L065 | |
|
mounting of pipe plates (A takes precedence) | HB | CC | 3L065 | |
|
.using sealing materials | HB | CC | 3L065 | |
|
pipe plates being cylindrical or spherical | HB | CC | 3L065 | |
|
partition structure | HB | CC | 3L065 | |
|
arrangement and mounting of valves | HB | CC | 3L065 | |
|
easing of the thermal stress of pipe plates | HB | CC | 3L065 | |
|
.by cooling or heating | HB | CC | 3L065 | |
|
pipe leakage detection | HB | CC | 3L065 | |
|
Others | HB | CC | 3L065 | |
|
..heat exchangers having an assembled body of stationary flow paths only for one heat exchange medium that media touch flow paths on the different sides and other heat exchange media are fluids of a large amount, e.g. used for domestic or automobile radiators | HB | CC | 3L065 | |
|
joint of pipe plates and tanks | HB | CC | 3L065 | |
|
.via packings | HB | CC | 3L065 | |
|
pipe plates and tanks being formed together | HB | CC | 3L065 | |
|
partition structure | HB | CC | 3L065 | |
|
connection of tanks and flow-in (out) pipes (J takes precedence) | HB | CC | 3L065 | |
|
arrangement and mounting of valves | HB | CC | 3L065 | |
|
arrangement and mounting of heat exchangers in the tank (lubricants, arrangement of coolers F01P) | HB | CC | 3L065 | |
|
ejection of drain | HB | CC | 3L065 | |
|
intrinsic to the laminated type | HB | CC | 3L065 | |
|
Others | HB | CC | 3L065 | |
|
..Arrangements for sealing elements into header boxes or end plates (joining pipes to walls in general F16L 41/00) | HB | CC | 3L065 | |
|
...by dismountable joints | HB | CC | 3L065 | |
|
....by wedge-type connections, e.g. taper ferrule | HB | CC | 3L065 | |
|
....by screw-type connections, e.g. gland | HB | CC | 3L065 | |
|
....by flange-type connections | HB | CC | 3L065 | |
|
....by force-joining | HB | CC | 3L065 | |
|
...by permanent joints, e.g. by rolling (metal-working procedures in general B21, B23, particularly B21D 39/06, B23K) | HB | CC | 3L065 | |
|
....by welding | HB | CC | 3L065 | |
|
.Arrangements of heat reflectors, e.g. separately-insertible reflecting walls | HB | CC | 3L065 | |
|
.Arrangements for directing heat-exchange media into successive compartments, e.g. arrangements of guide plates | HB | CC | 3L065 | |
|
.Arrangements for promoting turbulent flow of heat-exchange media, e.g. by plates (F28F 1/38 takes precedence; in general F15D) | HB | CC | 3L065 | |
|
.Arrangements for connecting different sections of heat-exchange elements, e.g. of radiators (connecting different sections in water heaters F24H 9/14) | HB | CC | 3L065 | |