This page displays all 「FI」 in main group A61B3/00. |
HB:Handbook | ||||
CC:Concordance |
|
Apparatus for testing the eyes; Instruments for examining the eyes (eye inspection using ultrasonic, sonic or infrasonic waves A61B 8/10; optical systems per se G02B) | HB | CC | 4C316 | |
|
.Testing apparatus able to be adjusted according to statements of the patient, e.g. for determining perimeters | HB | CC | 4C316 | |
|
..for determining the visual field, e.g. perimeter types | HB | CC | 4C316 | |
|
..for testing visual acuity; for determination of refraction, e.g. phoropters | HB | CC | 4C316 | |
|
...Rotatable lens; rotatable lens disks | HB | CC | 4C316 | |
|
...Devices for presenting test symbols or characters, e.g. test chart projectors(A61B3/036 takes precedence) | HB | CC | 4C316 | |
|
...for testing astigmatism | HB | CC | 4C316 | |
|
...Trial frames; Sets of lenses for use therewith (lenses per se G02C 7/02) | HB | CC | 4C316 | |
|
..for testing light sensitivity, e.g. adaptation; for testing colour vision | HB | CC | 4C316 | |
|
..for testing binocular or stereoscopic vision, e.g. strabismus | HB | CC | 4C316 | |
|
..for testing accommodation | HB | CC | 4C316 | |
|
.Objective types, i.e. instruments for examining the eyes independent of the patients perceptions or reactions | HB | CC | 4C316 | |
|
..Optical Coherence Tomography [OCT] | HB | CC | 4C316 | |
|
..Scanning Laser Ophthalmoscopy [SLO] | HB | CC | 4C316 | |
|
..Electromagnetic inspection | HB | CC | 4C316 | |
|
..Measurement using ultrasonic wave | HB | CC | 4C316 | |
|
..for determining refraction, e.g. refractometers, skiascopes | HB | CC | 4C316 | |
|
..for determining the shape or measuring the curvature of the cornea | HB | CC | 4C316 | |
|
..for measuring interpupillary distance or diameter of pupils | HB | CC | 4C316 | |
|
..for measuring interpupillary distance or diameter of pupils | HB | CC | 4C316 | |
|
..for examining the anterior chamber or the anterior chamber angle, e.g. gonioscopes | HB | CC | 4C316 | |
|
..for looking at the eye fundus, e.g. ophthalmoscopes (A61B 3/13 takes precedence) | HB | CC | 4C316 | |
|
...Blood flow at the ocular fundus | HB | CC | 4C316 | |
|
...with contact lenses | HB | CC | 4C316 | |
|
..Ophthalmic microscopes | HB | CC | 4C316 | |
|
...Cornea endothelium inspection | HB | CC | 4C316 | |
|
...Slit-lamp microscopes | HB | CC | 4C316 | |
|
..with means for attaching cameras thereto | HB | CC | 4C316 | |
|
...with means for aligning, spacing or blocking spurious reflection | HB | CC | 4C316 | |
|
..for measuring intraocular pressure, e.g. tonometers | HB | CC | 4C316 | |
|
...Non-contact tonometers | HB | CC | 4C316 | |
|
.Arrangement of plural eye-testing or -examining apparatus | HB | CC | 4C316 | |